12. Technical Information
Electronic
Power supply:
24 V
DC
±10%
110
V
DC
± 30 %,
110, 230 V
AC
– 20/+10 %,
Power input:
max. 4,5 (typically 1,2 W)
max. 3,6 W for 24 V
DC
Ambient temperature:
-20 °C ... +60 °C
CIP compatibility:
max. 140 °C non-operating
Max. pressure:
100 bar
Time delay before availability: max. 12 s
Switching range: approx.
4 cm/s to 200 cm/s
Temperature gradient:
unlimited
Response time:
typically 5,6...12 s
upon request: 2 - 5,6 s (KAL-KS...)
Flow rate indication:
trend indication with 8-LED’s
Switch point adjustment:
with potentiometer, optical indication on LED
chain with flashing LED
Output indicator:
LED, red = alarm,
green = flow OK
Switching output:
24 V
DC
version: semiconductor
PNP/NPN
switchable,
max. 400 mA, short-circuit proof
110
V
DC
version:
relay max. 0,2 A /110 V
DC
110
V
AC
, 230 V
AC
version:
relay max. 5 A
N/O function:
actual value
set point value;(standard
setting: green LED is energised)
output switched through
N/C function:
available as option
Protection type:
IP 65
Case material:
polyamide
Sensor
Medium Temperature:
-20 to +80 °C (standard)
0 to +120 °C (high temperature version)
Maximum Pressure:
100 bar
Connection:
G 1/2 (G 1/4, G 3/4, M 12x1,
1/4" NPT, 1/2" NPT, 3/4" NPT)
Wetted Parts:
1.4305 (KAL-K1215)
1.4301 (all units with order code KAL-K*3)
1.4571 (all units with order code KAL-K*4)