Operating and assembly instructions

AH 590-720

Freely Suspended Insular Hood

All manuals and user guides at all-guides.com

all-guides.com

Содержание AH 590-720

Страница 1: ...Operating and assembly instructions AH 590 720 Freely Suspended Insular Hood All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...1 AH 590 720 6 Assembly instructions Page 13 19 6 1 Technical data Page 13 6 2 Installation Page 14 19 All manuals and user guides at all guides com ...

Страница 3: ... of the appliance at its installation location He must explain the operating principle of the appliance to the user with refe rence to the operating instructions He must explain to the user how the appliance can be isolated from the mains whenever required Connection possibilities It must be possible to isolate all poles of the appliance from the mains by way of the domestic fuse or by means of ac...

Страница 4: ...hen installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appli ances 24 600 mm and for gas appliances 30 762 mm The extractor hood was conceived for the exhaust air mode The exhaust air can be routed into a se parate exhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue o...

Страница 5: ...densate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be accessible after installation The duct units listed below are available depen ding on the height of the ceiling Stainless steel design ventilation duct LK 590 010 for ceiling heights of 7 10 8 8 2 39 2 64 m LK 590 020 for ceiling heights of 8 8 9 6 2 64 2 89 m LK 590 030 for ceiling height...

Страница 6: ...d of all hotplates and oven must not exceed 13 5 kW Should the nominal heat loads of all hotplates com bined exceed 13 5 kW e g combination with WOK burner during operation only a combination of hot plates of max 13 5 kW must be used Exception the nominal heat loads of all hotplates combined to a maximum of 15 4 kW can be operated for a very short period of time max 15 minutes if the hood is runni...

Страница 7: ...ide as the control panel Fig 20 Ventilation ducts LK 590 020 030 021 031 only the enclosed extension module should be mounted on top of the support frame Follow the above instructions for mounting the support frame and hood 135 8 346 77 8 200 Fig 19 Fig 20 Note the extractor hood is to be installed to a kitchen ceiling or suspended ceiling Ensure that the ceiling is capable of providing a firm hol...

Страница 8: ...lation ducts only LK 590 010 020 030 pull the protective film off the metal surface 8 Place both ventilation ducts over the support frame Take care not to scratch the sensitive duct surface 9 Attach the electrical plug to the support frame with sticky tape so that it can be easily reached later 10 Hang the hood and the support frame with the two key holes to the two screws in the ceiling Fig 22 At...

Страница 9: ...ig 24 Note avoid scratches when pulling the ele ments apart by placing the assembly template for example over the top edge of the bottom duct to protect it 15 Replace the glass plates with the printed side facing down Position the glass plates at the chimney side first Note when putting the glass plates in place make sure that you do not scratch the chimney 16 Check the appliance functions correct...

Страница 10: ...INGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau com us GAGGENAU HAUSGERÄTE GMBH P O BOX 10 02 50 D 80076 MÜNCHEN GERMANY Y 0 89 45 90 01 FAX 0 89 45 90 23 47 All manuals and user guides at all guides com ...