KP 2102
Digital clamp meter
Measuring Frequency by V
range:
WARNING
Beware of Electrocution.
Pay special attention to avoid
electric shock when measuring
high voltage.
Do not input the voltage which
more than 750V rms AC.
Plug the black test lead into the
COM
jack and the red test lead into
the
INPUT
jack.
Set the rotary selector to the
V∽
range position.
Press the “
Hz/%
” to switch to
frequency measurement.
Connect test leads to the two ends of
the source or load for measurement.
Take the reading on the LCD.
NOTE:
1. Frequency test range is 10Hz
-10kHz. It is possible to test the
frequency which is higher than
10kHz but the tolerance of the
test result can not be ensure.
2. “
”
means the maximum input
voltage is 750V rms AC.
Measuring Frequency by
HZ/DUTY range::
WARNING
Beware of Electrocution.
Pay special attention to avoid
electric shock when measuring
high voltage.
Do not input the voltage which
more than 250V rms AC.
Plug the black test lead into the
COM
jack and the red test lead into
the
INPUT
jack.
Set the rotary selector to the
HZ/DUTY
range position.
Connect test leads to the two ends of
the source or load for measurement.
Take the reading on the LCD.
Ω
AC/DC CLAMP METER
AUTO-POWER OFF
Press 2 Sec
MS2108A
COM
INPUT
B.L
HOLD
Hz
/
%
REL
MIN
MAX
SEL
OFF
Hz/DUTY
600 CA T lll
MAX 400A
750V
CAT.
III
MAX
1000V
600V
V
V
40A
400A
Ω
AC/DC CLAMP METER
AUTO-POWER OFF
Press 2 Sec
MS2108A
COM
INPUT
B.L
HOLD
Hz
/
%
REL
MIN
MAX
SEL
OFF
Hz/DUTY
600 CA T lll
MAX 400A
750V
CAT.
III
MAX
1000V
600V
V
V
40A
400A
C orrec t
Inc orrec t