HPU200 Hydraulic Power Units
Kobelt Manufacturing Co. Ltd.
Rev B
MNL-HPU200
11 of 36
3
I
NSTALLATION
3.1
M
ECHANICAL
The pump set must be placed on a horizontal bracket with a solid foundation. It should be
close to and below the steering lines for ease of connections and bleeding.
The HPU is equipped with (2) two clearance holes for 3/8
”
bolts and (4) four holes for
5/16”
bolts through the mounting feet. Ensure that the unit is securely fastened to a suitable
foundation.
Figure 3: HPU Mounting Pattern
3.2
H
YDRAULIC
Three hydraulic connections are required to the pump set. Two lines connect the main
steering lines, and the third line to the header tank of interconnect line which compensates
for thermal expansion of the oil and self bleeds air from the system.
Flexible hose with a pressure rating of minimum 1500 psi working pressure is recommended
for the steering line connections. Flexible hose (min. 250 psi pressure rating) is
recommended for the fill/interconnect line. The hose should be minimum 3/8” inner
diameter.