Knog NERD 12 Скачать руководство пользователя страница 4

4

DATA SETTING PROCESS (Fig 1.1)

1. All user-input data is adjusted for each digit separately. 

The current digit to be set will flash. 

2. Press 

A

 to increase the digit value by 1.

3. Hold  down 

A

  for  2  seconds  to  advance  to  the  next 

digit.

4. Press 

B

 to store the on-screen data and advance to the 

next data setting.

5. Once all data setting is complete, hold down 

B

 for 2 

seconds to exit the data setting mode. This can also be 
done at any point whilst in data setting mode, leaving 
the remaining un-set data with a   reading.

INITIATING THE COMPUTER (ALL CLEAR) (Fig 1.2) 

1. A  battery  is  already  loaded  in  the  main  unit  when 

purchased. Hold down 

A

 and 

B

 simultaneously for 3 

seconds to initiate the computer and clear all data.

 

It is important to initiate the computer before first 

usage to prevent the computer producing errors.

2. The LCD segments will be tested automatically after the 

unit is initiated.

3. Press 

A

 to stop LCD test. You will then see a flashing 

KM/H

UNIT SELECTION (Fig 1.3)

Press 

A

 to toggle between 

KM/H

 or 

M/H

 (Mile/hour). Press 

B

 to confirm the current selection.

CIRCUMFERENCE DATA SETTING (Fig 1.4a)

1. The  display  shows 

  for  the  Bike 

1

  default 

circumference value of 2155mm. Measure the value for 
your wheel by following the steps below. (The Bike 

2

 

default circumference value is 2050mm.)

*

MEASURING WHEEL CIRCUMFERENCE (Fig 1.4b) 

Roll the wheel until the valve stem is at its lowest point 
(closest  to  the  ground)  then  mark  this  first  point  on 
the  ground.  Roll  the  bicycle  forward  until  the  wheel  has 
completed one full revolution and the valve stem returns 
to its lowest point. Mark the second point on the ground. 
Measure the distance between the marks. Enter this value 
to  set  the  wheel  circumference.  It  is  important  that  this 
measurement  is  accurate  to  ensure  correct  data  input  
when riding.

ODOMETER AND TOTAL TRIP TIME DATA SETTING (Fig 
1.5)

1. Designed  for  entering  in  previous  data  of 

ODO

 

1

ODO

 

2

*

T.TIMED TRIP

 

1

 and 

T.TIMED TRIP

 

2

*

 after a 

battery replacement. A new user does not need to set 
this data. Each press of 

B

 advances to the next data 

setting screen.

2. Adjust  the  digits  as  described  in  the  Data  Setting 

Process. 

(Fig 1.1)

MAIN UNIT SETUP 

Fig 1.1

DATA SETTING PROCESS

2 seconds

2 seconds

* = N.E.R.D Wireless 12 Function Cycle Computer only

Содержание NERD 12

Страница 1: ...1 Wireless 9 Function Cycle Computer Wireless 12 Function Cycle Computer English 2 13 deutsch 14 25 espaÑol 26 37 Italiano 38 49 日本語 50 61 ...

Страница 2: ...ISH Anatomy 3 Main Unit Setup 4 Functions 7 Button and Normal Operations 8 Bike Installation 10 Battery Change 12 Care and Maintenance Instructions 12 The Full Specs 13 N E R D Wireless 12 Function Cycle Computer only ...

Страница 3: ...most normal opera tions of the computer Throughout this manual the MODE button is designated by A The SET button is located on the underside of the com puter as indicated above It is accessed by using a pen or other small object to depress it The SET button is used for setup operations only Throughout this manual the SET button is designated by B MODE SET ACTIVATION AREA N E R D Wireless 12 Functi...

Страница 4: ...our Press B to confirm the current selection CIRCUMFERENCE DATA SETTING Fig 1 4a 1 The display shows for the Bike 1 default circumference value of 2155mm Measure the value for your wheel by following the steps below The Bike 2 default circumference value is 2050mm MEASURING WHEEL CIRCUMFERENCE Fig 1 4b Roll the wheel until the valve stem is at its lowest point closest to the ground then mark this ...

Страница 5: ...5 TOTAL RIDE TIME REPEAT STEPS FOR CIRCUMFERENCE 2 REPEAT STEPS FOR TOTAL RIDE TIME 2 REPEAT STEPS FOR ODOMETER 2 MEASURE THIS DISTANCE Fig 1 4b MEASURING WHEEL CIRCUMFERENCE LCD SEGMENTS AUTO TEST 3 seconds 2 seconds 2 seconds 2 seconds 5 N E R D Wireless 12 Function Cycle Computer only ...

Страница 6: ...our format Hold down A for 2 seconds to advance to the time setting screen 3 Adjust the clock data according to the Data Setting Process Fig 1 1 4 Press B to save the modified data and exit the clock setting mode MAIN UNIT SETUP cont Fig 1 6 CLOCK SETTING PROCESS 2 seconds 2 seconds 2 seconds 2 seconds 2 seconds N E R D Wireless 12 Function Cycle Computer only ...

Страница 7: ...s When TIMED TRIP is over 100 hours or TRIP DIST is over 1 000km miles The AVG TIMED TRIP and TRIP DIST will automatically reset to MAX MAXIMUM SPEED 0 0 199 9 km hr or 0 0 120 0 mile hr Displays the highest speed recorded from the last RESET operation RELATIVE SPEED GAUGE A 16 segment gauge displaying the current and average speed as a side by side comparison indexed from the recorded MAX speed A...

Страница 8: ...n standby mode AUTOMATIC START STOP The computer will automatically begin counting data upon riding and stop counting data when riding is stopped In order to automatically begin counting the computer must not be in standby mode TURNING ON OFF THE DISPLAY BACKLIGHT Fig 2 3 1 To turn the backlight on hold A for 6 seconds until the display shows the icon 2 To turn the backlight off repeat step 1 unti...

Страница 9: ...4 Hold B for 2 seconds to store the modified data BIKE 1 or BIKE 2 SELECTION Fig 2 4 1 This computer has two sets of circumference memory to calculate data for two different bikes 2 Hold down B for 3 seconds until it enters the bike selection screen a Press A to toggle between Bike 1 or 2 It displays your wheel circumference C b Hold A for over 2 seconds to store the selection and jump to the norm...

Страница 10: ... will enable a good line of sight down to the transmitter and the main unit with minimal physical obstructions 2 Pull the silicon strap around the bars fit it over the hook and you re done The silicon strap on the main computer is designed to accommodate mounting diameters of 22mm up to 38mm For optimum wireless signal clarity your N E R D should be positioned 5cm 2 inches away from your white bik...

Страница 11: ...is located on the wheel side of the fork to ensure a close proximity to the spoke magnet 3 Ensure the arrow on the silicon housing is pointing upward towards the main unit 4 Pull the silicon strap around the fork and fit it over the hook Chose the most suitable one of the two hooks on the strap depending on your fork diameter 5 Once mounted move the transmitter unit around to ensure the closest mo...

Страница 12: ...ing 3 Remove the sealed end cap and the old battery 4 Replace with a new LR44 cell The positive pole of the battery indicated with a sign should be facing outwards 5 Replace the housing lid making sure it is pressed firmly into the housing 6 Re fit the silicon body over the electronics housing making sure the silicon is not twisted BATTERY CHANGE CARE AND MAINTENANCE INSTRUCTIONS 1 Avoid leaving t...

Страница 13: ...ng temperature 0 C 50 C 32 F 122 F Storage temperature 10 C 60 C 14 F 140 F Main unit battery power 1 CR2032 3V cell The transmitter battery should last approximately one year with an average usage of around 1 5 hours per day Transmitter unit battery power 1 LR44 1 5V cell The transmitter battery should last approximately one year with an average usage of around 1 5 hours per day Dimensions Main u...