1. Contents 

 

1.

 

Contents ........................................................................................................ 2

 

2.

 

Note .............................................................................................................. 3

 

3.

 

Regulation Use .............................................................................................. 3

 

4.

 

Operating Principle ........................................................................................ 3

 

5.

 

Instrument Inspection .................................................................................... 4

 

6.

 

Mechanical Connection ................................................................................. 4

 

7.

 

Electrical Connection .................................................................................... 6

 

8.

 

Technical Information .................................................................................... 8

 

9.

 

Order Codes ................................................................................................. 8

 

10.

 

Maintenance ................................................................................................. 8

 

11.

 

Recommended Spare Parts .......................................................................... 9

 

12.

 

Dimensions ................................................................................................... 9

 

13.

 

EU Declaration of Conformance .................................................................. 10

 

 

 
 
 
 
 
 
 
 
 
 

Manufactured and sold by: 

 

Kobold Messring GmbH 

Nordring 22-24 

D-65719 Hofheim 

Tel.: +49(0)6192-2990 

Fax: +49(0)6192-23398 

E-Mail: [email protected] 

Internet: www.kobold.com 

Содержание PPS-1201

Страница 1: ...Operating Instructions for Polysulfone Paddle Monitor Model PPS ...

Страница 2: ...nnection 4 7 Electrical Connection 6 8 Technical Information 8 9 Order Codes 8 10 Maintenance 8 11 Recommended Spare Parts 9 12 Dimensions 9 13 EU Declaration of Conformance 10 Manufactured and sold by Kobold Messring GmbH Nordring 22 24 D 65719 Hofheim Tel 49 0 6192 2990 Fax 49 0 6192 23398 E Mail info de kobold com Internet www kobold com ...

Страница 3: ...inal pipe sizes greater than NW 32 The paddle switch is available with a factory set limit switch N O or N C It is suitable for low viscosity fluids which have no effects on the instrument materials used The flow throughput switching point is determined by the length of the paddle During installation the paddle length may be reduced by cutting to adjust the set point 4 Operating Principle Media fl...

Страница 4: ...arking according the following table the paddle monitor to your nominal pipe size and the determined switching point Shorter paddle as specified in the table higher switching point Longer paddle as specified in the table lower switching point Please note that the paddle length is not allowed to be longer than the nominal pipe size Please ascertain whether the allowable maximum operating pressure a...

Страница 5: ...ength of the socket of 20 mm Please take care that the broad dimension of the paddle has to show against the flow direction The arrow must show into the flow direction To reduce the influence of dirt we recommend to mount the instrument on the top side of the pipe This prevents a deposit of dirt If a mounting on the top is not possible we recommend to check and to clean the instrument in regular i...

Страница 6: ...roud arrangements Make sure that the supply wires are de energised Loosen the screw of the plug cap and remove the cap Connect the connection cable with the power supply cable in accordance with the connection diagram alongside Plug the plug on to the plug socket and tighten the screw After connection of your external equipment at the connection points the instrument is ready for operation 1 2 1 2...

Страница 7: ... opened when the flow increases and the set point value is reached or exceeded The switch backspaces again with falling flow at the minimum value influenced by the switch hysteresis Hysteresis Defined as the difference between the opening and closing flow values of a contact For example the model PPS 1202 in tube with 11 4 ID set at about 36 L min increasing set point will reset at about 18 L min ...

Страница 8: ...y sealed reed contact Max switching capacity 230 VAC DC 2 A 40 W VA N O N C 100 VDC 0 5 A 5 W changeover contact 9 Order Codes Contact operation with rising flow rate Order number G 1 external thread Order number 1 NPT external thread N C contact PPS 1201 PPS 3205 N O contact PPS 1202 PPS 3202 changeover contact PPS 1203 PPS 3203 10 Maintenance In cases where the flow medium is uncontaminated the ...

Страница 9: ...PPS PPS K02 0416 page 9 11 Recommended Spare Parts 1 Replacement paddle made of polysulfone 12 Dimensions ...

Страница 10: ...this declaration relates is in conformity with the standards noted below EN 61010 1 2011 Safety requirements for electrical equipment for measurement control and laboratory use EN 60529 2014 Protection type through case IP code Also the following EC guidelines are fulfilled 2014 35 EU Low Voltage Directive 2011 65 EU RoHS category 9 Hofheim 27 April 2016 H Peters M Wenzel General Manager Proxy Hol...