KOBE Brillia RAX21 SQB-2 Series Скачать руководство пользователя страница 4

 

IMPORTANT SAFETY INSTRUCTIONS 

 

- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - 

 

 

WARNING:

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, 

OBSERVE THE FOLLOWING:

 

 

1.  Installation and electrical wiring must be done by qualified professionals and in accordance with 

all applicable codes and standards, including fire-rated construction. 

2.  When  cutting  or  drilling  into  wall  or  ceiling,  be  careful  not  to  damage  electrical  wiring  or  other 

hidden utilities. 

3.  Ducted fans must be vented to the outside. 

a.  Before  servicing  or  cleaning  unit,  open  the  light  panel  and  SWITCH  POWER  OFF  AT 

SERVICE PANEL. 

b.  Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air 

properly, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, 
crawl spaces or garages. 
 

NOTE 

This  warrant  is  void  without  an 

authorized  agent’s  receipt  or  if  unit  is 

damaged  due  to  misuse,  poor  installation,  improper  use,  mistreatment, 
negligence  or  any  other  circumstances  beyond  the  control  of  KOBE 
authorized agents. Any repair carried out without the supervision of KOBE 
authorized agents automatically void the warranty. 

 

 

 

 

KOBE will not be held responsible for any damages to personal property 
or real estate or any bodily injuries whether caused directly or indirectly 
by the range hood. 

 
 

 

WARNING:

  

TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE 

TOP GREASE FIRE:

 

 

1.  Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease 

should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container. 

2.  Always turn hood ON when cooking. 
3.  Use high setting on cooking range ONLY when necessary. 
4.  Do not leave cooking range unattended when cooking. 
5.  Always use cookware and utensils appropriate for the type and amount of food prepared. 
6.  Use this unit only in the manner intended by the manufacturer. 
7.  Before servicing, switch power off at service panel and lock service panel (if possible) to prevent 

power from switching on accidentally. 

8.  Clean ventilating fan frequently. 

 

 

Содержание Brillia RAX21 SQB-2 Series

Страница 1: ...a Series RAX21 SQB 2 Series Under Cabinet Model No RAX2130SQB 2 30 RAX2136SQB 2 36 RAX2142SQB 2 42 Wall Mount Model No RAX2130SQB WM 2 30 RAX2136SQB WM 2 36 RAX2142SQB WM 2 42 INSTALLATION INSTRUCTION...

Страница 2: ...PROBLEMS 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIALS 2 Have your invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement d...

Страница 3: ...RUCTIONS 10 MAINTENANCE 11 SPECIFICATIONS 12 MEASUREMENTS DIAGRAMS 13 PARTS LIST 14 CIRCUIT DIAGRAM 16 TROUBLE SHOOTING 17 WARRANTY 18 WARRANTY INFORMATION FORM 20 READ ALL INSTRUCTIONS CAREFULLY BEFO...

Страница 4: ...n improper use mistreatment negligence or any other circumstances beyond the control of KOBE authorized agents Any repair carried out without the supervision of KOBE authorized agents automatically vo...

Страница 5: ...as If you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce t...

Страница 6: ...KOBE Range Hood B Warranty Registration Card C Quick Reference Guide D 6 Round Exhaust with Rubber Plate x 1 E Baffle Filter x 2 for 30 x 3 for 36 and 42 F Flapper x 2 G Screws A B C D E F G FOR MORE...

Страница 7: ...Card C Quick Reference Guide D 6 Round Exhaust with Rubber Plate x 1 E Baffle Filter x 2 for 30 x 3 for 36 and 42 F Flapper x 2 G Duct Cover H Duct Cover Mounting Bracket I Screws A B C D E F G H I FO...

Страница 8: ...WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height o...

Страница 9: ...6 and the maximum clearance is 30 9 It is important to install the hood at the recommended clearance Installing too low could result in damage and or fire hazard while installing too high may result i...

Страница 10: ...from the hood if any 20 Before using make sure that any accessories such as baffle filters are properly installed where applicable 21 Test the range hood to see if it is working properly THIS RANGE HO...

Страница 11: ...nce for this model is 26 and the maximum clearance is 30 9 It is important to install the hood at the recommended clearance Installing too low could result in damage and or fire hazard while installin...

Страница 12: ...If hardware is desired cut off the plug and connect three wires black white and green to the outlet wires and cap with wire connectors Connect the wires according to color ex black to black Finish 22...

Страница 13: ...ny preparation or cooking and keep fans running while cooking Adjust speed as needed To operate the fan function Press button to choose from speed o Q QuietMode speed o L Low speed o H High speed Pres...

Страница 14: ...cumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5 DO NOT allow salt solutions disinfectants bleaches or...

Страница 15: ...2 29 3 4 x 20 x 23 5 8 42 1 2 RAX2136SQB WM 2 35 3 4 x 20 x 23 5 8 42 1 2 RAX2142SQB WM 2 41 3 4 x 20 x 23 5 8 42 1 2 OPTIONAL ACCESSORIES W x D x H 1 30 Stainless Steel Back Panel Model SSP30 30 x 32...

Страница 16: ...nverted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO RAX2130SQB 2 30 RAX2136SQB 2 36 RAX2142SQB 2 42 FOR WALL MOUNT MODEL NO RAX2...

Страница 17: ...2136SQB 2 36 RAX2142SQB 2 42 No Description Model No Part No 01 6 Round Exhaust Adapter 02 028 02 Hood Mounting Bracket 02 029 03 Capacitor 02 004 04 LED Light 02 005 05 Control Switch 02 006 06 Blowe...

Страница 18: ...Description Model No Part No 01 Duct Cover Mounting Bracket 02 027 02 Duct Cover RAX21DC 2 03 6 Round Exhaust Adapter 02 028 04 Hood Mounting Bracket 02 029 05 Capacitor 02 004 06 LED Light 02 005 07...

Страница 19: ...16 CIRCUIT DIAGRAM MODEL NO RAX2130SQB 2 RAX2130SQB WM 2 30 RAX2136SQB 2 RAX2136SQB WM 2 36 RAX2142SQB 2 RAX2142SQB WM 2 42...

Страница 20: ...tive Replace LED light fixture s The light wiring s is loose Check wire continuity from Control Panel to LED Driver to LED light fixture s The control panel or LED light driver is defective Replace th...

Страница 21: ...ee of charge that failed due to manufacturing defects Consumable parts such as light bulbs filters fuses and oil cups are not covered by this warranty WHAT IS COVERED This warranty is valid in the Uni...

Страница 22: ...to negligence misuse abuse or accident If we determine that the warranty exclusions listed above applies or if you fail to provide all necessary documentation for warranty service you will be respons...

Страница 23: ...el No _______________________________ 3 Serial No _______________________________ For warranty service or spare parts purchase in US contact KOBE Service Center Email best customer service koberangeho...

Страница 24: ...mand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre propr...

Отзывы: