background image

Chirp 3260

Hardware Installation Manual

D101-04965

Revision 3

February 2015

Knudsen Engineering Limited

10 Industrial Road

Perth, Ontario, Canada

Содержание Chirp 3260

Страница 1: ...Chirp 3260 Hardware Installation Manual D101 04965 Revision 3 February 2015 Knudsen Engineering Limited 10 Industrial Road Perth Ontario Canada ...

Страница 2: ... DKG 3 Feb 2015 Overall updates Darren Gibson The information contained in this document is proprietary data of Knudsen Engineering Limited Any disclosure use or reproduction of this information for other than the specified purpose intended is expressly prohibited unless agreed to in writing by Knudsen Engineering Limited D101 04965 Rev3 Page 2 of 9 ...

Страница 3: ... 1 Transducer 2 4 2 4 2 Channel 2 Transducer 2 4 2 4 3 AC Input 2 4 2 4 4 Int Ext Rx Switch 2 5 2 4 5 Ext Rx Input 2 5 2 4 6 Analog Output 2 5 2 4 7 Sync In Out 2 5 2 4 8 USB Interface 2 5 The information contained in this document is proprietary data of Knudsen Engineering Limited Any disclosure use or reproduction of this information for other than the specified purpose intended is expressly pro...

Страница 4: ...ted Knudsen Systems Inc 10 Industrial Road 1 Bridge Plaza Suite 104A Perth Ontario Canada Ogdensburg NY K7H 3P2 13669 613 267 1165 315 393 8861 sales knudseneng com judith knudsensystems com 1 3 Warranty Statement All Knudsen Engineering Limited equipment is guaranteed under warranty against defects in materials or workmanship for one year from date of purchase under normal operation Products that...

Страница 5: ...g rails or support rails be used as part of the installation Final fastening points of the Front Panel are shown in the drawing below CHIRP 3260 Front Panel Mounting Dimensions The information contained in this document is proprietary data of Knudsen Engineering Limited Any disclosure use or reproduction of this information for other than the specified purpose intended is expressly prohibited unle...

Страница 6: ...that a minimum 1U gap be left directly above the Chirp 3260 The image below shows the locations of the system cooling fans and air intake slots CHIRP 3260 Top Panel Dimensions showing Fan locations The information contained in this document is proprietary data of Knudsen Engineering Limited Any disclosure use or reproduction of this information for other than the specified purpose intended is expr...

Страница 7: ... Logging Same as the peripherals any connection to an external data logger is done through the PC There is also the capability to run the data logging package on the same host PC that your EchoControl software is operating on The information contained in this document is proprietary data of Knudsen Engineering Limited Any disclosure use or reproduction of this information for other than the specif...

Страница 8: ...l 2 Transducer The Channel 2 Transducer is the same as the Channel 1 Transducer connection with the exception that it is offset to eliminate the risk of connecting to improper transducer Part Number MS3470L12 3SY Mating Connector MS3476L12 3PY or equivalent Preferred Cable Transducer Dependent A HIGH B SHIELD C LOW 2 4 3 AC Input The Chirp 3260 needs to be powered from an AC source The voltage ran...

Страница 9: ...System Menu of the EchoControl Client you will find an option to change the Sync Mode from Internal to External Once set to External the system will look for a high to low to high transition with a low cycle hold time of at least 1ms but less than 50ms min ping rate on the Sync In BNC located on the system connector panel The echosounder transmit will occur on the rising edge on the sync signal Wi...