Specifications
Hardware
Weight
Approximately eighteen (18) pounds
Exterior Dimensions
9 ¼” Height X 12” Width X 9” Depth
Interior Dimensions
7 ½ Height X 10 ½” Width X 6 ½ Depth
Versions
Surface mount
Recessed version (one-inch flange around the box perimeter)
4-Pin Din Connector
USB port, which collects Audit Trail history information. It also
downloads new configuration information into the box, such as PIN
codes
.
RP-SMA Connector
Connect a WiFi antenna for wireless network if equipped.
RJ-45 Dongle
Connect a Cat5 Ethernet cable for wired networking if equipped.
Override Manual Key
If the electronics fail or the vehicle loses power, the unit can ONLY be
opened using the manual override key. For security purposes, the
manual override key is shipped separate from the unit. If you do not
receive your manual override key, contact Knox immediately.
Electronics
Temperature Range
-40º C to +80 º C (-40 º F to 176V F)
Power Supply
Input Range
10 to 15 volts DC @ 3 amps
Current Drain
(Standby)
120 milliamps
Current Drain
(Door Release)
Up to 3 amps
Current Drain
(Door Open)
150 milliamps
Initial Power
Stabilization Time
5 seconds
Absolute Max Input
20 volts DC