29
Instructions manual |
www.grupotemper.com
KP 2102
Digital clamp meter
LCD (Liquid-crystal
display)
40
30
20
10
0
MkΩ
Hz
mVA
nμF
%
MAX MIN
REL
AC
Alternating current
Direct current
Diode test
Continuity buzzer
Auto range mode
The minimum value is being measured.
The mimum value is being measured.
AUT O
MAX
MIN
DC
REL
H
%
mV, V
A
Ω , k Ω ,
MΩ
H z , k H z
nF, μF
Aotu power off
Battery low
This indicates that the display data is
being held.
Percent (Duty cycle)
Milli-volts, Volts (Voltage)
Amperes (Current)
Nanofarad, Microfarad
Ohms, Kilo-ohms, Mega-ohms
(Resistance)
Hertz, Kilo-hertz (Frequency), Milohertz
DCA zero and relative measure
Specifications
Calibration is required once a year,
to be carried out at a temperature
between 18°C and 28°C (64F° to
82F°) and relative humidity below
75%.
General Specifications
• Auto range. Over range
protection is provided for all
ranges.
• Maximum voltage between
terminals and earth ground:
1000V DC or 750 rms AC
• Operating altitude: max. 2000
meters (7000 ft.)
• Display: 4000 counts with analog
bar LCD display
• Maximum value display: 4000
digits
• Polarity indication: automatic;
‘
-
’
for negative polarity.
• Over range indication:
‘
0L
’
or
‘
-0L
’
• Converter Rate: 3 times/sec; Bar
graph: 30 times/sec.
• Unit indication: function and
unit.
• Auto power off time: 15 minute.
• Operating power : 1.5V×3 AAA
batteries
• Battery low indication:
‘
’
on
LCD
• Temperature factor:
<0.1×Accuracy /°C