Kobold NMC Series Скачать руководство пользователя страница 13

  

NMC 

DT0305   Page 

13 

14.  Declaration of conformance ATEX 

 

DT0164

 

DECLARACIÓN DE CONFORMIDAD EU

 

EU DECLARATION OF CONFORMITY 

EU-KONFOMITÄTSERKLÄRUNG 

DÉCLARATION DE CONFORMITÉ 

DICHIARAZIONE DI CONFORMITÀ EU

 

 

KOBOLD MESURA SLU 

Avda. Conflent 68, nave 15 08915  Badalona (España)

 

 

 

 

 

Declara, bajo la propia responsabilidad, que el producto

 

Declares under our sole responsibility, that the product 
Erklärt in alleiniger Verantwortung, dass das produkt 
Déclare sous sa seule responsabilité, que le produit 
Dichiara sotto la propia responsabilità, che il prodotto
 
 
NMC…E

 

 

A los cuales se refiere esta declaración, son conformes a las siguiente Directivas Europeas:

 

To which this declaration relates is in conformity with the following European Directives: 
Mit folgenden Richtlinien konform ist:  
À auxquels se réfère cette déclaration, ils sont conformes aux Directives Européennes suivant : 
A ai quali si riferisce questa dichiarazione, sono conformi alle direttive europee seguente:

 

 

EMC2014/30/EU LVD2014/35/EU Atex2014/34/EU RoHS2011/65/EU

 

 

Normas armonizadas y documentos de la normativa aplicados:

 

Applied harmonised standards and normative documents: 
Angewandte harmonisierte Normen und normative Dokumente: 
Normes harmonisées et documents normatifs appliqués 
Norme armonizzate e documenti normativi applicati:

 

 
EN61010-1 :2011 

EN60079-0:2006 (acc. EN60079-0:2013)   

 

EN61000-6-2 :2006  EN60079-26:2007 (acc. EN60079-26:2015) 

 

                                  EN60079-11:2007 (acc. EN60079-11:2013) 
 

Certificado de examen CE de tipo

 

 

    

Marcado

 

EC-type examination certificate

 

Marking

 

 

EG-baumusterprübescheinigung Kennzeichnung 
Attestation d´examen CE de type

 

Inscription 

Certificazione per esame di tipo CE

 

 

Marcatura

 

LOM07ATEX2032X 

  

              

II 2/1 GD    Ex ia IIC T4 Gb/Ga 

Ex ia IIIC T85ºC Db/Da 
-20ºC < Ta < +60ºC

 

 

Fabricado en

:  

KOBOLD MESURA SLU   Avda. Conflent 68, nave 15 08915  BADALONA (Spain

Made in:  

 

Hergestellt in: 
Fabriqué dans: 
Fabbricato in:

 

 
Organismo notificado

 : 

LOM 0163

 

 

Número notificación

 :  

LOM 05ATEX9070

 

Notified organism

                                                                          

Number notification 

Zertifizierungsstelle                                                                   

 

Zertifikatsnummer 

Organization annoncée                                                             

   

Nombre notification 

Organismo informato                                                                     Notifica di numero

 

 
Badalona june 2017                                                                     Gerente   

 

 

                                   

 
 
 

Содержание NMC Series

Страница 1: ...Operating instructions for Capacitive level transmitter Model NMC 2 Wire 4 to 20mA...

Страница 2: ...11 1 Validity 11 11 2 General considerations 11 11 3 Protection against ESD electro static discharges 11 11 4 Chemical resistance 12 12 Installation in classified zone ATEX 12 13 Label Description ATE...

Страница 3: ...n tanks containing liquids 5 Application The probe of the NMC and the wall of the tank forms an electric capacitor The dielectric of this capacitor when the tanks is empty is the air When the liquid r...

Страница 4: ...NMC is installed using a G1 G2 in DS version The probe must be installed avoiding a good contact between the probe and the tank s wall Electronic of the NMC unit should be protected with shelter again...

Страница 5: ...NMC DT0305 Page 5 8 Electrical connection The maximum resistance of the line in serial depends on the power supply These values have to be bear in mind for the good run of the NMC...

Страница 6: ...in the display using the and keys Confirm with OK 5 In this moment the microprocessor makes the operations to choose the best measurement range This operations takes some seconds 6 When this operation...

Страница 7: ...process When the liquid level will be in the minimum point it will indicate 000 0 and when the liquid level will be in the maximum 100 0 13 Automatically the display shows the main menu Pressing ESC...

Страница 8: ...suring mode 7 In this point the NMC is adjusted The number in indicates the height that reaches the level in the probe 0 to 100 The value of the current will depends f the adjustment of the points 3 a...

Страница 9: ...2 Pressing ESC returns to read mode 9 4 Language 1 Pressing any key you enter in the main menu Press to enter in Language 2 Pressing or we can choose the language for the display Language available Sp...

Страница 10: ...sure 30 bar at 20 C 10 bar at 90 C Media DC value r min 1 5 Materials Housing Polycarbonate Connection St steel 1 4305 NMC N NMC T NMC H PVDF NMC S Probe St steel with PTFE coating NMC N NMC T PVDF co...

Страница 11: ...dations regarding installations in explosive zones as well as the instructions of this safety manual must be followed Verify that all data in the label of the instrument fits the installation requirem...

Страница 12: ...d with the housing in zone 21 22 dust and 1 2 for Gas category 2 or NOT CLASSIFIED Process connection is mounted in the border wall between areas of category 2 and 1 Probe can be mounted in ZONE 20 21...

Страница 13: ...e EMC2014 30 EU LVD2014 35 EU Atex2014 34 EU RoHS2011 65 EU Normas armonizadas y documentos de la normativa aplicados Applied harmonised standards and normative documents Angewandte harmonisierte Norm...

Страница 14: ...uropeas To which this declaration relates is in conformity with the following European Directives Mit folgenden Richtlinien konform ist auxquels se r f re cette d claration ils sont conformes aux Dire...

Страница 15: ...NMC DT0305 Page 15 16 ATEX Certified...

Страница 16: ...NMC P ge 16 DT0305...

Страница 17: ...NMC DT0305 Page 17...

Страница 18: ...NMC P ge 18 DT0305...

Страница 19: ...NMC DT0305 Page 19...

Страница 20: ...NMC P ge 20 DT0305 17 Models...

Страница 21: ...s Version Probe length Mechanical connection ATEX Supply NMC N NMC H NMC T 1 up to 1 meter 2 up to 2 meter 3 up to 3 meter 4 up to 4 meter 2G6 G1 st steel 0 without E ATEX 3 10 35 Vdc NMC S 9G9 G2 PVD...

Страница 22: ...NMC P ge 22 DT0305 19 Notes...

Страница 23: ...NMC DT0305 Page 23...

Страница 24: ...KOBOLD MESURA S L U Avda Conflent N 68 Nave 15 08915 Badalona Tel 34 93 460 38 83 Fax 34 93 460 38 76 E Mail info es kobold com www kobold com Technical data Subject to change without prior notice...

Отзывы: