Installation:
For mounting in a horizontal pipe line you need a vertical G 1" (1" NPT) socket.
Sealing of the connection threads should be carried out with Teflon tape or
similar. The paddle must be able to swing in the inner pipe and should not hit
against the inside wall of the sleeve. Therefore we recommend a max. length
of the socket of 20 mm.
Please take care that the broad dimension of the paddle has to show against
the flow direction. The arrow must show into the flow direction.
To reduce the influence of dirt we recommend to mount the instrument on the
top side of the pipe. This prevents a deposit of dirt. If a mounting on the top is
not possible, we recommend to check and to clean the instrument in regular
intervals (see maintenance).
If possible, check right after the mechanical installation that the connection
thread to the pipe is fully sealed.