Safety information

2

CAT.II: Local level, appliance, PORTABLE 

EQUIPMENT etc., with smaller transient

overvoltages than CAT. III
CAT III: Distribution level, fixed installation, with

smaller transient overvoltages than CAT. IV.
Use the multimeter only as specified in this

operating manual, otherwise the protection

provided by the multimeter may be impaired.
International electrical symbols used on the

multimeter and in this operating manual are

explained on page 9.

• 

Before using the multimeter inspect the case. Do

   not use the multimeter if it is damaged or the

   case (or part of the case) is removed. Look for

   cracks or missing plastic. Pay attention to the

   insulation around the connectors.

• Inspect

 the test leads for damaged insulation

   or exposed metal. Check the test leads for

   continuity. Replace damaged test leads with

   identical model number or electrical

   specifications before using the multimeter

• When

 using the test leads, keep your fingers

   behind the finger guards.

• Do

 not apply more than the rated voltage, as

   marked on the multimeter, between the

   terminals or between any terminal and grounding.

• When

 the multimeter working at an effective

   voltage over 60V in DC or 30V in AC, special

   care should be taken for there is danger of

   electric shock.

• Use

 the proper terminals, function, and range

   for your measurements.

• The

 rotary switch should be placed in the right

   position and no any changeover of range shall

   be made during measurement is conducted to

   prevent damage of the multimeter.

• Disconnect

 circuit power and discharge all

   high-voltage capacitors before testing current,

   resistance, diodes or continuity.

• Replace

 the battery as soon as the battery

   indicator       appears. With a low battery, the

   multimeter might produce false readings that can

   lead to electric shock and personal injury.

• When

 servicing the multimeter, use only the

   same model number or identical electrical

   specifications replacement parts.

• The

 internal circuit of the multimeter shall not be

   altered at will to avoid damage of the multimeter

   and any accident.

• 

Soft cloth and mild detergent should be used to

   clean the surface of the multimeter when

   servicing. No abrasive and solvent should be

   used to prevent the surface of the multimeter

   from corrosion, damage and accident.

• Turn

 off the multimeter when it is not in use and

   take out the battery when not using for a long

   time.

• Constantly

 check the battery as it may leak when

   it has been using for some time, replace the

   battery as soon as leaking appears. A leaking

   battery will damage the multimeter.

• Do

 not use or stoer the multimeter in an

   environment of high temperature, humidity,

   explosive, inflammable and strong magnetic field.

   The performance of the multimeter may

   deteriorate after dampened.

• The

 multimeter is suitable foe indoor use.

Rules For Safe Operation

Automotive Servicing Safety Guide

          To avoid possible electric shock or personal

injury, and to avoid possible damage to the

multimeter or to the equipment under test, adhere 

to the following rules:

          As some automobiles are installed with safe-

ty air bags, you must pay attention to the

cautions in the automotive servicing manual when 

you are working around the components and

wiring of the air bags, or any carelessness will 

open an air bag, resulting in some personal injury. 

Note that the air bag will also be opened for a few 

minutes after the ignition lock is closed (or even 

when the automotive battery is cut off), which is 

driven by the special energy reserve.

• Wear protective eyeglasses which meet safety

   requirements.

• Operate

 the automobile in a well-ventilated place

   so as to prevent the inhalation of any toxic tail gas.

• Keep

 your own tools and testing instruments far

   from all the heater components of the operating

   engine.

• 

Ensure that the automobile has stopped (automatic

   transmission) or put into neutral gear (manual

   transmission) and be sure that it is equipped with

   brakes and the wheels have been locked.

• Do

 not place any tool on the automotive battery

   which will cause a short circuit of the electrodes

   and in turn lead to any personal injury or damage

   to a tool or battery.

• Smoking

 or striking a light near the automobile

   is prohibited in order to prevent any combustion

   or explosion.

• Do

 not leave the automobile in a test operation.

• Heighten

 your vigilance while working around

   an ignition coil, a shunt box, an ignition lead or a

   spark plug socket because these components

   are provided with high voltages when the

   automobile is operating.

• To

 connect or cut off an electronic component,

   close the ignition lock.

• Pay

 attention to the automotive producer’s

   cautions, notes and servicing procedures.

WARNING

WARNING

Содержание KN 8056

Страница 1: ...KN 8056 Digital automotive multimeter Mult metro digital automotriz...

Страница 2: ...tion than other multimeters In addition to the automotive dwell and tach rotation speed this multimeter can be used to test the AC voltage DC voltage DC current resistance diode and continuity Table o...

Страница 3: ...r from corrosion damage and accident Turn off the multimeter when it is not in use and take out the battery when not using for a long time Constantly check the battery as it may leak when it has been...

Страница 4: ...ge of any terminal crack on any spark plug or breakage at the insulation of the ignition lead 6 Check all the vacuum hoses any right line shrinkage bend crack fracture or damage 7 Check the leads any...

Страница 5: ...multimeter may be damaged or the operator himself may be hurt Use proper terminals function and range for the measurement When the testing leads are connected to the current terminals do not parallel...

Страница 6: ...e open circuit voltage between terminals and ground is greater than 60V DC or 30V AC rms The resistance ranges are 200 0 2 000k 20 00k 200 0k 2 000M and 20 00M To measure resistance connect the multim...

Страница 7: ...s disconnected The buzzer sounds continuously when the resistance value is 30W The circuit is in good condition Note The LCD displays 1 indicating the circuit being tested is open Open circuit voltage...

Страница 8: ...test leads to see whether they are well connected 4 Connect the red and black test lead probes in parallel to the two ends of the fuse when the reading of the multimeter should be displayed H Data Hol...

Страница 9: ...lowing pairs of points respectively 1 2 2 3 4 5 5 6 6 7 7 8 8 9 8 10 4 Read the reading of the tested current directly from the display with the normal current being about 100 mA For the special suppl...

Страница 10: ...black test lead probes Their short circuit resistance should be less than 0 5 If it is more check the test lead to see if it is loose or damaged If it is damaged replace it with a new one 4 Connect t...

Страница 11: ...el tape etc is inserted into a concave magnetic pole of the sensor the display of the meter will be enlarged or overloaded if the metal plate is moved away the display will become smaller which proves...

Страница 12: ...Testing see figure 16 figure 15 Black Red Fuel injector figure 16 Long Fuel Short Fuel Black Ground Red If the sensor has a 1 or 3 lead outlet the ground terminal is its shell If the sensor has a 2 o...

Страница 13: ...nsor In a vacuum state the displayed value is generally between 3 V and 5 V The details shall be based on the parameters furnished by the supplier Frequency Type Sensor In a vacuum state the displayed...

Страница 14: ...Input impedance 10M Frequency RPM 30 This only applies to 4CYL General Specifications Maximum Voltage between any Terminals and grounding Refer to different range input protection voltage Accurate Spe...

Страница 15: ...detergent as dirt or moisture in the terminals can affect readings Turn the Meter off when it is not in use and take out the battery when not using for a long time Do not store the Meter in a place o...

Страница 16: ...ing of a fuse always results from improper operation To replace the multimeter s battery 1 Turn the multimeter power off and remove all connections from the terminals 2 Take the multimeter out from th...

Страница 17: ...riente CD resistencia diodo y continuidad Tabla de contenidos G Prueba de ca da de tensi n 24 H Prueba de tensi n del sistema de carga 24 I Prueba del sistema de encendido 25 1 Prueba de la bobina de...

Страница 18: ...e realice el mantenimiento No deben utilizarse sustancias abrasivas ni solventes para evitar da os accidentes y corrosi n en la superficie del mult metro Apague el mult metro cuando no est en uso y sa...

Страница 19: ...ncendido posibles roturas en las terminales grietas en las buj as o roturas en el aislamiento del cable de encendido 6 Revise todas las mangueras de vac o cualquier l nea recta contracci n curvas grie...

Страница 20: ...por favor no intente medir tensiones superiores a 1000 Vp aunque puedan obtenerse dichas lecturas figura 3 ADVERTENCIA Los rangos de voltaje de CD son 200 0 mV 2 000 V 20 00 V 200 0 V y 1000 V Los ran...

Страница 21: ...de m s de 15 minutos C Prueba de resistencia ver Figura 5 Para evitar da os al mult metro o en los dispositivos sometidos a prueba desconecte la alimentaci n del circuito y descargue todos los capacit...

Страница 22: ...mponente y coloque la punta de prueba negro en el c todo del componente El valor medido se muestra en la pantalla Nota En un circuito un diodo en buen estado debe producir una lectura de ca da de tens...

Страница 23: ...de prueba roja al extremo negativo primario de la bobina de encendido Consulte el manual de mantenimiento del autom vil para conocer la posici n espec fica 3 Conecte la punta de cable de prueba negro...

Страница 24: ...motor est apagado consulte el manual de mantenimiento automotriz Si surge cualquier corriente adicional efect e el mantenimiento necesario F Prueba de carga de la bater a activador de voltaje Cuando a...

Страница 25: ...Pruebe la tensi n entre cualquiera de los siguientes pares de puntos respectivamente 1 y 2 2 y 3 4 y 5 5 y 6 6 y 7 7 y 8 8 y 9 8 y 10 Compare las lecturas de las tensiones probadas con las de la tabl...

Страница 26: ...oco mayor porque la resistencia de una bobina var a con la temperatura Cuanto m s elevada la temperatura mayor ser la resistencia y viceversa 1 Mueva los conectores del sistema de encendido del motor...

Страница 27: ...a los de un sensor Hall y los m todos de prueba de ambos sensores tambi n son similares Su resistencia normal se encuentra generalmente en un rango de entre 150 a 1 k Consulte los rangos de resistenc...

Страница 28: ...iza en el autom vil es un sensor de ox geno de calor que tiene 2 extremos calientes Consulte las posiciones de los extremos calientes en varios tipos de manuales automotrices En este momento conecte l...

Страница 29: ...ierra Pie de vac o Teminal de se al V 2 Conecte los sensores de las puntas de prueba roja y negra respectivamente a la terminal de prueba de se ales y a la terminal conectado a tierra Consulte diverso...

Страница 30: ...ultiplica por 10 Frecuencia R P M 30 Esto s lo se aplica a 4CYL La lectura se convierte en R P M reales s lo despu s que se multiplica por 10 Frecuencia R P M 30 Esto s lo se aplica a 4CYL Valores vis...

Страница 31: ...e sobrecarga 1000 VCD or 750 VCA continuos Observaciones A un rango de 10 A Para medici n continua 10 segundos y el intervalo de tiempo entre 2 mediciones mayores a 15 minutos C Corriente CD D Resiste...

Страница 32: ...l mult metro use NICAMENTE fusibles espec ficos para el procedimiento siguiente Para reemplazar el fusible del mult metro 1 Apague el mult metro y retire todas las conexiones de las terminales 2 Retir...

Страница 33: ...Notes Notas...

Страница 34: ...www knova com mx...

Отзывы: