10. Technical Information 

Installation position: 

vertical 

Installation length: 

100…540 mm 

Measuring length: 

60…500 mm 

Material: 

stainless steel (1.4301/1.4404) / Alu 

Gasket: 

NBR, FPM, EPDM, PTFE 

Process connection: 

G ¼, ¼” NPT (male) union nut  

Scale resolution: 

2 mm on stick foil 

Max. pressure: 

16 bar  

Ambient temperature: 

-25...+70 °C 

Medium temperature: 

0 °C...+100 °C (0° C...+70 °C with switch)  

Density: 

any (no float used) 

Max. viscosity: 

50 mm²/s 

 

Limit contacts 

Type:

 

capacitive sensor (without ATEX) 

Operating Voltage UB: 

10...65 VDC  

Short-circuit protection: 

pulsing Voltage drop UD: 

≤ 1.8 V  

Operating current IL: 

≤ 200 mA  

No-load supply current I0:  ≤ 15 mA 
Output function: 

3-wire, N/O-contact, PNP Connection type: 

Ø 

5.2 mm, LifYY, PVC, 2 m Core cross-section: 

3 x 0.34 mm2 

Fine adjustment: 

via potentiometer 

Switching indication: 

LED, yellow Protection: 

IP67 

 

 

Material combinations  

 

Code 

Tube 

Body 

Connection 

Seal 

NZJ-A 

borosilicate 

glass 

aluminum 

1.4404 

NBR 

NZJ-K 

stainless steel 1.4301

FPM 

NZJ-S 

stainless steel 1.4404

FPM 

 
 
 

 
 
 

Содержание NZJ

Страница 1: ...Operating Instructions for By pass level indicator Model NZJ...

Страница 2: ...echnical Information 7 11 Order Codes 8 12 Dimensions 9 13 EU Declaration of Conformance 10 14 EU Declaration of Conformance contact 11 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH...

Страница 3: ...ersons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents When used in machines the measuring unit should be used...

Страница 4: ...tallation We recommend that the normal design level indicators be fitted on vessels containing pure liquids while the indicators mounted with cleaning stubs a low or low top stub be fitted on containe...

Страница 5: ...witch Set the switching state LED off by adjusting the potentiometer located the end of the switch Slide the switch housing down until the glass tube is full under the switch The LED must be on If not...

Страница 6: ...J is virtually maintenance free If deposits form is on the inner housing or parts periodic cleaning of the unit is recommended Remove the units from the container with a suitable tool Screw the side f...

Страница 7: ...y any no float used Max viscosity 50 mm s Limit contacts Type capacitive sensor without ATEX Operating Voltage UB 10 65 VDC Short circuit protection pulsing Voltage drop UD 1 8 V Operating current IL...

Страница 8: ...5 PTFE G2 G N2 NPT 00 without 1D 1 1x N O 2D 1 2x N O 1S 2 1x N O 2S 2 2x N O 0 without Y customer specification Please specify the 0 and 100 level relative to the bottom and top connection level in...

Страница 9: ...NZJ Model NZJ K03 0522 page 9 12 Dimensions 30 L 20 L 29 77 L 58 max min L 40 NZJ 1 2 1 1 0...

Страница 10: ...h this declaration relates is in conformity with the standards noted below EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restri...

Страница 11: ...NZJ Model NZJ K03 0522 page 11 14 EU Declaration of Conformance contact...

Отзывы: