background image

The two wire connection switches line
voltage to the load device when switch
is activated. The load device is connected
in series with the NWS.

The three wire configuration switches 
24 VDC to the output when the NWS is 
activated

-VE

4

+VE A

2 1

3

DRY-ON
VIOE
LEER

WET-ON
PLEIN
VOLL

AC/DC 24-240 V

LOAD/CHARGE/LAST

Status Indicator

Flashing: 

Switch not activated (open switch)

Steady: 

Switch activated (closed switch)

Logic Selector Switch

for normally open or

normally closed operation

Rev. 10/05/01

A

+VE

-VE

Load

Line

Neut.

24-240 VAC/VDC

1

2

3

4

Color Codes on Mating Connector

White = 1 = A

Blue = 2 = +VE
Black = 3 = Ground
Brown = 4 = -VE

NO = Normally Open Contact
NC = Normally Closed Contact

V-

V+

= Safety Ground

= Power, 110 VAC or 24 VDC

depending on model

A

+VE

-VE

+

-

24 VDC In

Output

1

2

3

4

V+ V-

NO

NC C

Electrical Connections

Fig. 3 Two Wire Connection

Fig. 4 Three Wire Connection

Fig. 5 Wiring for Relay Output ( R01 & R03)

1

2

3

4

+VE

 

A

-VE

Fig. 6 Plug Connector Pinout (option -M12) 24 VDC only