15.  EU Declaration of Conformance 

We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole 
responsibility that the product: 

 
 

Digital Manometer   

model: MAN-xD… 

 
 

to which this declaration relates is in conformity with the standards noted below:  

 
 

EN 50581:2012

 

Technical documentation for the assessment of electrical 

and electronic products with respect to the restriction of hazardous substances 

 

Additional Model: MAN-LD... 

 

EN 61326-1:2013

 

EMC requirements - Electrical equipment for measurement, control and 
laboratory use – Part 1: General requirements 

 

EN 61010-1:2011

 

Safety requirements for electrical measuring, control and laboratory use – Part 1: 
General requirements 

 

Additional Model: MAN-SD... 

 

EN 6100-6-3:2011

 

Electromagnetic compatibility – Part 6-3: general standards – Emission standard 
for residential, commercial and light-industrial environments 

 

EN 61326-1:2013 

EMC  requirements  -  Electrical  equipment  for  measurement,  control  and 
laboratory use – Part 1: General requirements 

 

EN 61010-1:2011 

Safety requirements for electrical measuring, control and laboratory use – Part 1: 
General requirements 

 

Содержание MAN-LD Series

Страница 1: ...Operating Instructions for Digital Manometer Model MAN SD MAN LD...

Страница 2: ...7 8 Function Keys 8 9 Adjustment 9 10 Control Functions 10 10 1 Control function for MAN LD 10 10 2 Control function for MAN SD 12 11 Maintenance 14 11 1 Notice According to the Battery Law 14 12 Tec...

Страница 3: ...uctions can also be sent to you by post in paper form against an applicable postage fee The devices are only to be used maintained and serviced by persons familiar with these operating instructions an...

Страница 4: ...measuring unit MAN LD MAN SD should be used only when the machines fulfil the EEC machine guidelines 5 Operating Principle The pressure to be measured is sensed by a ceramic sensor and displayed by t...

Страница 5: ...sket flat seal or seal ring according to DIN 16258 While threading in the device install on the hexagonal screw AF 24 and not the gauge housing Only use a wrench for mounting If possible after the mec...

Страница 6: ...N LD1 MAN LD2 MAN LD3 Cable colour 1 VS 24 VDC VS 24 VDC VS 24 VDC brown 2 N O contact white 3 GND GND GND blue 4 analogue output 4 20 mA black 5 N O contact grey Plug M12x1 5 core CableK a b e l a d...

Страница 7: ...ace the 9V block battery in the enclosure and close it with the lid Terminate the connection wires on the plug cable as shown in the illustration below Only with option limit contact or analogue outpu...

Страница 8: ...next menu option previous menu option P jump to the function for MAN SD next menu option previous menu option P 1 x press to switch on P 1 x press to switch off P jump to the function Adjustments and...

Страница 9: ...point setting on inside battery cover 2 password factory pre set 5 3 peak value memory 4 relay option with settable hysteresis 5 factory pre set switching point on 50 of measuring range Factory pre s...

Страница 10: ...ey Note With the switch off of the device the peak value memory is reset P 1xP unit switched on LCD display resetting peak value memory 1234 P 1xP unit switched off peak value memory P last setting ex...

Страница 11: ...n password input P password set on 5 factory setting change P access to further menu options relay set point on rising pressure P last switching point setting set sw point on e g 06 50 change P relay...

Страница 12: ...unit switched off peak value memory P last setting example setting register max value register min value peak value memory off select cancel P confirm selection and go to next menu option password in...

Страница 13: ...change P next menu option password password input P set on 5 factory setting access to further menu options change P last switching point setting relay set point on rising pressure P set sw point on e...

Страница 14: ...symbol Cd Hg or Pb of heavy metal for classification as respective contaminant 1 Cd stands for cadmium 2 Hg stands for mercury 3 Pb stands for lead 12 Technical Data Display 4 digit LCD digit height 1...

Страница 15: ...PT outer thread range 1000 bar only G 1 2 or 1 2 NPT stainless steel 1 4571 other connections on request Temperature of the medium 30 85 C Ambient temperature 0 60 C Storage temperature 30 80 C Allowe...

Страница 16: ...h 17300 h Automatic switch off times 2 64 min auto off can only be set ex works 0 inactive recommended for analogue or switching output Peak value memory MIN or MAX values Reset via keypad MAN LD Pow...

Страница 17: ...8 0 1600 bar 0 none Relay output 9 V Batterie MAN SD2S S connector M12x1 K 0 5 m cable Output 0 2 V 9 V Batterie MAN SD3S Standard 24 VDC MAN LD1S S connector M12 x 1 Relay output 24 VDC MAN LD2S Outp...

Страница 18: ...MAN SD LD Seite 18 MAN SD LD K11 0422 14 Dimensions MAN SD MAN LD 51 14 74 G1 4A M12 x 1 24 turnable display 3 5 5 24 AF 89 38 2 30 51 14 74 G1 4A turnable 3 5 5 24 AF M12 x 1 89 38...

Страница 19: ...N 61326 1 2013 EMC requirements Electrical equipment for measurement control and laboratory use Part 1 General requirements EN 61010 1 2011 Safety requirements for electrical measuring control and lab...

Страница 20: ...uidelines are fulfilled 2014 30 EU EMC Directive 2014 68 EU PED Category I Diagram 1 Vessel Gases Group 1 dangerous fluids 2011 65 EU RoHS category 9 2006 66 EC Directive Batteries and Accumulators Ho...

Отзывы: