Power Distribution
1234563 – 12/12/94
5–23
Electrical Path
Power Distribution Components
S8 INTERLOCK SWITCH
The S8 INTERLOCK SWITCH controls relays on the A1 MSC BD, which in turn controls the 24 V DC power to the the DC components,
including the MOTORS, SOLENOIDS, and the LASER SHUTTER. The S8 is located at the bottom left on the frame and is actuated when
the FRONT DOOR is opened.
T1 TRANSFORMER
The T1 TRANSFORMER receives from
90 to 264 Doug Seim ??
V AC, 50/60 Hz and transfroms it to 120 V AC, 50/60 Hz.
UPS 1 UNINTERRUPTIBLE
POWER SUPPLY
Receives 120 VAC from the T1 TRANSFORMER and distributes it to PS1 as well as to the ERASE AY and the INTERNAL PC.
PS1 DC POWER SUPPLY
This supply has +/-24 V DC and +24 V DC outputs only. It receives 120 V AC from UPS 1 and supplies all the circuit boards, as well as
the PS 2 and the TOUCHSCREEN MONITOR. The ERASE ASSEMBLY is not powered by PS1.
PS 2 LASER HIGH
VOLTAGE POWER
SUPPLY
Supplies 3650 V DC to the 23 mw Class 3B LASER.
Illustration of Power Distribution from wall outlet throughout the CR 800, including the components listed below.