HPU200 Hydraulic Power Units
Kobelt Manufacturing Co. Ltd.
Rev B
MNL-HPU200
14 of 36
When AC drive motors or large DC drive motors are used, the customer should ensure that
their motor protection and starting circuits conform to ABYC recommendations or other
applicable local electrical codes. Ensure that the electrical cable used to supply the motor and
control connections are sized properly to prevent unreasonable voltage drop.
The solenoids use a common connection Terminal 5 and can be activated by a positive or a
negative control signal. The port and starboard manifold coils are connected to Terminals 6
and 7 respectively. The high-speed coil is connected between Terminal 5 and 8. The high-
speed coil uses the same polarity control signal as the port and starboard solenoids.
DO NOT
energize the coil detached from the valves. It may cause
them to heat up beyond normal operating temperatures.
Table 3: HPU200 Wiring Connections
HPU200
Terminal
#
Wire
Name
Wire
Colour
Function
1
N/C
--
No Connection (N/C)
2
N/C
--
No Connection (N/C)
3
N/C
--
No Connection (N/C)
4
N/C
--
No Connection (N/C)
5
COIL COM
Green
Common Positive or Negative signal for solenoids
coil control.
6
COIL PORT
Red
Positive or Negative signal for PORT direction
solenoid coil.
7
COIL STBD
Black
Positive or Negative signal for STBD direction
solenoid coil.
8
COIL SPEED
White
Positive or Negative signal for high speed solenoid
coil.
Figure 5: HPU200 Terminal Block Diagram