9
CAUTION: Never allow the pressure washer to run for
more than 3 minutes with the gun closed and the motor
running. Prolonged operation in bypass mode can result
in damage to the pump.
NOTE: Always shut the motor OFF and engage the gun
safety-lock when the pressure washer is not in use.
CAUTION: Failure to discharge the residual pressure could result in personal
injury due to discharge of high-pressure water.
STEP 3
Turn OFF the water supply.
STEP 1
Turn motor switch off.
STEP 2
Unplug power cord from outlet.
STEP 6
Disconnect the garden hose from
the water INLET.
STEP 5
Disconnect the high-pressure hose
from the water OUTLET.
STEP 4
Discharge residual pressure by
pressing and holding the gun
trigger until no water comes out
the nozzle.
STEP 7
Engage the safety-lock.
THERMAL PROTECTION VALVE
Your pressure washer is equipped with a thermal protection valve, located at the base of the pump. If the motor is left
running for an extended period of time with the gun closed, the pressure washer will vent water into the atmosphere
through this valve. This will protect against accidental situations but is not designed for repetitive venting.