Replacements and Installations
SM4530-1 – 30APR96
21
Replacing the LENS MOUNT ASSEMBLY - Non Auto Focus Model
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER
HOUSING ASSEMBLY.
[3] Remove the FOCUS KNOB.
[4] Remove the 3 SCREWS from the LENS MOUNT
ASSEMBLY.
[5] Lift and remove the LENS MOUNT ASSEMBLY.
Installing the LENS MOUNT ASSEMBLY - Non Auto Focus Model
[1] Do the replacement procedure for the LENS MOUNT ASSEMBLY in reverse order.
A100_0019GA
SCREW (3)
ASSEMBLY
LENS MOUNT
A100_0019GCA
Содержание EKTAGRAPHIC III A