background image

Warnings, Cautions and Others

Mises en garde, precautions et indications diverses

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.

The exclamation point, within an equilateral triangle, is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the appliance.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,  DO

NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION
To reduce the risk of electrical shocks, fire, etc.:

1. Do not remove screws, covers or cabinet.
2. Do not expose this appliance to rain or moisture.

ATTENTION
Afin d’éviter tout risque d’électrocution, d’incendie, etc.:

1. Ne pas enlever es vis ni es panneaux et ne pas ouvrir le coff ret de

l’appareil.

2. Ne pas exposer l’appareil a la pluie ni a l’humidité.

Caution — STANDBY/ON switch!

   Disconnect the mains plug to shut the power off completely. The STANDBY/ON
switch in any position does not disconnect the mains line. The power cannot be
remote controlled.

Attention — Commutateur STANDBY/ON!
    Déconnecter la fiche de secteur pour couper complètement le courant. Le
commutateur STANDBY/ON ne coupe jamais complètement la ligne de secteur,
quelle que soit sa position. Le courant ne peut être télécommandé.

CAUTION

  For U.S.A.

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
   connected.
Consult the dealer or an experienced radio/TV technician for help.

For Canada/pour le Canada

CAUTION:

TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO

WIDE SLOT, FULLY INSERT.

ATTENTION:  POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA
PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET
POUSSER JUSQUAU FOND.

   For Canada/pour le Canada

THIS DIGITAL APPARATUS DOES NOT EXCEED THE CLASS B LIMITS FOR RADIO
NOISE EMISSIONS FROM DIGITAL APPARATUS AS SET OUT IN THE INTERFERENCE-
CAUSING EQUIPMENT STANDARD ENTITLED “DIGITAL APPARATUS,” ICES-003
OF THE DEPARTMENT OF COMMUNICATIONS.

CETAPPAREIL NUMERIQUE RESPECTE LES LIMITES DE BRUITS RADIOELEC-
TRIQUES APPLICABLES AUX APPAREILS NUMERIQUES DE CLASSE B PRESCRITES
DANS LA NORME SUR LE MATERIEL BROUILLEUR: “APPAREILS NUMERIQUES,”
NMB-003 EDICTEE PAR LE MINISTRE DES COMMUNICATIONS.

CAUTION:
•  Do not block the ventilation openings or holes.

(If the ventilation openings or holes are blocked by a newspaper or cloth, etc., the heat may not be
able to get out.)

•  Do not place any naked flame sources, such as lighted candles, on the apparatus.
•  When discarding batteries, environmental problems must be considered and local rules or laws

governing the disposal of these batteries must be followed strictly.

•  Do not use this apparatus in a bathroom or places with water. Also do not place any containers filled

with water or liquids (such as cosmetics or medicines, flower vases, potted plants, cups, etc.) on top
of this apparatus.

ATTENTION:
•  Ne bloquez pas es orifices ou es trous de ventilation.

(Si es orifices ou es trous de ventilation sont bloqués par un journal un tissu, etc., la chaleur peut ne
pas être évacuée correctement de l’appareil)

•  Ne placez aucune source de flamme nue, telle qu’une bougie, sur l’appareil.
•  Lors de la mise au rebut des piles, veuillez prendre en considération es problèmes de l’environnement

et suivre strictement les règles et les lois locales sur la mise au rebut des piles.

•  N’utilisez pas cet appareil dans une salle de bain ou un autre endroit avec de l’eau.
•  Ne placez aucune récipient contenant de l’ear (tel que des cosmétiques ou des médicaments, un vase de

fleurs, un pot de fleurs, une tasse, uec.) sur cet appareil.

Содержание RS8x8HB

Страница 1: ...stallation unauthorizedrepairormodification improper testing accidental or causes external to the product such as but not limited to excessive heat or humidity power failure or improper installation I...

Страница 2: ...he equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between th...

Страница 3: ...ctivates an automatic lamp test at powerup or when requested on the RS232 port Each time a routing command is received the current routing map can be reported on the RS232 port 1 3 DETAILSPECIFICATION...

Страница 4: ...tor at the right rear as viewed from the back of the panel of the RS8x8HB and plug the power unit into a groundedAC power outlet of the voltage and frequency specified on the power unit There is no po...

Страница 5: ...er up for switch configuration changes to take effect cycle the power input to the RS8x8HB In the verbose mode each time a routing command is sent the current routing map will be reported on the RS232...

Страница 6: ...output and push the front panel button with that input number The row of LEDs will stop flashing and the lamp corresponding to the audio crosspoint will flash slowly while the LED corresponding to th...

Страница 7: ...f commands to the routing switcher that will be held until the final command is received then all the commands are executed at the same time For all but the final command in the set use the form Exy E...

Страница 8: ...the existing crosspoint pattern 3 5 ANSWERBACKMODES The user may choose between two modes of answerback verbose and non verbose Select the mode using position 3 of the programming switch located on t...

Страница 9: ...1 ON OFF ON OFF SWITCH2 ON ON OFF OFF 4 4 SETTINGTHEANSWERBACKMODE The user may choose between two modes of answerback verbose and non verbose Select the mode using position 3 of the programming switc...

Страница 10: ...ill cause the word ERROR to be reported Switches are ON when pushed to the right as viewed from the back of the panel 4 5 DISABLINGTHETIMEDSEQUENCER The Timed Sequencer can be activated accidently fro...

Отзывы: