Koehler KV4000 Скачать руководство пользователя страница 7

KV4000 Kinematic Viscosity Bath 
Operation and Instruction Manual 

 

KV4000-Manual 

3 -

 

WEEE Directive Compliance Statement 

 

Background 

The  goal  of  the  WEEE  Directive  is  to  encourage  design  of  environment-friendly  products  that 
increase  reuse,  recycling  and  other  forms  of  recovery  to  reduce  waste  streams  and  applies  to 
listed  Electronic  and  Electrical  Equipment  (EEE)  and  Koehler's  equipment  falls  broadly  into 
Appendix  1A;  Section  9  Monitoring  and  Control  Equipment:  Measuring,  weighing  or  adjusting 
appliances for household or as laboratory equipment. 
 
Any associated non-embedded equipment such as Lighting (Saybolt Color) and PCs/Printers also 
fall under WEEE.  If provided with an order these ancillary items must be WEEE compliant.  For 
these  and  other  reasons  (printer  cartridges  are  regionalized)  the  equipment  must  be  supplied 
through a third party supplier in Europe. 
 
The  WEEE  Directive  applies  to  electrical  and  electronic  equipment  falling  under  the  categories 
set  out  in  Annex  IA  provided  that  the  equipment  concerned  is  not  part  of  another  type  of 
equipment  that  does  not  fall  within  the  scope  of  this  Directive.  Annex  IB  contains  a list  of 
products which fall under the categories set out in Annex IA.   
 
http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2003:037:0024:0038:en:PDF 
 
We do not qualify for any of the 10 exemption categories. 
http://www.dpa-system.dk/en/WEEE/Products/Exemptions 

 

Professional use 

For equipment defined for ’professional use’ local authorities have no role to play. Producers and 
importers are basically responsible for collection of WEEE recyclables from the professional user 
and  for  subsequent  management.      A  separate  statement

 

is  given  cataloging  the  items  that 

require separation from the equipment along with basic information on subsequent processing or 
recycling prior to disposal of the equipment. 
http://www.dpa-system.dk/en/WEEE/Products/Private-or-professional-use 

 

Responsibility for Registration and Annual Reporting:   

Koehler will not sell directly to end users in the EU and so has no responsibility to register within 
each EU state and to make annual reports. Koehler declares that this responsibility is born by the 
importer  who  is  the  first  level  of  the  distribution  chain  and  is  subject  to  producer  responsibility.  
We  will  communicate  this  in  writing  to  our  distributor/importers  in  the  EU  stating  they  are 
responsible to satisfy WEEE registration and reporting requirements in the EU states where they 
conduct sales activities. 
 
It  is  illegal  to  market  electrical  and  electronic  equipment  covered  by  producer  responsibility 
without being registered. 
 
http://www.dpa-system.dk/en/WEEE/Producers/Whoissubjecttoproducerresponsibility 

 

Product Design 

Koehler's  designs  allow  for  complete  disassembly  to  a  modular  level  which  usually  allows  for 
standard  recycling.    A  qualified  refrigeration  system  technician  must  be  consulted  when 
disassembling and de-commissioning any equipment with refrigeration systems. 
 
Koehler's scientific testing equipment is robustly designed to function over a long service  life and 
are  typically  repaired  many  times  over  the  course  of  years  rather  than  being  replaced.    We 
believe that re-use and refurbishment is the very best form of re-cycling.   
 
All batteries must be readily removable not soldered in place. 

 

Recycling instructions 

In the  event that  replacement  becomes  necessary,  we  will  include  instructions,  particularized  to 
each  instrument  that  informs  the  customer  of  their  recycling  responsibilities  and  giving  them 

Содержание KV4000

Страница 1: ...re Avenue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Anal...

Страница 2: ......

Страница 3: ...e with the applicable standards set forth in this certification Specifications ASTM D445 ASTM D2532 ASTM D6074 ASTM D6158 IP 71 ISO 3104 DIN 51550 FTM 791 305 NF T 60 100 This unit is tested before it...

Страница 4: ......

Страница 5: ...KV4000 Kinematic Viscosity Bath Operation and Instruction Manual KV4000 Manual 1...

Страница 6: ...KV4000 Kinematic Viscosity Bath Operation and Instruction Manual KV4000 Manual 2...

Страница 7: ...rate statement is given cataloging the items that require separation from the equipment along with basic information on subsequent processing or recycling prior to disposal of the equipment http www d...

Страница 8: ...1716 As a minimum the following substances preparations and components have to be removed from any separately collected WEEE Mercury containing components such as switches or backlighting lamps compac...

Страница 9: ...unning Tests 11 4 3 Temperature Controller Operation 13 5 Operation 14 5 1 Bath 14 5 2 Start Up 15 5 3 Control Panel Operation 15 5 4 Test Procedure 17 6 Safety Features 18 6 1 Over Temperature Protec...

Страница 10: ...cosity Bath Operation and Instruction Manual KV4000 Manual 6 9 Wiring Diagrams 22 9 1 K23702 K23708 115 V Wiring 22 9 2 K23792 K23798 220V Wiring 23 10 Service 24 11 Storage 24 12 Warranty 24 13 Retur...

Страница 11: ...rate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests or technical suppor...

Страница 12: ...for use in accordance with the applicable standard test methods listed in section 1 2 of this manual The use of this equipment in accordance with any other test procedures or for any other purpose is...

Страница 13: ...ment from cart and place on bench 8 Remove foam insert Borosilicate Glass Jar as per steps 9 thru 19 9 Using a flat head screwdriver remove the four 4 silver screws located at the four corners of the...

Страница 14: ...s to these during normal operation can shatter the glass components releasing the bath fluid posing thermal burn hazards and slipping hazards For this reason the instrument must be operated by and acc...

Страница 15: ...y is placed into the bath through the viscometer ports on top of the instrument 7 Bath Bath Stirrer The stirrer constantly circulates bath medium to prevent temperature gradients and ensures temperatu...

Страница 16: ...nt at all temperatures This is advantageous when samples are to be measured at different temperatures Suspended level type viscometers are for transparent liquids of up to 100 000cSt Requires a sample...

Страница 17: ...ase the set point temperature and to increase or change parameter values when programming the temperature controller 6 Exit Function Key This key is used to exit or leave a level One level backward IM...

Страница 18: ...ed for performing kinematic viscosity tests using glass capillary viscometers Please be sure to read the safety and hazard warnings the installation procedure and any of the standard test methods befo...

Страница 19: ...matches that of the ASTM Thermometer Calibrate if necessary See Section 4 3 for full operational details of the temperature controller 5 3 Control Panel Operation Figure 3 Control Panel_Main Screen 1...

Страница 20: ...an be found on the calibration certificate provided with the viscometer 5 Constant 2 Press the Constant 2 button to input a second viscometer tube constant value using the pop up numerical keypad A se...

Страница 21: ...uum system to the initial testing position above the first line This is also called charging the viscometer Place stopper in the top of the viscometer tube and remove the withdrawal bulb NOTE The proc...

Страница 22: ...KV4000 Kinematic Viscosity System is equipped with several safety and protection features which are described in the following sections WARNING The bath is NOT Explosion Proof 6 1 Over Temperature Pro...

Страница 23: ...tenance WARNING Disconnect power to the unit before servicing to avoid exposure to high voltages and or temperatures which may result in personal injury or death If you have any questions about mainta...

Страница 24: ...move the four 4 silver screws located at the four corners of the back panel 7 Remove the back panel plate and set aside 8 A collection of wires runs from the lower control panel up the left side while...

Страница 25: ...lacement Parts Part Number Description 050 001 028 Single Pole Switch 15A 091 032 001 Solid State Relay 4 32 VDC 20A 275 103 036 RTD Temperature Safety Limit 120V 275 103 037 RTD Temperature Safety Li...

Страница 26: ...KV4000 Kinematic Viscosity Bath Operation and Technical Manual KV4000 Manual 22 9 Wiring Diagrams 9 1 K23702 K23708 115 V Wiring...

Страница 27: ...KV4000 Kinematic Viscosity Bath Operation and Technical Manual KV4000 Manual 23 9 2 K23792 K23798 220V Wiring...

Страница 28: ...rn of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or re...

Страница 29: ...KV4000 Kinematic Viscosity Bath Operation and Technical Manual KV4000 Manual 25 Notes...

Страница 30: ...KV4000 Kinematic Viscosity Bath Operation and Technical Manual KV4000 Manual 26 Notes...

Отзывы: