- 14 -
PC 70i, 100i Operating Manual
4.0 SET-UP FOR PCM
Conventional operating procedures apply when using the cutting power source, i.e. connect work lead
directly to work piece and cutting torch is used to POWER adaptor. Wide safety margins provided by the coil
design ensure that the cutting power source will withstand short-term overload without adverse effects. The
cutting current range values should be used as a guide only. Current delivered to the arc is dependent on the
cutting arc voltage, and as cutting voltage varies between different classes of electrodes, cutting current at
any one setting would vary according to the type of electrode in use. The operator should use the cutting
current range values as a guide, and then finally adjust the current setting to suit the application.
Figure 5 Set up for PC series
WARNING:
Before connecting the work clamp to the work and inserting the parts in the cutting torch make sure
the Primary power supply is switched off.
CAUTION 2:
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the
Cutting Power Source.