PROGRAMMING 

You may find it helpful to read through the programming instructions before getting started. This will better familiarize 
you with the operation of the UniTech, and will make the actual programming go much quicker. Be aware of the 
following notes. 

If you wish to return to normal operating mode at any point during programming, hold down the ENTER button for 3 
seconds to exit the programming mode. 

While programming, if no buttons are pressed for approximately 2 minutes, UniTech will automatically return to 
normal operating mode. 

Programming changes can be made while UniTech is operating — changes will take effect immediately. This 
allows you to make minor adjustments “on-the-fly” and fine tune the performance of your system. 

When you’re ready to get started, hold down the ENTER button for about 3 seconds to go into the programming 
mode. Release the button when you see the following display... 

Continue on next page 

If you wish to change the menu language, press SCROLL to advance 
through the available choices until your desired language name is shown on 
the display. Press ENTER to continue. 

SELECT LANGUAGE: 
ENGLISH 

All new systems are shipped from the factory with the pass code set at 0000. 
If the system is new, press ENTER to continue. 

If the pass code has been changed from the default of 0000 (explained later 
in this manual) use 

/

 and SCROLL to type in your code, then press 

ENTER to continue. 

ENTER  PASS  CODE: 

0000  PRESS  ENTER 

Use 

/

 buttons to change the speed of the rinse pump. The pump will 

begin running when either button is pressed. When the desired setting has 
been reached, press ENTER — the pump will stop running, and you will 
advance to the next menu. 

RINSE SPEED: 
   50% 

You will only see this display if UniTech recognizes that a sanitizer “satellite 
pump” is connected. Use 

/

 buttons to change the speed of the sanitizer 

pump. The pump will begin running when either button is pressed. When the 
desired setting has been reached, press ENTER — the pump will stop 
running, and you will advance to the next menu. 

SANITIZ SPEED: 
   50% 

Use the SCROLL button to choose probe or probeless detergent feed mode, 
then press ENTER to continue. 

DETERGENT MODE: 
PROBE_ 

Содержание UniTech Warewash

Страница 1: ...0900591 Rev A 07 04 Page 1 of 24 UniTech Warewash Instruction Manual ...

Страница 2: ...rass 18 Dry Detergent Plastic 19 Wiring Diagrams Single Transformer 20 Dual Transformer 21 European Models 22 Declaration of Conformity 23 Warranty Information 24 Knight Locations 24 CAUTION Wear protective clothing and eyewear when dispensing chemicals or other materials Observe safety handling instructions MSDS of chemical mfrs CAUTION To avoid severe or fatal shock always disconnect main power ...

Страница 3: ...itial Detergent Charge 1 sec 1 64 sec Door Mode 1 128 sec Conveyor Mode Detergent Recharge Time 1 sec 0 255 sec Rack Count 0 0 65536 Recharge after n Racks 1 1 99 Det Feed Limit Off On Off SPECIFICATIONS Pass code does not change when clearing all programmed settings Rack count has its own menu to allow resetting back to zero SAFETY SYMBOL EXPLANATIONS Listed below are explanations of the safety s...

Страница 4: ...l to a two product system then it should be attached to the unit prior to installation see page 14 Before beginning the installation make sure you have the following tools and materials ready INSTALLATION MOUNTING 1 Remove existing dispenser if any 2 Use the mounting bracket to mark where the holes need to be drilled Drill the three holes 3 Press in the dry wall anchors and mount the bracket 4 Han...

Страница 5: ...the dishwasher for a power source that is active during the wash cycle only for example the magnetic contactor that controls the wash pump motor Single transformer Connect leads to the detergent signal source Signal voltage range is 14 240 VAC Dual transformer Connect leads to the detergent power source must be 115 208 or 230 VAC Rinse Signal In addition to running the rinse pump the rinse power s...

Страница 6: ... male piece can freely rotate Clearance is tight in the pump case and you cannot easily rotate the conduit nut Instead hold the conduit nut with a wrench and rotate the male piece to tighten 5 Disconnect the wiring harnesses to gain easier access to the wiring terminal strip The terminal strip panel can be removed by loosening one screw panel is slotted therefore the screw does not need to be remo...

Страница 7: ...ueeze tube and the bulkhead fitting 3 Cut a suitable length of 1 4 OD poly tubing and connect between the suction left side of the detergent pump s squeeze tube and the pickup tube provided Be sure to draw tubing through the end of the pickup tube 4 Hand tighten the compression nuts on both the bulkhead fitting and pickup tube Plastic ties can be used to cinch around the connections where the poly...

Страница 8: ...ime Rinse delay and rinse limit are functional with door machines only Sanitizer Pump A menu selection sets the sanitizer pump to operate with detergent feed or with rinse feed The sanitizer pump will run simultaneously with detergent or rinse whether using probe or probeless mode rinse delay or rinse limit BUTTON FUNCTIONS ENTER Holding the enter button for 3 seconds approx switches between run a...

Страница 9: ...anguage press SCROLL to advance through the available choices until your desired language name is shown on the display Press ENTER to continue SELECT LANGUAGE ENGLISH All new systems are shipped from the factory with the pass code set at 0000 If the system is new press ENTER to continue If the pass code has been changed from the default of 0000 explained later in this manual use and SCROLL to type...

Страница 10: ...ailable timing range is 0 to 255 seconds Use to set the recharge time then press ENTER to continue DET RECHARG TIME 01 SEC This setting allows you to choose how many racks will be counted before triggering the recharge feed The range is 1 to 99 racks Use to set recharge rack count then press ENTER to continue NOTE Ensure that this setting is for 1 rack if using a two transformer unit on a door mac...

Страница 11: ...ss code in the previous menu you will be prompted to confirm your choice If you wish to pick a different number press SCROLL to return to the previous menu otherwise press ENTER to continue ARE YOU SURE 0000_IS NEW CODE Use SCROLL to choose door or conveyor as the type of dishmachine in use then press ENTER to continue MACHINE TYPE DOOR_ If you wish to clear the initial charge counter press the DO...

Страница 12: ...ROLL DOWN TO RESET EVERYTHING Use SCROLL to choose whether you wish to have the sanitizer pump run simultaneously with the rinse pump or the detergent pump then press ENTER to continue SANI RUNS WITH RINSE_PUMP This feature will stop the rinse pump after XX seconds of continuous rinse signal conserving rinse agent on door type dishmachines that fill through the rinse valve Use to choose from 0 to ...

Страница 13: ... 60 80 100 120 Concen Set Point in Knight Units Knight Kit Titration Drops Titration Drops vs Knight Units Poly Titration Drops vs Knight Units UniTech Det Concen ms vs Knight Units 1 0 1 2 3 4 5 6 7 8 9 0 20 40 60 80 100 120 Knight Units Concen ms Concen ms vs Knight Units Linear Concen ms vs Knight Units ...

Страница 14: ...and slowly slide the pump into place 4 Insert the two provided screws and tighten 5 Set the DIP switches back of sani pump so that switch 1 is ON and all other switches are OFF 6 Process complete Now ready for mounting Display Shown on Power Up When the UniTech dispenser is powered up for the first time after adding a sanitizer pump the system will automatically check for new devices and the follo...

Страница 15: ... according to the transformer configuration of your UniTech system diagram to the right shows jumper locations This is particularly important when changing circuit boards so the new board will work correctly 5 Replace with new circuit board and carefully line up the buttons and LED s with the holes on the cover Snap the board into place on the upper and lower mounting tabs Set the jumpers per tabl...

Страница 16: ...Page 16 of 24 0900591 Rev A 07 04 PARTS DIAGRAM ALL CONFIGURATIONS ...

Страница 17: ...0900591 Rev A 07 04 Page 17 of 24 PARTS DIAGRAM LIQUID DETERGENT ...

Страница 18: ...Page 18 of 24 0900591 Rev A 07 04 PARTS DIAGRAM DRY DETERGENT Brass Solenoid Model ...

Страница 19: ...0900591 Rev A 07 04 Page 19 of 24 PARTS DIAGRAM DRY DETERGENT Plastic Solenoid Model ...

Страница 20: ...Page 20 of 24 0900591 Rev A 07 04 WIRING DIAGRAM 1 TRANSFORMER ...

Страница 21: ...0900591 Rev A 07 04 Page 21 of 24 WIRING DIAGRAM 2 TRANSFORMER ...

Страница 22: ...Page 22 of 24 0900591 Rev A 07 04 WIRING DIAGRAM EUROPEAN MODELS ...

Страница 23: ...0900591 Rev A 07 04 Page 23 of 24 ...

Страница 24: ... Return Authorization KRA number freight prepaid and found to be defective upon factory authorized inspection Bearings and pump seals or rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equip...

Отзывы: