![Knightsbridge LEDFR6 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/knightsbridge/ledfr6/ledfr6_installation-and-maintenance-manual_1980380002.webp)
LEDFR6
Icons required; 12V and 24V, IP20
Image LEDFR6 , will need revised controller labels
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following product:
LEDFR6
SAFETY
•
Installation of this product should only be carried out by a qualified electrician or competent person to the
current Building and IEE Wiring Regulations (BS7671)
•
Please isolate mains prior to installation/maintenance
•
Check the total load on the circuit (including when this product is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress of Protection) rating of this product when deciding the location for installation
•
This product is Class III
•
This product is IP20 rated
INSTALLATION
•
Provide power to the point of installation
•
Terminate cables from the secondary side of the LED driver to the (red) – (black)
•
Terminate cables from the RGBW LED Flex to LEDFR6 (black to V+) (red to R) (green to G) (blue to B) (white to W)
•
Ensuring correct polarity is observed, wire as shown in Fig 1
24V LED
Driver
LE
DF
R6
2
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following product:
LEDFR6
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current building regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for
installation
• This product is Class III
• This product is IP20 rated
• Provide power to the required point of
installation
• Terminate cables from the secondary
side of the LED driver to the
(red) – (black), ensuring correct polarity is
observed. Wire as shown in Fig. 1
• When using IP20 LED RGBW flex, terminate
cables to LEDFR6 (black to V+) (red to R)
(green to G) (blue to B) (white to W)
• When using IP68 RGBW LED flex, terminate
cables to LEDFR6 (clear to V+) (green to G)
(red to R) (yellow to W) (blue to B)
Fig. 1
V+
R
W
G
B
POWER
POWER
-
+
-
+
LED
Driver