18
Factory default, discover IP
There is a reset button on the side of Logic Machine 2. You can either reboot the device by
pressing this button or reset the configuration to factory defaults:
•
Press and hold for <10 sec
– reboot the device
•
Press and hold for >10 sec
– reset networking with IP to factory default
•
Press and hold for >10 sec and again press and hold for >10 sec
– full reset of configuration
to factory defaults
There is also another possibility to discover IP address – LM3 has built-in zeroconf utility by
default, so using the following applications you can find out the IP:
•
Windows PC –
ServiceBrowser
•
Linux PC –
Avahi
•
Android –
ZeroConf Browser
•
iOS –
Discovery
For more info please see here:
http://openrb.com/discover-ip-of-logic-machine-or-streaming-
player/
Standards supported
Logic Machine is compatible with the following standards:
•
KNX/EIB TP, KNXnet/IP
•
Modbus TCP, Modbus RTU
•
BACnet IP, BACnet MS/TP (in development)
•
GSM (Huawei E173 and similar modem support through USB) for sending SMS
notifications and controlling the installation by receiving SMS commands.
•
EnOcean (built-in bi-directional transceiver)
•
DMX (in the box, through RS485)
•
DALI (support is done over RS485 by using external RS485-DALI interface)
•
Ekey biometrical access systems (RS485)
•
HVAC systems can be controller through RS232 interface by using scripting
•
SMTP/Email, SSL
•
SIP (works as PBX for controlling calls, in development)
•
XML (export object values, alerts or errors)
•
RSS (read Error or Alert tab content)
•
JSON, XMPP
•
..
Содержание LogicMachine3 Re:actor
Страница 10: ...10 Terminal connection schemes KNX TP...
Страница 12: ...12 24V power supply...
Страница 13: ...13 Analog inputs e g reed contact...
Страница 14: ...14 Analog inputs 0 10V...
Страница 15: ...15 Digital output...
Страница 16: ...16 Resistive sensor input...
Страница 17: ...17 Analog output...
Страница 26: ...26 Make sure that bus status is Online press button in ETS...
Страница 35: ...35 o Then minimize side bar by pressing on left arrow icon to make the map more visible...
Страница 83: ...83 66 if err then 67 alert FTP upload failed s err 68 end...
Страница 107: ...107...
Страница 108: ...108 1 14 Help Documentation for scripting syntaxes is displayed in Help tab...
Страница 122: ...122 4 16 Running processes System running processes can be seen in Status Running processes window...
Страница 126: ...126 Datapoints can be shown also in a way of table which can be later exported as CSV file...
Страница 141: ...141...