Fault phenomenon
Fault cause
Operation method
No fuel
Fill the oil tank with gasoline
The oil switch is not turned on
Turn the oil switch to ON
Clean the oil cup (refer to page 11)
The oil switch is blocked
No engine oil or the engine oil level is low
Clean or replace the spark plug
(refer to page 11)
Move the choke to the “on”
position during operation
Let the engine run at empty
load for more than 10 min.
Turn the circuit breaker
to the “on” position
The shutdown switch is turned off
The circuit breaker is not connected
The plug is poorly contacted
The choke position is incorrect
Clean the filter element to the air filter
Choose appropriate engine oil type
(refer to page 6)
Clear or replace the spark plug
(refer to page 11)
Adjust the valve clearance
(refer to page 11)
The fuel oil is contaminated
Reduce load to the rated limit
The air filter is dirty
The load is too high
The engine oil is too much
The engine oil type is incorrect
The valve clearance is out of limits
The spark plug fails
The temperature of
the engine is too low
Turn the switch to the “on” position
The spark plug fails
Replace clean oil
Drain some oil
Replace a socket
Add oil
The generator
can not start
No power
output
Vibration while
operation
The generator emits black smoke
The generator emits blue smoke
The power
decreases
Vibration while
operation
Common fault analysis
• The environmental requirements of the generator:
• Suitable temperature: -15º C -40º C.
• Suitable humidity: lower than 95%
• Suitable altitude: under 1,000 meters (it should be used with lower power in districts higher than 1,000 meters).
• The
generator set can only be loaded to the rated power under the specified environment conditions. If the environment
conditions are inconsistent with the above standards, or if the cooling conditions of the engine and generator set are
defective; for example, when running in limited areas, it is necessary to reduce the power. It is also necessary to reduce
the power when the temperature, altitude and relative humidity exceed the standards.
• If there is no problem with the conditions above, please turn to the nearby dealer or after-sales service center
for consultants.