Kobold SEN-86 Series Скачать руководство пользователя страница 10

SEN-86../87.. 

page 10 

 

SEN-86../87.. K04/0618 

Sensor 

(Example: 

SEN-8700 C315

1) 

Seawater resistant 

2)

 Please specify in writing 

3)

 Adapter of PSD usable 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Electrical 

connection 

Class Model 

Output 

Measuring 

range 

Options 

DIN-plug; 

 IP 65 

0.5 

SEN-8700.. 

without

 =  

4 – 20 mA 

 
 

  /2

 = 0 –10 V 

C305 

= -0.6...0 bar 

C315

= -1 ...0 bar 

C505

 = -1...0.6 bar 

C515

 = -1…1.5 bar 

C525

 = -1…3 bar 

C535

 = -1…5 bar 

C545

 = -1…9 bar 

C555

 = -1...15 bar 

B015 

= 0…0.6 bar 

B025

=  0...1 bar 

B035

=  0…1.6 bar 

B045

=  0…2.5 bar 

B055

=  0…4 bar 

B065

=  0…6 bar 

B075

=  0…10 bar 

B085

=  0...16 bar 

A095

=  0...25 bar 

A105

=  0...40 bar 

A115

=  0...60 bar 

A125

=  0...100 bar 

A135

=  0...160 bar 

A140

 = 0...200 bar 

A145

=  0...250 bar 

A155

=  0...400 bar 

A165 

= 0...600 bar 

A170

 = 0...700 bar 

A175

 = 0...800 bar 

H 315

= -30...0 Hg 

P 020

 = 0...10 psi g 

P 025

= 0...15 psi g 

P 045

= 0...30 psi g 

P 055

= 0...50 psi g 

P 060 

= 0...60 psi g

 

P 065

= 0...100 psi g 

P 075

= 0...150 psi g 

P 085

= 0...200 psi g 

P 090 

= 0...300 psi g

 

P 095

= 0...350 psi g 

P 100 

= 0...500 psi g

 

P 105

= 0...600 psi g 

P 115

= 0...1000 psi g 

P 125

= 0...1450 psi g 

P 130

 = 0...2000 psi g 

P 135

= 0...2300 psi g 

P 140

 = 0...300 psi g 

P 145

= 0...3600 psi g 

P 150

 = 0...500 psi g 

P 155

= 0…5800 psi g 

P 160

 = 0…7500 psi g 

P 165

 = 0…10000 psi g 

YYY

= special range,  

          please specify in 
           writing 

Thread 
without

 = G ¼ male 

= absolute  

      pressure for  
      ranges  
     1.0…25 bar 

Y

 = oil- and free of  

      grease for  
      oxygen 

Y

 = silicone- and 

      LABS-free 

Y

 = connection with 

      50 mm cooling  
      fins t

max

 125 °C 

Y

 = connection and  

       housing SS  
      1.4539

1)

 (seewater 

      resistant) instead  
      of 1.4305 

Y

 = connection and 

       housing SS  
       1.4571 instead 
       of 1.4305 

= O-ring FPM  

      instead of NBR 

Y

 = O-ring PTFE  

     (Kalrez) instead of  
      NBR <100 bar 

Y

 = G ¼ DIN 385-E  

       inclusive seal ring 

Y

 = special

3)

 

      connection

2) 

on  

      request, please  
      specify in writing 

= ½” NPT male 

 

M12-plug; 

 IP 67 

0.5 

SEN-8730.. 

Cable 

connection; IP67 

Standard cable 

1 m (other length 

on request) 

0.5 

SEN-8740... 

Cable 

connection;  

IP 68 

0.5 

SEN-8750.. 

Содержание SEN-86 Series

Страница 1: ...Operating Instructions for Pressure Sensors Heavy Duty Compact Model SEN 86 SEN 87...

Страница 2: ...tion and Putting to Operation 4 7 Electrical Connection 5 8 Maintenance 7 9 Trouble shouting 7 10 Technical Information 8 11 Order Codes 9 12 Dimensions 11 13 EU Declaration of Conformance 12 Manufact...

Страница 3: ...ction Instruments are inspected before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of the delivery packaging In case of damage pl...

Страница 4: ...mically aggressive media and mechanical load Particularly hydraulics systems with their high and fast pressure peaks are thus preferred applications 6 Mechanical Connection and Putting to Operation Th...

Страница 5: ...gnal S negative pole of the output signal Shielding Cable protection enclosure earth The sensor can be supplied with a non stabilised DC source with the given volt age range The minimum supply voltage...

Страница 6: ...UB DC Supply UB DC Supply UB DC Indicator Indicator Indicator Indicator Indicator Indicator 1 2 3 green 0V S green 0V S white S DIN 43650 plug 5 pin plug Binder With free cable brown UB blue UB 0V S...

Страница 7: ...by to high supply voltage or by external voltage Return sensor to us for repair Unchanged signal by Pressure port is clocked Clean the pressure port changing pressure Defective electronic caused by to...

Страница 8: ...in rated conditions Electrical connection Plug DIN 43 650 A Plug M12x1 Cable connection Power supply 15 32 VDC Output signal 4 20 mA 2 wire 0 10 VDC Load UB 15 V 0 02 A for 4 20 mA Response time 1 ms...

Страница 9: ...psi g P 090 0 300 psi g P 095 0 350 psi g P 100 0 500 psi g P 105 0 600 psi g P 115 0 1000 psi g P 125 0 1450 psi g P 130 0 2000 psi g P 135 0 2300 psi g P 140 0 300 psi g P 145 0 3600 psi g P 150 0 5...

Страница 10: ...P 075 0 150 psi g P 085 0 200 psi g P 090 0 300 psi g P 095 0 350 psi g P 100 0 500 psi g P 105 0 600 psi g P 115 0 1000 psi g P 125 0 1450 psi g P 130 0 2000 psi g P 135 0 2300 psi g P 140 0 300 psi...

Страница 11: ...SEN 86 87 SEN 86 87 K04 0618 page 11 12 Dimensions in mm SEN 86 SEN 87...

Страница 12: ...2 3 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 2 3 Particular requirements Test configuration operational conditions and performance criteria for trans...

Отзывы: