4-2
A-61816 April 2014
Cleaning procedures
Your scanner needs to be cleaned periodically. If your documents do
not feed easily, if several documents feed at the same time or if streaks
appear on your images, it is time to clean your scanner. The section
entitled, “Supplies and consumables” at the end of this chapter
provides a listing of the supplies required to clean your scanner.
IMPORTANT: Only use cleaners such as those provided through Kodak
Parts Services. Do not use household cleaners.
Allow surfaces to cool to ambient temperature before
use. Do not use cleaners on hot surfaces.
Use adequate ventilation. Do not use cleaners in
confined areas.
NOTES:
• Before cleaning, disconnect the electrical power.
• Wash your hands with soap and water after performing maintenance
procedures.
Cleaning the rollers
1. Open the scanner cover.
2. With a roller cleaning pad, wipe the feed rollers from side to side.
Rotate the feed rollers to clean the entire surface.
IMPORTANT: The roller cleaning pad contains sodium lauryl ether
sulfate which can cause eye irritation. Refer to the MSDS
for more information.
3. Dry the rollers with a lint-free cloth.