Using the KODAK EKTACOLOR Processing Cartridge 111 with Digital Minilabs, CP-48S/CP-49E
CIS-229E
7
SILVER RECOVERY
Publications on silver management that include
recommendations and descriptions of silver-recovery
options are available in the Silver Management section
of the Kodak Environmental Services Publication Center
at www.kodak.com/go/KES .
DRAINING AND MIXING FRESH
REPLENISHERS
If you need to drain and mix fresh replenisher solutions,
follow this procedure:
1.
Empty the remaining replenisher solutions by using
the drain valves at the bottom of the machine
2.
After draining is complete, close the drain valves.
Note for FUJI FRONTIERS only:
It is necessary to add water to the developer
replenisher tank. Add this instruction to those above:
2A. Pour 500 mL of water into the developer (the slot
farthest to the left) in the cartridge-loading section.
3.
Insert a full cartridge into the slot and make
replenishers by following the standard procedure
given for the processor model used.
Example: Loading dock of FUJI FRONTIER Processor
Note:
If you forget to add the water and receive an error
message (E-2675) when you prepare fresh replenisher, you
can add the water after the replenisher has been mixed. The
water addition is only necessary when the replenisher
tank has been drained; it is not required for routine
mixes with the cartridge.
Pour 500 mL of water into this
position when making replenisher
after completely draining replenisher
tanks.