background image

Cautions for Use

Name of Each Part

1

1

Name

No  

2
3

4

5

6

Abovementioned cases may cause troubles in the product. 

Please be careful to the cautions in use of the product

Key Features

Front View

KCV-801

KCV-801R

2

3

4

5

6

 Do not place the product near humidifier, heater, etc. High temperature and humidity may cause troubles.

 Do not drop, or give a strong impact on, main body and gate camera.

 Do not place the main body near the things emitting strong magnetism (e.g. TV, speaker, etc)

     because it may cause the drift or distortion of screen, resulting in troubles.

 Do not clean the product with wet hands, or use volatile liquids such as benzene or thinner.

 Clean up camera and window part of main body from time to time to keep fine and clear image quality.

 This product is designed as a precision electronic device, so do not disassemble it at user's discretion. 

 7inch Color Lcd (NTSC/PAL Auto Switching)

LED Indication in Conditions

4 melody selection

OSD (On Screen Display) menu control

PIR sensor camera & CCTV camera connection

CCTV monitoring Mode

Built 128 cut images memory (KCV-801R, KCV-D801R)

Auto record in absent mode (KCV-801R, KCV-D801R)

Upto 2 monitor & 2 audio sub phone with 2 cameras connection

Internal call & conversation between extended indoor units

AC Type : KCV-801, KCV-801R / DC Type : KCV-D801, KCV-D801R

Brief Description

Handset

used in communication between camera and extended indoor units.

Cam 1

turns on/off communication and monitoring functions of Camera 1

Cam 2

turns on/off communication and monitoring functions of Camera 2

 Left 

Button

(A) if pressed in standby mode, a stored image is played. (used as Rewind key)

     [KCV-801R, KCV-D801R only]

(B) used as Left button in setting OSD menu.
(A) saves (RECORD) images from Camera 1 & 2 [KCV-801R, KCV-D801R only]

(B) used as Up button in setting OSD menu

(C) sets or cancels the interlocking with PIR camera, if pressed for three seconds   

 Up 

Button

(A) plays images saved in standby mode - used as Forward key [KCV-801R, KCV-D801R only]

(B) used as Right button in setting OSD menu

 Right 

Button

(A) used as Delete key in playing images [KCV-801R, KCV-D801R only]

(B) used as Down button in setting OSD menu

(C) sets or cancels the long-played CCTV images, if pressed for three seconds

 Down 

Button

(A) displays LCD adjustment menu (contrast, brightness and color), 

     if pressed in standby mode for more than one seconds

(B) displays Memory adjustment menu (date and format), if three seconds pressed in Standby mode

     [KCV-801R, KCV-D801R only]

(C) inputs adjusted setups 

Menu/

OK Button

(A) calls extension line when a user picks up handset and presses extension line Button

(B) sets or cancels Absence mode when a user press Extension/Absence button 

     with handset hung up (displayed by LED) [KCV-801R only]

 Extension 

/Absence

works door open function of camera when a user press this button 

with communicating with door camera

         Door 

Open Button

REC

PLAY

PLAY

DEL

/

10

11

2

3

4

5

6

/

or

Cautions for Installation

 This product is designed as a precision electronic device, so do not disassemble it at user's discretion.

 Comply with the specifications provided by KOCOM in installation of the product.

 Do not touch the product with foreign things (e.g. sticker, magnet, bottle opener, iron chopsticks, etc.) 

     and do not bring them in the product. 
     (It may not only shorten the durability of the product but also bring danger to users.)

 During the rainy season, rainwater may flow in the product along its wiring and affect the system. 

     So, the end of wiring is required to finish with letter 'U' type.

 Do not install the door camera in the place under direct sunlight shines, it may make faint image or white stripe or round    

     form line on the image. If this phenomenon appears on the monitor's image, it is not mechanical trouble, so please      
     replace the door camera to keep away direct sunlight or change the direction of the door camera.

Содержание KCV-801

Страница 1: ...s based on the date as shown in the right and specifications are subject to change without notice for quality improvement 7inch LCD Communication with door and door monitoring Door open during communi...

Страница 2: ...onitor Installation 9 Door Camera Installation 9 Components 10 10 11 Key Features Cautions for use Cautions for Installation Name of Each Part 10 12 Specifications 13 14 20 System Diagram Wiring Diagr...

Страница 3: ...ed on the drawing for example the left drawing instructs user to detach power plug from an outlet Cautions Cautions for installation Be careful not to expose the product to benzene thinner or hot wate...

Страница 4: ...ving equipment be sure that plug is detached from an outlet and communication cable is disconnected Damage on cables may cause fire Voltage other than prescribed rated voltage is not permitted which c...

Страница 5: ...from the bottom of one camera to the floor In case that the height of Door camera exceeds the range of min 1 250mm 1 550mm it is impossible to control the screen picture with only the lens angle and t...

Страница 6: ...cancels the interlocking with PIR camera if pressed for three seconds Up Button A plays images saved in standby mode used as Forward key KCV 801R KCV D801R only B used as Right button in setting OSD m...

Страница 7: ...Sub audio phone KDP 602G extension port 13 A B C D Bottom View Rear View Name of Each Part 7 8 9 10 12 13 KCV D801 KCV 801R 4W unload 18W inload available DC 15V 1 2A AC 100 240V KCV 801 AC 100 240V...

Страница 8: ...connected to the door release terminal on the monitor TIV 0 65 2wire UTP 4P 2wire Non polarity DC Main monitor CAM1 KC C60 KC MC30 31 CAM2 VCC GND Audio Video Door Non polarity KDP 602G Extension 4pin...

Страница 9: ...you can use monitor power to CCTV camera B In case the power consumption of CCTV camera is over 200mA DC 12V and distance between CCTV camera and monitor is over 50M the addional power supply shoud b...

Страница 10: ...2 cable connection beween monitors as shown the diagram you can connect up to 50m TIV 0 65mm2 cable x 2EA or CAT5 cable x 2EA Upto 100m TIV 0 8 cable Upto 150m TIV 0 8 cable RG 59 U RG 59 U coaxial c...

Страница 11: ...ion call button If you cancel the internal call during connection LED of the other extended monitor flickers for two minutes 2 Communication with door camera To receive a call from door camera pick up...

Страница 12: ...ocking with PIR Sensor Infrared Motion Detector Camera PIR Sensor Camera At the request of a user PIR sensor camera can be connected to camera port 2 If a user presses button for three seconds a setti...

Страница 13: ...ensor Carmera mode is set PIR Sensor camera detects motions Refer to the image memorizing function KCV 801R KCV D801R only 10 1 Interlocking with PIR Sensor Infrared Motion Detector camera If a user m...

Страница 14: ...ollowing cases will be subject to charge even during warranty period a Breakdown during transport or through careless treatment by consumer b Breakdown cause by unauthorized repair or system modificat...

Отзывы: