SAFETY REGULATIONS

WARNING

    • A warning reminding the user that he shall conform to

       regulations of electrical safety applicable to the place

       where the generating sets are used.
    •  A warning on the requirements and the precautions to be

       respected by the user in the case of re-supply by

       generating sets of an installation, depending on existing

       protective measures in this installation and applicable

       regulations.

There is the warning label on the machine to remind you

of the safety regulations.  

 

Read the safety instructions

before using the generator. 

Gases such as carbon

monoxide (colorless and

odorless gas) are

produced during operation

which may lead to

suffocation. Only use the

generator in well-ventilated

areas. 

Only fill the generator in well-ventilated a reas

and keep it away from open flames, sparks

and cigarettes. Spilled fuel should be

soaked up immediately. 

Switch off the engine and let it cool

down before filling the generator. Fuel

is easily flammable and may even

explode under certain circumstances. 

GLOSSARIES

Following symbols are quoted on the machine or in this

manual. Please understand their meaning, which will make

your operation easier and safer. 

Glossaries  

 

Symbol

Name

Meaning

V
A

Hz

W

RPM

PF

G1

Volt

Ampere

Hertz

Watt

Power factor

Electric risk

Revolutions

per minutes

Performance

rate

Read

instructions

Safety

warning

Voltage

Current

Frequency (1Hz=60 r/min)

Power

Engine speed

Load transfer efficiency

Generator output power

performance rate meat 

ISO8528G1

Please read instructions

carefully before use

Can be hurt if not

follow instructions

Indication of electrified body.

Pay attention to safety

Symbol

Name

Meaning

Exhaust from the equipment

contains CO, which is invisible

and in odorous. Excessive

suction of CO may make human 

lose consciousness and lead to 

death in serious situation. 

Toxic gas

Electric shock

Fire

Scalding

No raning

Engine oil

Fuel

This is electric device. You may 

suffer electric shock if you

don’t follow the instructions.

The device is electriferous.

No touching during operation.

Fuel and high temperature

generated during operation may 

cause fire. Operate it cautiously.

Do not use the plug or 

electric device in the rain

or make them get wet.

Symbol of adding the engine

oil and the specification is

specified on Page 6.

Symbol of adding the fuel,

which must be gasoline.

Make the machine realize

safe grounding before use

Some parts of equipment will 

generate high

temperature during operation, 

which will scald skin.

Electriferous,

no touching

Grounding

symbol

Содержание KN GEN-30

Страница 1: ...KN GEN 65 6 500 W KN GEN 80 8 000 W Portable generators Generadores port tiles We invite you to read the user manual before operating your equipment Lo invitamos a leer el manual del usuario antes de...

Страница 2: ...ation or maintenance of the generator the operator should lt is impossible for manufacturers to predict all hazardous circumstances that may occur for this reason warnings in this manual and caution s...

Страница 3: ...cause fire during operation lt is strictly prohibited to add fuel during equipment operation In case of adding fuel keep far away from tire brand no smoking In case of adding fuel do not spill fuel on...

Страница 4: ...ier and safer Glossaries Symbol Name Meaning V A Hz W RPM PF G1 Volt Ampere Hertz Watt Power factor Electric risk Revolutions per minutes Performance rate Read instructions Safety warning Voltage Curr...

Страница 5: ...ng mode Starting mode Displacement Net weight Uncertainty L x W x H mm Capacity of fuel tank Valve clearance inlet outlet 0 6 L 196 cc 389 cc 420 cc 1 1 L 1 1 L Weight only for reference Overall dimen...

Страница 6: ...oving the generator in a short time Battery optional It is for starting up the generator In case of nonuse for three months charge it Oil filler cap Oil drain bolt Foot It is for measurement of engine...

Страница 7: ...able SAE TEMP AMBIENT TEMPERATURE Filling fuel No exceeding this level Open the fuel tank cap and fill gasoline the fuel leveler s position will display gasoline mass in the fuel tank and take care th...

Страница 8: ...t load for 5 seconds and then turn on the choke valve switch WAIT 5 sec Connect to load Access electric equipment and turn the circuit breaker to ON Please note that when several loads are used at the...

Страница 9: ...a rough road drain the fuel from the generator beforehand NOTE To transport the generator hold the holding part shaded areas in the figure 1 Take care not to drop or strike the generator when transpo...

Страница 10: ...specified in the drawing 2 Install the storage battery bracket onto the bracket connection tube 3 Install the storage battery shield onto the bracket connection tube 4 Install the assembled bracket o...

Страница 11: ...Wash Wash Replace Readjust Spark plug Valve clearance Cylinder head Fuel tank and strainer Air cleaner Fuel switch sediment cup Fuel tube 1 2 Every 300 hours 2 Every 2 years 2 Every 2 years 2 1 Maint...

Страница 12: ...e inlet valve and 0 15 mm for the outlet valve 10 000 DC 10 000D DC The clearances are 0 07 mm for the inlet valve and 0 10 mm for the outlet valve Clean the spark plug Recommended spark plug models F...

Страница 13: ...park plug fails The temperature of the engine is too low Turn the switch to the on position The spark plug fails Replace clean oil Drain some oil Replace a socket Add oil The generator can not start N...

Страница 14: ...16A AC output 115V 16A Voltage selector V lamp Circuit brecker 10A Ground terminal Engine S W DC terminal DC 12V DC protector 10A Main winding DC diode DC winding Exciter winding Field winding Genera...

Страница 15: ...C output 110V 32A AC output 110V 32A Circuit brecker 22A V lamp Main winding DC winding DC protector 10A DC diode DC terminal DC 12V Engine S W Engine block Engine block Oil level switch Oil alert Spa...

Страница 16: ...nal Engine S W V lamp DC protector 10A DC diode DC terminal DC 12V Circuit brecker 22A Fuse 5A Main winding DC winding Exciter winding Field winding Generator block Fuel cut winding Fuse 5A A V R Engi...

Страница 17: ...n o mantenimiento del generador el operador debe Es imposible para los fabricantes predecir todas las circunstancias peligrosas que pueden ocurrir por esta raz n las advertencias en este manual y las...

Страница 18: ...antemente prohibido agregar combustible durante la operaci n del equipo En caso de agregar combustible mant ngase alejado de la marca de neum ticos no fume En caso de agregar combustible no derrame co...

Страница 19: ...o Amperio Hercios Vatio Factor de potencia Riesgo el ctrico Revoluciones por minuto Tasa de rendimiento Leer instrucciones Advertencia de seguridad Voltaje Corriente Frecuencia 1Hz 60 r min Energ a Ve...

Страница 20: ...do Modo de inicio Desplazamiento Peso neto Incertidumbre largo x alto x fondo mm Capacidad del tanque de combustible Juego de v lvulas entrada salida 0 6 L 196 cc 389 cc 420 cc 1 1 L 1 1 L Peso solo c...

Страница 21: ...cional Es para mover el generador en poco tiempo Bater a opcional Terminal de puesta a tierra Es para poner en marcha el generador En caso de no uso durante tres meses c rguelo Es para hacer que el ge...

Страница 22: ...la tapa del tanque de combustible y llene gasolina la posici n del nivelador de combustible mostrar la masa de gasolina en el tanque de combustible y tenga cuidado de que la posici n m xima de combus...

Страница 23: ...da el interruptor de la v lvula de estrangulamiento ESPERAR ESPERAR 5 SEG 5 SEG Conectar para cargar Acceda al equipo el ctrico y encienda el disyuntor Tenga en cuenta que cuando se utilizan varias ca...

Страница 24: ...identado drene el combustible del generador de antemano NOTA Para transportar el generador sostenga la pieza de sujeci n reas sombreadas en la figura 1 Tenga cuidado de no dejar caer o golpear el gene...

Страница 25: ...0 1000 1000 5 50 5 50 120 Electrodom sticos Foco ahorradora de energia Olla el ctrica Equipo electrico Potencia nominal W Potencia de arranque W Computadora 400 50 300 100 100 400 Electrodom sticos DV...

Страница 26: ...ndro Tanque de combustible y colador Filtro de aire Taza de sedimentos del interruptor de combustible Tubodecombustible 1 2 Cada 300 horas 2 Cada 2 a os 2 Cada 2 a os 2 1 El mantenimiento debe realiza...

Страница 27: ...para la v lvula de salida 10 000 DC 10 000D DC Las holguras son de 0 07 mm para la v lvula de entrada y de 0 10 mm para la v lvula de salida Limpiar la buj a Modelos de buj as recomendados F7RTC y F7...

Страница 28: ...or es incorrecto La holgura de la v lvula est fuera de los l mites La buj a falla La temperatura del motor es demasiado baja Gire el interruptor a la posici n encendido La buj a falla Reemplace por ac...

Страница 29: ...Selector de voltaje L mpara V Circuito disyuntor 10A Terminal de tierra SW del motor Terminal de CD CD 12V Protector CD 10A Devanado principal Diodo de CD Devanado de CD Devanado excitador Campo airo...

Страница 30: ...110V 32A Disyuntor 22A L mpara V Devanado principal devanado de CC Protector CD 10A Diodo de CD Terminal de CD DC 12V SW del motor Bloque de motor Bloque de motor Interruptor de nivel de aceite Alert...

Страница 31: ...r CD 10A Diodo de CD Terminal de CD CD 12V Disyuntor 22A Fusible 5A Devanado principal Devanado de CC Devanado excitador Campo airoso Bloque generador Bobinado de corte de combustible Fusible 5A A V R...

Страница 32: ...www knova com mx...

Отзывы: