9. Order  Codes

10.  Maintence and Instruction for use

The measuring element is maintenance free when the surrounding air is clean.
Agents that are corrosive and contain solvents, depending upon the type and
concentration of the agent, can result in faulty measurements and cause the
measuring element to break down. Direct sunlight should be avoided. Sub-
stances deposited on the sensor are damaging as they eventually form a water-
repellent film (this applies to all humidity sensors with hygroscopic measuring
elements). Such substances are resin aerosols, lacquer aerosols, smoke depos-
its etc. The water-resistant property of the Kobold sensors allows for cleaning
using water. Solvents cannot be used for this purpose. A light-duty detergent is
recommended. Any detergent residue should, however, always be thoroughly
washed out. A special process ensures that Kobold sensors have good long-term
stability. Regeneration is not necessary, but is also not harmful.
The temperature coefficient as well as the self-heating may vary according to the
location and the application (especially with sensors where electronic and meas-
uring system are integrated in one housing).

The guarantee is no longer valid if the interior of the measuring element
has been accessed.

Содержание AFH-G

Страница 1: ...Operating Instruction for Humidity Temperature Measuring Instrument Model AFH G...

Страница 2: ...ulation applying to procedural safety and the prevention of accidents 2 Contents 1 Note 2 2 Contents 2 3 Specific Application 3 4 Operating Principles 3 5 Instrument Inspection 5 6 Mechanical connecti...

Страница 3: ...ise to a measurable change in length The length of the plastic fibres is thus a measure of the relative humidity The swelling effect acting primarily in the longitudinal direction is sensed by an elec...

Страница 4: ...ain their long term stability it is important that the measuring elements undergo a special ageing process details of which cannot be given here 4 3 Reaction of the sensor Due to the law of diffusion...

Страница 5: ...spection These devices are checked before dispatch and sent away in perfect condition Should the damage to a device be visible we recommend a thorough inspection of the delivery packing In case of dam...

Страница 6: ...rectly to the source of the trouble A suit able suppressor has the added advantage that components such as relays mi croswitches etc have a longer service life Further difficulties during installation...

Страница 7: ...AFH G AFH G 07 02 Seite 7 7 Electrical connection 7 1 Passive sensors 7 2 Active sensors...

Страница 8: ...erage temperature coefficient 0 1 RH K at 20 C and 50 RH Allowed air speed 8 m s with gauze protection optional 15 m s Half life at V 2 m s 1 2 min Sensor length 220 mm Sensor material stainless steel...

Страница 9: ...ents Such substances are resin aerosols lacquer aerosols smoke depos its etc The water resistant property of the Kobold sensors allows for cleaning using water Solvents cannot be used for this purpose...

Страница 10: ...ecuring lacquer When the lacquer is removed the screw can be adjusted After calibration the adjuster screw should again be secured Important The air s capacity to absorb water is influenced among othe...

Страница 11: ...AFH G AFH G 07 02 Seite 11 12 Dimensions...

Страница 12: ...sole responsibility that the product Humidity Temperature Measuring Instrument Model AFH G to which this declaration relates is in conformity with the standards noted below DIN EN 60730 2 1 1993 VDE 0...

Отзывы: