background image

10

3

KOBE

I N D U S T R I A L

AIR TOOLS

TROUBLESHOOTING

SAFETY INSTRUCTIONS 

Continued

Always keep children away from the work area and where tools are stored.

Never let people who are unfamiliar with the tool use it.

AIR PRESSURE

Air under pressure can cause severe injury.

Always check for damaged or loose hoses and fittings. Whipping hoses can cause serious injury. 

Never direct air at yourself or anyone else.

LUBRICANTS

Mineral oils (Hydraulic fluid) used as lubricants are not considered hazardous to health under normal
conditions. First aid measures however should be taken if:

Ingested

- Wash out

Contact with eyes

- Thoroughly flush eyes with clean water for 5 to 10 minutes and seek medical 

advice.

Contact with skin

- Wash area with soap and water. Remove effected clothing and wash. If irritation 

persists, seek medical advice.

Other

- Seek medical advice immediately

Always wear gloves and goggles when dealing with lubricants.

Always extinguish using a foam or dry powder fire extinguisher. Never use water.

Never allow lubricants to contaminate rivers, water ways or drains.

ELECTROCUTION, FIRE OR EXPLOSION

Always be aware of hidden cables and pipes.

Never work near flammable materials or in a combustible atmosphere. 

Never allow sparks to fall on cleaning rags.

Never make contact with electric power sources as this tool is not insulated.

GENERAL OPERATING HAZARDS

Always ensure that all accessories are rated to the “Free” speed of the tool and intact before fitting or 
using.

Always ensure all users are physically able and competent to handle the size, weight and power of the 
tools and have received appropriate training to perform the task.

Always be aware of the tool rundown time. Control the tool as if it were under power.

Always ensure the tool is kept in a good working condition. Do not use the tool if any parts are missing 
or damaged.

Always make sure that the labels on the air tool are kept legible, indicating the model 
number, serial number, rpm and any warnings. If not, reorder and replace (See page 8).

Never disable the safety lever throttle.

Never modify the tool or accessories and only use it for the task for which it has been designed.

Never force or apply excessive pressure, let the tool do the work for you.

SPECIFIC OPERATING HAZARDS

Never operate without the noise baffler in place.

Never use the Belt Sander as a fixed tool.

Never fit an abrasive to the tool that is not designed to be used with it. This may cause serious injury or
death.

Never switch the Belt Sander on whilst it is in contact with the workpiece.

Never touch the workpiece immediately after sanding, as it will be very hot.

WORKPLACE HAZARDS

Always comply with Health & Safety regulations.

Always be aware of excess hose around the work place. Slip/Trip/Fall is a major cause of serious injury
or death. 

Always maintain a balanced body position and secure footing.

Always use a vice or clamping device to hold the work piece firmly in place. 

Never carry the tool with your fingers on the throttle lever.

AIR SUPPLY AND CONNECTION HAZARDS

Always shut off air supply, drain hose of air pressure and disconnect tools from air supply when not in 
use, before changing accessories or when making repairs.

Always install lock pins when universal twist couplings are used. 

Never use quick disconnect couplings at tool. See instructions for suggested air supply.

Never exceed the maximum air pressure of 6.2bar (90psi).

Never carry the tool by the air hose.

KOBE

I N D U S T R I A L

AIR TOOLS

THE ENVIRONMENT

Always dispose of unwanted tools, accessories and packaging materials in an
environmentally friendly manner.

Never allow lubricants to contaminate rivers, water ways or drains.

KOBE

I N D U S T R I A L

AIR TOOLS

ACCESSORIES

KOBE

I N D U S T R I A L

AIR TOOLS

SERVICE & REPAIR

File belts 457mm (18”) long. Pack of 10.

Width

Grade

Order Code

YRK-204 

*13mm

P300

-2770K

*20mm

P80

-2840K

*6mm

P150

-3200K

*10mm

P120

-3280K

*10mm

P150

-3300K

*13mm

P80

-3340K

*13mm

P120

-3380K

*20mm

P60

-3420K

*20mm

P80

-3440K

25mm†

P60

-3520K

25mm†

P80

-3540K

Replacement contact arms.

Width

Order Code

KBE-298 

*6mm

-4010A

*10mm

-4011A

*10mm offset

-4012A

*13mm

-4013A

*20mm

-4014A

Additional contact arm.

Width

Order Code

KBE-280 

25mm

-5650K

Replacement platen pads.
Sold as pairs.

Width

To suit

Order Code

belt width

KBE-298 

8mm

6mm

-5265T

13mm

10mm

-5248A

18mm

13mm

-5244X

20mm

20mm

-5242V

25mm

25mm

-9660M

Servicing should be carried out at
intervals of 1,000 hours use or
every 12 months, whichever is
sooner.

A   c o m p r e h e n s i v e   r e p a i r   a n d
service facility is available through
your local Kobe agent for all your
electric and pneumatic tools.

Surface preparation belt

Aluminium oxide

Those items marked with an asterisk (*) are already
supplied with your Kobe Mini Belt Sander Kit model
MBS025-Xk.

Other factors outside the tool may cause loss of power or erratic action. Reduced compressor output,
excessive drain on the airline, moisture or restrictions in air pipes or the use of hose connections of
improper size or poor conditions may reduce air supply. If outside conditions are in order and the tool still
runs erratically, disconnect the tool from the air hose and take it to your local Kobe agent.

† Requires the additional 25mm contact
arm shown above to be purchased
seperately.

Отзывы: