![Koch PxtRX Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/koch/pxtrx/pxtrx_operating-manual_1982717056.webp)
Operating manual PxtRX active energy management device
V1.1DE/EN
16
5 Commissioning
En
glish
5
C
OMMISSIONING
Danger to life due to incorrect area application!
The use of the PxtRX active energy management device in
IT networks is prohibited!
IT (Isolated Terra) = floating supply
Danger of burns from hot surfaces!
The housing may heat up to 80° C in operation.
When working on the components, allow sufficient cooling time or wear heat-
resistant protective gloves.
Risk of damage!
Disconnection of the storage units from the PxtRX during
operation is prohibited!
Unauthorised disconnection can also be caused by an incorrect
fuse sizes.
Risk of damage!
During commissioning, ensure that the connected storage is
compatible with the maximum storage voltage (U
C
) specified
in the type description.
The storage voltage (U
C
) must at all times be lower than the
voltage in the DC circuit (DC link) (U
Z
).