Chapter 1 Installation
CVS-872D
1-58
0092607062-01
1.5.2 Connection of Hemisphere V104s GPS Compass
Connect CW-376-5M by soldering with the cable of Hemisphere V104s GPS Compass.
Please prepare two CW-376-5M when connecting with Radar as GPS compass.
1) The terminal of the cables of V104s GPS Compass is not processed, and 8 lead wires and
1 shield wire are open. Orange and violet lead wires are connected to TX/RX of Port A,
blue and green lead wires are connected to TX/RX of Port B, black and red lead wires are
connected to +/- of power supply, and brown lead wire is connected with earth. Yellow lead
wire and shield wire are unconnected.
Refer to the
“Connection table of V104s GPS Compass”
, and solder CW-376-5M with
Port A and power supply of cable of Hemisphere V104s GPS Compass. Please solder
another CW-376-5M with Port B, when connecting with Radar as GPS compass. Please
branch brown wire (GND) of the cable of V104s GPS Compass into four, two of which shall
be soldered with each black (RX-) and red (TX-) of CW-376-5M. After soldering is
completed, be sure to process the connected part by self-adhesive tape etc. to be water
resistant and insulated.
Fig. 1.53 Connection of V104s GPS Compass
CW-376-5M
Cable of V104s GPS Compass
Blue and shield
White
Orange
Green
Red
Black
Red
Black
White
Orange
Black
Orange
Violet
Red
Brown
Brown
Brown
Brown
Blue
Green
Yellow
Shield
To NMEA terminal of Radar
CW-376-5M
Solder
e
d
To J3 connector of
CVS-872D
Port A/Power
Port B
Yellow wire is branched into 4.
Unconnected
Solder
e
d