background image

CHIRP 3200 SERIES

USER MANUAL

D101-05530

Revision 1

Knudsen Engineering Limited

10 Industrial Road

Perth, Ontario, Canada

K7H 3P2

Phone: 613-267-1165

Fax: 613-267-7085

www.knudsenengineering.com

[email protected]

Содержание Chirp 3200 Series

Страница 1: ...0 SERIES USER MANUAL D101 05530 Revision 1 Knudsen Engineering Limited 10 Industrial Road Perth Ontario Canada K7H 3P2 Phone 613 267 1165 Fax 613 267 7085 www knudsenengineering com info knudsenengine...

Страница 2: ...utput 6 3 3 3 Sync In Out 6 3 3 4 Transmit TX Output 6 3 3 5 USB Interface 6 3 4 System Connection 7 3 4 1 Peripherals 7 3 4 2 Data Logging 7 3 5 Transducer Installation 7 3 5 1 Over the Side 7 3 5 2...

Страница 3: ...local representative or Technical Support Knudsen Engineering Limited 10 Industrial Road Perth Ontario K7H 3P2 Voice 613 267 1165 8 30 am to 5 00 pm E S T Core Hours Fax 613 267 7085 E Mail support kn...

Страница 4: ...channels capable of up to 2kW of output power and two capable of up to 1kW of output power 2 2 Physical Characteristics The Chirp 3200 Series Echosounder is housed in a standard 3U rack case A summary...

Страница 5: ...hirp 3200 is a black box echosounder that utilizes a PC to allow the user to control all system parameters manage peripherals record entire echogram data as well as internal and external data logging...

Страница 6: ...face is useful for oscilloscope viewing of the output signal The expected signal levels are between 0 5 volts 3 3 3 Sync In Out The Sync In allows the output transmit of the Chirp 3200 to be synced to...

Страница 7: ...o the end of a pole that is fastened to the side of the boat The majority of the transducers that are sold by Knudsen Engineering Limited have the option to be purchased with a mounting adapter The ad...

Страница 8: ...the transducer transmits and receives either through the hull itself or through an acoustic window The sea chest will need to be filled with water and may need a stand pipe to provide proper pressure...

Страница 9: ...approximately 25 of the configured total output power The Gain can be selected manually or automatically recommended Shorter pulse lengths are to be used in shallow waters and longer pulse lengths in...

Страница 10: ...confirm operation It may be that the LED has failed If problem continues contact Knudsen Engineering Limited 5 2 No Output to Transducer Confirm that the proper transducer has been connected to the e...

Страница 11: ...Line Pin N Neutral Pin G Ground Transmit Output Pin A Out Pin B Shield Pin C Out Mating Cable End Manufacturer AMPHENOL Part Number MS3476W12 3P USB Pin 1 Power Pin 2 Data Pin 3 Data Pin 4 Shield L N...