10. Maintenance 

As long as the medium to be measured is not contaminated, the device SWK is 
almost maintenance-free. With lime or such depositions within inner sections 
the device should be cleaned regularly.  
 

Attention! Before the commencement of maintenance work, make sure 
that the supply wires are de-energized. 

 
 

 

11. Technical Information 

Housing/Float:  

SWK-x1..: brass nickel plated, Ms 58 

 

SWK-x2..: stainless steel, 1.4301 

 SWK-13..: 

PVC 

Connections:  

G 1/2 female 

Float: 

SWK-x1..: brass, Ms 58 

 

SWK-x2..: stainless steel, 1.4301 

 SWK-13..: 

PVC 

Magnets: ceramic 
Compression spring: 

stainless steel 1.4310 

Gaskets: none 
Butt rings: 

SWK-x1...: brass, Ms 58 

 

SWK-x2...: stainless steel, 1.4301 

 SWK-x13...: 

PVC 

Max. temperature:  

SWK-x1.., SWK-x2: 100 °C 

 

SWK-13..: 60 °C 

Max. pressure:  

SWK-x1.., SWK-x2: 250 bar 

 

SWK-13..: 6 bar 

Loss of pressure: 

200 mbar at full scale 

 

Flow monitors 

 

Flow meters 

and monitors 

 

Pressure loss 

at f.s. 

[mbar] 

Material 

brass 

Material 

stainless 

steel 

Material 

PVC 

Material 

Brass 

Material 

stainless 

steel 

SWK 1101 

SWK 1201 

SWK 2101 

SWK 2201 

160 

SWK 1102 

SWK 1202 

SWK 2102 

SWK 2202 

180 

SWK 1108 

SWK 1208 

SWK 1308 

SWK 2108 

SWK 2208 

180 

SWK 1118 

SWK 1218 

SWK 1318 

SWK 2118 

SWK 2218 

460 

SWK 1140 

SWK 1240 

SWK 1340 

SWK 2140 

SWK 2240 

330 

SWK 1190 

SWK 1290 

SWK 1390 

SWK 2190 

SWK 2290 

360 

SWK 1116 

SWK 1216 

SWK 1316 

SWK 2116 

SWK 2216 

600 

SWK 1124 

SWK 1224 

SWK 1324 

SWK 2124 

SWK 2224 

490 

 
 
 
 

Содержание SWK 1101

Страница 1: ...Operating Instructions for Float Flow Meter Monitor Model SWK...

Страница 2: ...onnection 6 8 Electrical Connection 6 9 Operation Configuration Adjustments 7 9 1 Adjustment of Limit Value SWK 1 7 9 2 Adjustment of Limit Value SWK 2 7 10 Maintenance 8 11 Technical Information 8 12...

Страница 3: ...hen the machines fulfil the EC machine guidelines as per PED 2014 68 EU In acc with Article 4 Paragraph 3 Sound Engineering Practice of the PED 2014 68 EU no CE mark Diagram 8 Pipe Group 1 dangerous f...

Страница 4: ...C cable Brass version Attached reed contact N O with 2m PVC cable PVC VA version Attached and aligned pointer display option 5 Operating Principle KOBOLD Flow Meter Monitor of type SWK operates accord...

Страница 5: ...IIA IIB and IIC b In the Zone 22 Dust Ex Category 3D at non conductive dusts with a minimum igniting energy of 3 mJ c In the Zone 1 Gas Ex Cat 2G into explosion group of IIA IIB and IIC d In the Zone...

Страница 6: ...If possible it should be checked after the mechanical installation whether the connection joints piping is properly sealed Attention A displacement of switching range occurs if the flow takes place f...

Страница 7: ...line and let the flow medium enter slowly till the pointer display shows the desired flow value at which the rising flow should operate the switch the value for the decreasing flow lies below due to t...

Страница 8: ...ainless steel 1 4310 Gaskets none Butt rings SWK x1 brass Ms 58 SWK x2 stainless steel 1 4301 SWK x13 PVC Max temperature SWK x1 SWK x2 100 C SWK 13 60 C Max pressure SWK x1 SWK x2 250 bar SWK 13 6 ba...

Страница 9: ...ax load 5 107 switching operations at low load 10V 1mA 108 switching operations 12 Order Codes Example SWK 1101 Switching range L min water Connection female Flow monitors Flow meters and monitors Swi...

Страница 10: ...SWK page 10 SWK K06 0618 13 Dimensions...

Страница 11: ...aration relates is in conformity with the standards noted below EN 61010 1 2011 Safety requirements for electrical equipment for measurement control and laboratory use EN 60529 2014 Protection through...

Отзывы: