33
Instructions manual |
www.grupotemper.com
KPA 02
Digital clamp meter
Resistance test
Warning
Electric shock hazard.
When measuring circuit impedance, determine that the power supply is
disconnected and the capacitor in the circuit is completely discharged.
• Insert black probe to the COM jack and insert red probe to the INPUT jack.
• Place measuring range switch in
position.
• The meter is in the measurement state.
• Connect the probe to the both ends of resistor or circuit to be tested for
measurement.
• LCD will show readings.
Note
:
1. When the input end is open, LCD shows “0L”out-of-range condition.
2.
When the resistance to be tested > 1MΩ, the meter reading will stabilize
after a few seconds, which is normal for high resistance readings
Diode test
• Insert black probe to the
COM
jack and insert red probe to the
INPUT
jack.
• Place measuring switch in position
.
• Press the
FUNC
key to switch to
measuring state.
• Connect the red probe to diode anode and connect the black probe to
diode cathode to make test.
• LCD will show readings.
Note
:
1. What the meter shows is an approximation of diode forward voltage drop.
2. If the probe has reverse connection or the probe is open, the LCD will
show “0L”
Circuit continuity test
Warning
Electric shock hazard.
When measuring circuit continuity, determine that the power supply is
disconnected and the capacitor in the circuit is completely discharged.
Содержание KPA 02
Страница 1: ...KPA 02 Pinza amperimétrica digital Digital clamp meter www grupotemper com ...
Страница 36: ...36 Instructions manual www grupotemper com KPA 02 Digital clamp meter ...
Страница 37: ...37 Instructions manual www grupotemper com KPA 02 Digital clamp meter ...
Страница 38: ...38 Instructions manual www grupotemper com KPA 02 Digital clamp meter ...