
22
Instructions manual |
www.grupotemper.com
KMD 05
Digital multimeter
Warning
To prevent injury or damage to the meter, turn off power to circuit and
discharge all capacitors fully before making continuity mesurements.
Diode test
• Turn off power power to the circuit. Allow all capacitors to discharge.
• Set the rotary switch to the multifuction position. Press
FUNC
once to enter
diode mode.
• Connect the red test lead to the input jack and the black lead to the COM
jack.
• Connect the red test lead to the anode (+) and the black lead to the
cathode (-) of the diode and red the measurement on the display. The
meter will display OL if the connection is reversed.
Warning
To prevent injury or damage to the meter, turn off power to circuit and
discharge all capacitors fully before making diode mesurements.
Battery test
• Set the rotary switch to the appropriate battery test range.
• Connect the red test lead to the input jack and the black lead to the COM
jack.
• Connect the red test lead to the positive (+) end and the black test lead
to the negative (-) end of the battery and read the measurement on the
display
Warning
To prevent injury or damage to the meter, do not connect the meter to a
battery with a voltage rating exceeding 60V AC or 30V DC.
Temperature measurement
• Set the rotary switch to the temperature position.
Press
FUNC
to switch between Celsius and Farenheit.
• Connect the positive end of the K-type thermocouple to the input jack and
the negative end to the COM jack.
Содержание KMD 05
Страница 1: ...KMD 05 Multímetro digital Digital multimeter www grupotemper com ...
Страница 28: ...28 Instructions manual www grupotemper com KMD 05 Digital multimeter ...
Страница 29: ...29 Instructions manual www grupotemper com KMD 05 Digital multimeter ...
Страница 30: ...30 Instructions manual www grupotemper com KMD 05 Digital multimeter ...