background image

 

10 

 

4.  For Rear 3-1/4” x 10” vent installation only: 

Remove  attached  6”  exhaust  and  discard. 
(Figure  11)  Keep  13  screws  to  install  vent 
covers. 

Remove  duct  knockout  from  back  of  the  hood 
and  discard. (Figure  13)  Unscrew  3-1/4”  x  10” 
Vent  Cover  from  rear  exhaust  (located  inside 
hood);  keep  screws  to  install  3-1/4”  x  10” 
Exhaust. 

Align Top Vent Cover {E} and 3-1/4” x 10” Vent 
Cover  (removed  from  rear  exhaust)  using  14 
screws  (13  screws  taken  from  6”  exhaust). 
(Figure  13)  Follow  instructions  in  Step  5  to 
attach Hood-Mounting Bracket {P} and two Duct 
Cover Support {O} using 14 screws (13 screws 
taken from 6” exhaust).  (Figure 15) 

Attach  the  3-1/4”  x  10”  Exhaust  {D}  to  rear 
exhaust (located inside hood) using 10 screws 
taken from rear vent cover.  (Figure 14) 

 

Hood Installation 

CAUTION

:  If  moving  the  cooking  range  is 

necessary to install the hood, turn off the power in 
an electric range at the main electrical box. SHUT 
OFF  THE  GAS  BEFORE  MOVING  A  GAS  RANGE.  
And  use  a  protective  covering  to  protect  cooktop 
and/or countertop from damage.
 

 

5.  Secure  Hood-Mounting  Bracket  {P}  and  two  Duct 

Cover Support {O} on top of the hood with eight pre-
attached screws. Use four 3/16” x 3/8” screws {M} 
for Hood-Mounting Bracket {P}.  (Figure 15) 

6.  Using references on Table 2 and measurements on 

page  16-17,  mark  the  leveling  point  of  the  hood.  
Position  mounting  screws  (provided)  on  the  wall, 
leaving 1/8” away from the wall as shown in Figure 
16. 

7.  Align Hood-Mounting Bracket {P} to the two screws 

on  the  wall  and  hook  hood  into  place.    Tighten 
screws to secure hood to the wall. 

 

CAUTION

:  MAKE  SURE  HOOD  IS  SECURE 

BEFORE RELEASING 
 
 
 
 
 
 
 
 
 
 

Figure 13 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 14 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 15 
 
 
 
 
 
 
 
 
 

 

Figure 16 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Mounting Screws 

Содержание Brillia Series

Страница 1: ...KOBE Range Hoods Brillia Series Model No Under Cabinet CHX9130SQB 1 30 CHX9136SQB 1 36 Wall Mount CHX9130SQB WM 1 30 CHX9136SQB WM 1 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUA...

Страница 2: ...T INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shi...

Страница 3: ...E 14 SPECIFICATIONS 15 MEASUREMENTS DIAGRAMS 16 PARTS LIST 18 CIRCUIT DIAGRAM 20 TROUBLE SHOOTING 21 WARRANTY 22 WARRANTY INFORMATION FORM 24 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I...

Страница 4: ...mproper use mistreatment negligence or any other circumstances beyond the control of KOBE authorized agents Any repair carried out without the supervision of KOBE authorized agents will automatically...

Страница 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Страница 6: ...s x 2 I Stainless Steel Spacer x 2 J Wire Cap x 3 K Screw Package for Under Cabinet A B C D E F G H I J K L Adjustable Duct Cover M Screws Package N Duct Cover Mounting Bracket O Duct Cover Support x...

Страница 7: ...o Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVE...

Страница 8: ...SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Conten...

Страница 9: ...ure 2 Using reference on Page 16 to measure and create access opening for electrical wires and exhaust under the cabinet Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS...

Страница 10: ...the front of the cabinet 7 Draw electrical wires through cabinet access opening 8 Use electrical drill to remove the knockout holes on top of the range hood 9 Place screw provided into the exact cente...

Страница 11: ...Filters H and Stainless Steel Spacers I Angle baffle filter toward back of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Sli...

Страница 12: ...or secure installation Using references on Table 2 and measurements on page 16 17 decide the level of the lumber Refer to Figure 10 Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIG...

Страница 13: ...er Figure 14 Hood Installation CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A...

Страница 14: ...house wires and cap with wire connectors 9 Store wires in the wiring box Ductwork Installation 10 Use steel pipe to connect the exhaust on the hood to the ductwork Use duct tape to make all joints se...

Страница 15: ...of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting position Refer to Figure 20 17 For Sta...

Страница 16: ...r cooking and keep fans running while cooking Adjust speed as needed To operate the fan function Press button to choose from speed o Q QuietMode speed o L Low speed o H High speed Press OFF to turn fa...

Страница 17: ...orn spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface...

Страница 18: ...HOOD DIMENSION W x D x H CHX9130SQB 1 and CHX9130SQB WM 1 29 3 4 x 22 x 9 1 16 CHX9136SQB 1 and CHX9136SQB WM 1 35 3 4 x 22 x 9 1 16 OPTIONAL ACCESSORIES W x D x H 1 Two Piece Adjustable Duct Cover I...

Страница 19: ...llimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO CHX9130SQB 1 30 CHX9136SQB 1 36 30 Knockout Holes A 36 Knockout Holes A B FOR WALL MOUNT DU...

Страница 20: ...17 Hood Mounting Bracket Duct Cover Mounting Bracket Duct Cover Support...

Страница 21: ...iver L1 0402 D001 12 Motor B L1 0301 0120 102B 13 Motor A L1 0301 0120 102A 14 Turbine Impeller B L1 0251 0747 B 15 Turbine Impeller A L1 0251 0747 A 16 Plastic Oil Tunnel L1 0502 0102 17 Safety Scree...

Страница 22: ...19 MODEL NO CHX9130SQB 1 and CHX9130SQB WM 1 30 CHX9136SQB 1 and CHX9136SQB WM 1 36...

Страница 23: ...20 CIRCUIT DIAGRAM MODEL NO CHX9130SQB 1 and CHX9130SQB WM 1 30 CHX9136SQB 1 and CHX9136SQB WM 1 36...

Страница 24: ...ture s is defective Replace LED light fixture s The light wiring s is loose Check wire continuity from Control Panel to LED Driver to LED light fixture s The control panel is defective Replace the con...

Страница 25: ...ted States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owner of this product In Hawaii Alaska and Canada this warranty is limited The...

Страница 26: ...ervice you will be responsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request TO REQUEST WARRANTY...

Страница 27: ...1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com...

Страница 28: ...mand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre propr...

Отзывы: