background image

Stratos®Pro 

A401B CONDI

User Manual

www.knick.de

Latest Product Information: 

094711

Содержание Stratos Pro A401B CONDI

Страница 1: ...Stratos Pro A401B CONDI User Manual www knick de Latest Product Information 094711 ...

Страница 2: ...ble page numbers and headlines help you to quickly find the information 68 69 Configuration Alarm Settings CONTROL input FLOW MIN FLOW MAX 1 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using keys press enter 4 Select ALARM menu using keys press enter 5 All items of this menu group are indicated by the ALA code Press enter to select menu edit using arrow keys see ne...

Страница 3: ... documentation available on our website www knick de Safety Instructions Quickstart Guides Installation and first steps Operation Menu structure Calibration Error messages and recommended actions Specific Test Report Control Drawings ...

Страница 4: ...ng Plates Terminal Assignments 20 Power Supply Signal Lines 21 Connecting the Sensor 22 Cable Preparation SE 655 SE 656 23 Wiring Example SE 655 SE 656 24 Wiring Example SE 660 25 Wiring Example Yokogawa ISC 40 26 Wiring Example Yokogawa IC 40S 27 Wiring Example SE 670 28 Connecting the SE 670 Sensor 29 Protective Wiring of Relay Contacts 30 User Interface Keypad 32 Display 33 Signal Colors Displa...

Страница 5: ...nput 78 Alarm Settings 80 Limit Function 84 Pulse Length Pulse Frequency Controller 93 Controller 94 WASH Contact 98 Time and Date 100 Tag Number 100 Calibration 103 Selecting a Calibration Mode 103 Calibration with Calibration Solution 104 Product Calibration 106 Calibration by Input of Cell Factor 108 Zero Calibration in Air with Calibration Solution 109 Temp Probe Adjustment 110 Measurement 111...

Страница 6: ...tion Solutions 135 Concentration Measurement 137 Concentration Curves 138 Error Handling 144 Error Messages 145 Sensoface 147 FDA 21 CFR Part 11 149 Electronic Signature Passcodes 149 Audit Trail 149 Index 150 Trademarks 159 Passcodes 160 ...

Страница 7: ...40 60 mm 30 45 mm see page 17 panel mounting 138 mm x 138 mm cutout to DIN 43700 see page 18 Weather protector accessory The weather protector which is available as accessory provides additional protection against direct weather exposure and mechanical damage see page 17 Connection of sensors cable glands For connecting the cables the enclosure provides 3 knockouts for cable glands M20x1 5 2 knock...

Страница 8: ...ger The internal logbook TAN SW A002 can handle up to 100 entries up to 200 with AuditTrail TAN SW A003 see page 117 2 parameter sets A B The device provides two parameter sets which can be switched manu ally or via a control input for different process adaptations or different process conditions For overview of parameter sets table for copy see page 52 Password protection Password protection pass...

Страница 9: ...see page 41 CONTROL floating digital control input The CONTROL input can be used either for parameter set selection A B or for flow monitoring see page 78 The Wash contact can be used for indicating the active parameter set see next page Power supply Current is provided through a universal power supply 24 230 V AC DC AC 45 65 Hz Options Additional functions can be activated by entering a TAN page ...

Страница 10: ...age 84 Wash cleaning function This contact can be used for controlling a rinsing probe or for indicating the active parameter set page 98 Signal outputs The device provides two current outputs for transmission of measured value and temperature for example The output curve is adjustable linear bilinear or logarithmic see page 62 onwards Relay contacts Four floating relay contacts are available 8 10...

Страница 11: ...11 Typical Application of Stratos Pro A401B CONDI ...

Страница 12: ...e connected with other equipment Commissioning must only be performed by trained personnel autho rized by the operating company Whenever it is likely that protection has been impaired the device shall be made inoperative and secured against unintended operation The protection is likely to be impaired if for example the device shows visible damage the device fails to perform the intended measuremen...

Страница 13: ... device in a hazardous location observe the specifications of the Control Drawing download www knick de Before commissioning you must provide proof that the device may be connected with other equipment such as a supply unit includ ing cables and wires In hazardous locations the device shall only be cleaned with a damp cloth to prevent electrostatic charging Devices which have already been used sha...

Страница 14: ...Overview of Stratos Pro A401B CONDI 8 10 9 C D E F G H 5 6 B A Output 1 CONDI input Output 2 7 14 15 16 1 2 3 4 17 18 19 20 21 22 R1 R2 Alarm R3 R4 Wash Power RS 485 11 12 13 HOLD input Control input Current input ...

Страница 15: ...ntation cf p 3 11 10 9 8 7 6 5 4 1 2 3 Fig Assembling the enclosure 1 Jumper 3 x 2 Washer 1 x for conduit mounting Place washer between enclosure and nut 3 Cable tie 3 x 4 Hinge pin 1 x insertable from either side 5 Enclosure screw 4 x 6 Sealing insert 1 x 7 Rubber reducer 1 x 8 Cable gland 3 x 9 Filler plug 3 x 10 Hexagon nut 5 x 11 Sealing plug 2 x for sealing in case of wall mounting ...

Страница 16: ...g plan All dimensions in mm 1 Cable gland 3 x 2 Knockouts for cable gland or conduit 21 5 mm dia 2 knockouts Conduits not included 3 Knockout for pipe mounting 4 x 4 Knockout for wall mounting 2 x 148 148 42 42 42 14 117 41 21 43 1 2 34 80 74 6 2 4 3 ...

Страница 17: ...e mounting accessory ZU 0737 All dimensions in mm Fig Pipe mount kit accessory ZU 0274 All dimensions in mm 147 199 91 185 1 2 3 4 1 Hose clamp with worm gear drive to DIN 3017 2 x 2 Pipe mount plate 1 x 3 For vertical or horizontal posts or pipes 4 Self tapping screw 4 x ø40 ø60 ...

Страница 18: ...ng Fig Panel mount kit accessory ZU 0738 All dimensions in mm 1 Circumferential sealing 1 x 2 Screws 4 x 3 Position of control panel 4 Span piece 4 x 5 Threaded sleeve 4 x Cutout 138 x 138 mm DIN 43700 30 76 31 1 22 1 2 3 4 5 ...

Страница 19: ...t by a system administrator prior to com missioning The electrical installation shall conform to the national regulations for electrical installations and or other applicable national or local codes or regulations The power supply shall be disconnectable from the device by a two pole circuit breaker Switch and circuit breaker shall be located in close proximity to the equipment and be easily acces...

Страница 20: ...G Control drawing 212 002 300 C C US US C C US US 20 T 55 C a Type 4X C US Class II III Zone 22 AEx tD 22 T85 C AEx nA II T4 Ta 55 C Ex nA II T4 Ta 55 C DIP A22 Class II III Div 2 GP E F G Class I II III Div 2 GP A B C D E F G T4 Ta 55 C C US CSA 08 2117513 24 15 to 230 10 V AC 45 to 65 Hz 12 VA Power 24 15 to 80 10 V DC 4 W FM 3037411 3037411 C CSA 08 2117513 APPROVED FM C US C US Made in Germany...

Страница 21: ...wdriver to pull out the terminals Fig Terminals device opened back of front unit Power Supply Signal Lines Connect the power supply for Stratos Pro A401B CONDI to terminals 21 and 22 24 230 V AC 45 65 Hz 24 80 V DC Terminal assignments ...

Страница 22: ...ull out the terminals Connect the sensor lines with the sensor connection terminals module terminals A K Connecting the Sensor Fig Terminals device opened back of front unit Sensor connection MK CONDI module Fig MK CONDI module terminal assignments ...

Страница 23: ...N YE Coax RD Coax WH Insert the special cable through the cable entry into the terminal compartment Remove the already separated part of the cable insulation 1 Turn the shielding mesh 2 over the cable insulation 3 Then shift the crimp ring 4 over the shielding mesh and tighten it using a pince 5 3 4 5 receive hi receive lo send lo send hi RTD temp RTD temp sense temp shield ...

Страница 24: ... hi RTD RTD sense RTD GND shield Wiring Example SE 655 SE 656 Measuring task Conductivity temperature Sensors SE 655 SE 656 sensor Connecting the pre assembled cable Cable Device Yellow Blue Red Red Blue Green White Coax white Coax red Shield Green yellow ...

Страница 25: ...i receive lo send lo send hi RTD RTD sense RTD GND shield Wiring Example SE 660 Measuring task Conductivity temperature Sensor SE 660 sensor Cable Device Yellow Blue Red Red Blue Green White Coax black Coax red Shield Green yellow ...

Страница 26: ...ng Example Yokogawa ISC 40 Measuring task Conductivity temperature Sensor Yokogawa ISC40 Pt 1000 Cable Device Black Black Blue Red Coax WH Coax BN Black Jumper Configuration settings for this sensor Sensor Conductivity temperature SENSOR OTHER RTD TYPE 1000Pt CELL FACTOR 1 88 TRANS RATIO 125 ...

Страница 27: ...ield Wiring Example Yokogawa IC 40S Measuring task Conductivity temperature Sensor Yokogawa IC40S NTC 30k Cable Device Black Black Blue Red Coax WH Coax BN Black Configuration settings for this sensor Sensor Conductivity temperature SENSOR RTD TYPE CELL FACTOR Approx 1 7 TRANS RATIO ...

Страница 28: ...ace of the device for an A2 Series 2 wire device the measuring module slot must be empty Therefore first remove the measuring module from the slot see next page When the SE 670 sensor is selected in the Configuration menu the default values are taken as calibration data They can then be modified by calibration Cable types M12 ferrules 5 m CA M12 005NA 10 m CA M12 010NA 20 m CA M12 020NA ...

Страница 29: ...olor Brown Green Yellow White transparent shield Connecting the SE 670 Sensor NOTICE The slot for the MK CONDI module must be empty be sure to remove the module Areas for placing the screwdriver to pull out the terminals 1 13 14 22 ...

Страница 30: ... of the contacts will be reduced For suppression of sparks and arcing components such as RC combinations nonlinear resistors series resistors and diodes should be used Typical AC applications with inductive load 1 Load 2 RC combination e g RIFA PMR 209 Typical RC combinations for 230 V AC capacitor 0 1 µF 630 V resistor 100 Ω 1 W 3 Contact 1 2 3 1 2 3 ...

Страница 31: ...amps A1 Inductive load A2 Free wheeling diode e g 1N4007 Observe polarity A3 Contact B1 Capacitive load B2 Resistor e g 8 Ω 1 W at 24 V 0 3 A B3 Contact C1 Incandescent lamp max 60 W 230 V 30 W 115 V C3 Contact Make sure that the maximum ratings of the relay contacts are not exceeded even during switching Typical Protective Wiring Measures WARNING ...

Страница 32: ...rectly to measuring mode press 2 s Measuring mode other display Retrieve information Show error messages Configuration Confirm entries next configuration step Calibration Continue program flow Measuring mode Call menu Arrow keys up down Menu Increase decrease a numeral Menu Selection Arrow keys left right Previous next menu group Number entry Move between digits ...

Страница 33: ...e running 13 Info available 14 Hold mode active 15 Main display 16 Secondary display 17 Proceed using enter 18 Not used 19 Diagnostics 20 Configuration mode 21 Calibration mode 22 Measuring mode 23 Sensoface 24 Unit symbols Signal Colors Display Backlighting Red Red blinking Alarm in case of fault display values blink Input error illegal value or wrong passcode Orange HOLD mode Calibration Configu...

Страница 34: ...selection of parameter set A B or flow Measured value and tag number TAG Time and date Output currents Controller upper display controller output Y lower display setpoint Note By pressing the meas key in measuring mode you can view the displays for approx 60 sec You must configure the device for the respective measurement task enter key Active parameter set configuration Display indicates OUT1 e g...

Страница 35: ... arrow key 7 Confirm entry by pressing enter To select the operating mode 1 Hold meas key depressed 2 s directly to measuring mode 2 Press menu key the selection menu appears 3 Select operating mode using left right arrow key 4 Press enter to confirm the selected mode Selection menu Selected mode blinks 1 4 3 2 5 7 6 ...

Страница 36: ... display The MAIN DISPLAY is the display which is shown in measuring mode To call the measuring mode from any other mode hold the meas key depressed for at least 2 sec approx 2 s Press enter to select a display as MAIN DISPLAY the secondary display shows MAIN DISPLAY NO Use the UP DOWN arrow keys to select MAIN DISPLAY YES and confirm by pressing enter The display color changes to white This displ...

Страница 37: ...e as is the magenta screen which indicates asset management messages for predictive diagnostics such as maintenance request pre alarm and sensor wear The alarm status has a particularly noticeable red display color and is also signaled by flashing display values Invalid inputs or false pass codes cause the entire display to blink red so that operating errors are noticeably reduced White Measuring ...

Страница 38: ...a deviation the device can be adjusted In that case the device displays the actual value and internally corrects the measurement error of the sensor During calibration the device is in HOLD mode During calibration the device remains in the HOLD mode until it is stopped by the operator Configuration The analyzer must be configured for the respective measurement task In the Configuration mode you se...

Страница 39: ...ion via TAN Access via code factory setting 5555 Calibration with calibration solution Calibration by input of cell factor Zero calibration Product calibration Adjustment of temperature probe Display of calibration data Display of sensor data Self test RAM ROM EEPROM module Logbook 100 events with date and time Display of direct uncorrected sensor signals Display of software version model designat...

Страница 40: ...ompt ensures that the installation is ready for operation e g sensor reinstalled located in process HOLD active 21 4 HOLD active Output current mA Output signal for HOLD FIX setting 21 0 mA Output signal for HOLD LAST setting Output signal during HOLD Output signal response LAST The output current is frozen at its last value Recommended for short configuration procedures The process should not cha...

Страница 41: ...in the logbook During an alarm the display blinks the display backlighting turns red Error messages can also be signaled by a 22 mA output current see Configuration The alarm contact is activated by alarm and power failure see also Configuration Alarm Settings 2 sec after the failure event is corrected the alarm status will be deleted HOLD inactive 0 2 V AC DC HOLD active 10 30 V AC DC Process con...

Страница 42: ...m Sensocheck Polarization Cable 22 mA Error Messages Flow CONTROL input Alarm contact opens ERR 10 Conductance 3500 mS HOLD HOLD HOLD via menu or input Last Fix CONF Configuration CAL Calibration SERVICE Service Alarm and HOLD Messages ...

Страница 43: ...er set selection or for flow measurement pulse principle depending on its assignment in the Configuration menu When preset to flow measurement an alarm can be generated when the measured flow exceeds a specified range specify value default 5 liters h specify value default 25 liters h Power supply 12 24 V AC DC 13 12 CONTROL input ...

Страница 44: ... enter opens a menu item Use the arrow keys to edit a value Press enter to confirm save the settings Return to measurement Hold meas key depressed 2 s Select menu group Menu group Code Display Select menu item Sensor selection Menu item 1 Menu item Current output 1 Current output 2 Compensation Control input parameter set or flow measurement Alarm mode Relay outputs Cleaning Setting the clock Tag ...

Страница 45: ...set B Sensor selection Current output 1 Current output 1 Current output 2 Current output 2 Compensation Compensation Control input Alarm mode Alarm mode Relay outputs Relay outputs Cleaning Parameter set selection Setting the clock Tag number External switchover of parameter sets A B You can switch between parameter sets A and B by applying a signal to the CONTROL input parameter setting 12 13 Max...

Страница 46: ...ting is a fixed parameter set A Wrong settings change the measurement properties PARSET blinks in the lower line Select parameter set using and keys Select PARSET A PARSET B Press enter to confirm Cancel by pressing meas The active parameter set can be signaled using the WASH contact If configured correspondingly the WASH contact signals Parameter set A open contact Parameter set B closed contact ...

Страница 47: ...0 NTC 1000PT CELL FACTOR XX XXx 01 980 TRANS RATIO XXX Xx 120 0 MEAS MODE Cond Conc Sal Cond Cond MEAS RANGE x xxx mS cm xx xx mS cm xxx x mS cm x xxx S m xx xx S m x xxx mS cm Conc Solution 01 NaCl 02 HCl 03 NaOH 04 H2SO4 05 HNO3 06 H2SO4 07 HCl 08 HNO3 09 H2SO4 10 NaOH 01 NaCl TEMP UNIT C F C CIP COUNT ON OFF OFF SIP COUNT ON OFF OFF ...

Страница 48: ...A END 20 mA CORNER X Input range selected CHANNEL Vertex X BEGIN CORNER X END rising BEGIN CORNER X END falling CORNER Y Input range selected CHANNEL Default 12 mA Vertex Y 0 4 mA CORNER Y 20 mA LOG BEGIN 0 4mA Decades END 20 mA Decades TMP C BEGIN 0 4mA 50 250 C END 20 mA 50 250 C TMP F BEGIN 0 4mA 58 482 F END 20 mA 58 482 F FILTERTIME 0 120 SEC 0000 SEC 22mA FAIL ON OFF OFF HOLD MODE LAST FIX L...

Страница 49: ...led via TAN TEMP EXT I INPUT 0 20 mA 4 20 mA 4 20 mA C BEGIN 4 mA 50 250 C 000 0 C END 20 mA 50 250 C 100 0 C F BEGIN 4 mA 58 482 F END 20 mA 58 482 F Control input CNTR_IN IN CONTROL Parameter set switchover PARSET or flow measurement FLOW PARSET FLOW FLOW ADJUST 12000 pulses liter 000 0 20000 pulses liter Alarm ALARM ALA DELAYTIME 0 600 SEC 0010 SEC SENSOCHECK ON OFF OFF FLOW CNTR ON OFF OFF ON ...

Страница 50: ...CONTACT LEVEL Within meas range HYSTERESIS 0 50 full scale DELAYTIME RL2 CHANNEL FUNCTION CONTACT LEVEL Within meas range HYSTERESIS 0 50 full scale DELAYTIME CTR CHANNEL TYPE PLC PULSE LENGTH PFC PULSE FREQ SETPOINT Within meas range DEAD BAND 0 50 full scale P GAIN I TIME D TIME HOLD MODE Configuration ...

Страница 51: ...put in text line ___ Configuration Choices Default Cleaning contact WASH Selected in text line WASH PARSET A B WASH WASH WASH CYCLE 000 0 999 9 h 000 0 h WASH TIME 0000 9999 SEC 0060 SEC CONTACT N O N C N O Parameter set PARSET Select fixed parameter set A or switch between A B via control input or manually in measuring mode PARSET FIX CNTR INPUT MANUAL fixed parameter set A ...

Страница 52: ...rameter sets are stored in the EEPROM As delivered the two sets are identical but can be edited Note Fill in your configuration data on the following pages or use them as original for copy Configuration Original for Copy ...

Страница 53: ...ermination SNS Temperature unit SNS CIP counter SNS SIP counter OT1 Current range OT1 Process variable OT1 Lin bilin log output OT1 Current start OT1 Current end OT1 Vertex X bilinear curve only OT1 Vertex Y bilinear curve only OT1 Filter time OT1 22 mA error current OT1 HOLD mode OT1 HOLD FIX current These parameters cannot be adjusted in parameter set B the values are the same as in parameter se...

Страница 54: ... OT2 HOLD mode OT2 HOLD FIX current COR TC SELECT COR Temp coefficient COR Reference temperature COR Current range COR Current start COR Current end IN Parameter set A B or flow IN Flow meter Adjusting pulses liter ALA Delay ALA Sensocheck on off ALA Flow control FLOW CNTR on off ALA Minimum flow hysteresis fixed at 5 ALA Maximum flow hysteresis fixed at 5 REL Usage RL1 Process variable RL1 Functi...

Страница 55: ...length CTR Pulse frequency CTR Setpoint CTR Neutral zone CTR P gain CTR I time CTR D time CTR HOLD mode CTR Delay CTR Contact response WSH Contact function WSH Wash cycle WSH Wash duration WSH Contact response CLK Time Date TAG Tag number These parameters cannot be adjusted in parameter set B the values are the same as in parameter set A Configuration Original for Copy ...

Страница 56: ...enu using keys press enter 5 All items of this menu group are indicated by the SNS code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed Sensor type Temperature probe Cell factor Transfer ratio Measuring mode Measuring range Concentration determination Temperature unit Cleaning cycles Ste...

Страница 57: ... using keys Press enter to confirm Enter cell factor using keys Press enter to confirm Enter transfer ratio using keys Press enter to confirm 1000PT 100PT 30 NTC 01 980 XX XXx 120 00 XXX Xx Measuring mode Select desired measuring mode using keys Press enter to confirm Cond Conc Sal Measuring range For cond measurement only Select desired range using keys Press enter to confirm x xxx mS cm xx xx mS...

Страница 58: ...entration determination temperature unit 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using press enter 4 Select SENSOR menu using keys press enter 5 All items of this menu group are indicated by the SNS code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed...

Страница 59: ... For conc measurement only Select desired concentra tion solution using see appendix for ranges Press enter to confirm 01 NaCl 02 HCl 03 NaOH 04 H2SO4 05 HNO3 06 H2SO4 07 HCl 08 HNO3 09 H2SO4 10 NaOH Temperature unit Select C or F using keys Press enter to confirm C F 5 ...

Страница 60: ... ISM only Adjust CIP cleaning cycles SIP sterilization cycles 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using press enter 4 Select SENSOR menu using keys press enter 5 All items of this menu group are indicated by the SNS code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode i...

Страница 61: ...ON OFF Sterilization cycles on off Select ON or OFF using keys Activates deactivates log ging in extended logbook Press enter to confirm ON OFF The cleaning and sterilization cycles are logged to measure the load on the sensor Suitable for biochemical applications process temp approx 0 50 C CIP temp 55 C SIP temp 115 C Note A CIP or SIP cycle is only entered into the logbook 2 hours after the star...

Страница 62: ...tput current range Linear Logarithmic Current start 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using press enter 4 Select OUT1 menu using keys press enter 5 All items of this menu group are indicated by the OT1 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is ...

Страница 63: ...applies to selected process variable range If the adjusted range is exceeded the device automatically switches to the next higher range Autorange Current end Enter value using keys Press enter to confirm Entered value applies to selected process variable range If the adjusted range is exceeded the device automatically switches to the next higher range Autorange Assignment of measured values Curren...

Страница 64: ...ge Output current during HOLD Output current for HOLD FIX 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using press enter 4 Select OUT1 menu using keys press enter 5 All items of this menu group are indicated by the OT1 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicat...

Страница 65: ...cally switches to the next higher range Autorange Bilinear curve Vertex X Y Enter value using keys Press enter to confirm Entered value applies to selected vertex of bilinear curve Corner X process variable and Corner Y output current see figure below Vertex of bilinear curve Output current Process variable 5 Example Current range 4 20 mA Current start 0 µS cm Current end 200 µS cm Vertex CORNER X...

Страница 66: ... value must be specified in the same units either in µS cm or in S m see listing 0 001 mS cm 0 001 S m 0 01 mS cm 0 01 S m 0 1 mS m 0 1 S m 1 0 S m 10 0 S m 100 S m The start value is the next decade value below the lowest measured value The end value is the next decade value above the highest measured value The number of decades results from Number of decades log end value log start value The out...

Страница 67: ... Logarithmic curve biLIN Bilinear curve LIN Linear characteristic Start value Enter value using keys Press enter to confirm Start value of logarithmic output curve End value Enter value using keys Press enter to confirm End value of logarithmic output curve Possible start and end values for the logarithmic curve S cm S m 5 ...

Страница 68: ... Output current during HOLD Output current for HOLD FIX 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using press enter 4 Select OUT1 menu using keys press enter 5 All items of this menu group are indicated by the OT1 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator...

Страница 69: ...s a jump at the input 100 the output level is at 63 after the time interval has been reached The time interval can be set from 0 to 120 sec If the time interval is set to 0 sec the current output directly follows the input Note The filter only acts on the current output not on the display or the limit value During HOLD the filter is not applied This prevents a jump at the output Time interval 0 12...

Страница 70: ...t current during HOLD Output current for HOLD FIX 1 Press menu key 2 Select CONF using keys press enter 3 Select parameter set using press enter 4 Select OUT1 menu using keys press enter 5 All items of this menu group are indicated by the OT1 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is di...

Страница 71: ... the output FIX During HOLD a value to be entered is main tained at the output Select using Press enter to confirm LAST FIX Output current for HOLD FIX Only with FIX selected Enter current which is to flow at the output during HOLD Enter value using keys Press enter to confirm 00 00 21 00 mA HOLD active 21 4 HOLD active Output current mA Output signal for HOLD FIX setting 21 0 mA Output signal for...

Страница 72: ...enu group are indicated by the OT2 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Current range Process variable LIN biLIN LOG output Current start Current end Bilinear Vertex X Bilinear Vertex Y Time averaging filter Output current during error message Output current during HO...

Страница 73: ...0 mA or 0 20 mA range using keys Press enter to confirm 4 20 mA 0 20 mA Process variable Select using keys Cond Conductivity TMP Temperature Press enter to confirm Cond TMP Begin 0 C End 100 C All the following adjustments are made as for current output 1 see there 5 ...

Страница 74: ... press enter 4 Select CORRECTION menu using keys press enter 5 All items of this menu group are indicated by the COR code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Temperature compensation Current input external temp measurement Current start Current end 5 ...

Страница 75: ...perature coefficient nLF Temperature compensa tion for natural waters to EN 27888 NaCl from 0 to 26 by wt 0 120 C Press enter to confirm Temperature compensation process medium Enter reference temperature With linear compensation only Step 1 Enter temperature compensation of the process medium Step 2 Enter reference temperature Enter value using keys Press enter to confirm Permissible range 0 199 ...

Страница 76: ...is menu group are indicated by the COR code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Temperature compensation Current input external temp measurement if enabled via TAN Current start Current end 5 Temperature Compensation Current input for temp measurement ...

Страница 77: ...nt current input enabled TAN Current range Select desired range using keys Press enter to confirm Current start Modify digit using keys select next digit using keys Press enter to confirm Input range Current end Enter value using keys Press enter to confirm Input range 5 ...

Страница 78: ...tems of this menu group are indicated by the IN code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed CONTROL input function PARSET FLOW FLOW ADJUST Configuration CONTROL Input Parameter set selection via external signal or flow measurement ...

Страница 79: ...erated Configuration Menu item Action Choices Select function of CONTROL input Select using keys Press enter to confirm PARSET selecting parameter set A B via signal at CONTROL input Flow for connecting a pulse output flow meter Adjust to flow meter With Flow selected you must adjust the device to the flow meter used Enter value using arrow keys Press enter to confirm 12000 pulses liter Display Fl...

Страница 80: ...u using keys press enter 5 All items of this menu group are indicated by the ALA code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed ALARM Delay Alarm Sensocheck Alarm CONTROL input For flow monitoring Max flow alarm For flow monitoring Min flow alarm ...

Страница 81: ...ed during normal operation N C It opens in the case of alarm or power outage As a result a failure message is provided even in the case of line breakage fail safe behavior For contact ratings see Specifications 17 18 Alarm R3 Error messages can also be signaled by a 22 mA output current see Error messages and Configuration Output 1 Output 2 Operating behavior of the alarm contact see Operating Sta...

Страница 82: ...ARM menu using keys press enter 5 All items of this menu group are indicated by the ALA code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed ALARM Delay Alarm Sensocheck Alarm CONTROL input For flow monitoring Max flow alarm For flow monitoring Min flow alarm ...

Страница 83: ...te an alarm when assigned to FLOW flow monitoring in the CONF menu FLOW CNTR Flow measurement allows monitoring the minimum and maximum flow pulse counter Alarm Minimum flow FLOW MIN Specify value Default 05 00 liters h Alarm Maximum flow FLOW MIN Specify value Default 25 00 liters h 5 ...

Страница 84: ...r 5 All items of this menu group are indicated by the RL1 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Use of relays Select process variable Limit 1 switching characteris tics function Limit 1 contact type Limit 1 setpoint Limit 1 hysteresis Limit 1 delay 5 ...

Страница 85: ...ct desired process variable using keys Press enter to confirm Limit 1 function Select desired function using keys LoLevel active if value falls below HiLevel active if value exceeds setpoint Press enter to confirm Lo LEVL Hi LEVL Limit 1 icon Limit 1 contact response N O normally open contact N C normally closed contact Select using keys Press enter to confirm Limit 1 setpoint Enter setpoint using...

Страница 86: ...enu group are indicated by the RL1 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Use of relays Select process variable Limit 1 switching characteris tics function Limit 1 contact type Limit 1 setpoint Limit 1 hysteresis Limit 1 delay 5 Limit Function Relay 1 ...

Страница 87: ... keys Press enter to confirm 0 50 full scale Limit 1 delay The contact is activated with delay deactivated without delay Adjust delay using keys Press enter to confirm 0 9999 SEC 0010 SEC Limit Lo Hysteresis Setpoint Contact 0 1 Signal Limit Hi Hysteresis Signal Setpoint Contact 0 1 5 ...

Страница 88: ...ss enter 5 All items of this menu group are indicated by the RL2 code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Select process variable Limit 2 switching characteris tics function Limit 2 contact type Limit 2 setpoint Limit 2 hysteresis Limit 2 delay 5 ...

Страница 89: ...rmally closed contact Select using keys Press enter to confirm Limit 2 setpoint LEVEL Enter setpoint using keys Press enter to confirm Within meas range Limit 2 hysteresis HYSTERESIS Select hysteresis using keys Press enter to confirm 0 50 full scale Limit 2 delay DELAYTIME The contact is activated with delay deactivated without delay Adjust delay using keys Press enter to confirm 0 9999 SEC 0010 ...

Страница 90: ...90 ...

Страница 91: ...e g closed tank batch processes PI controller Application for non integrating control systems e g drains PID controller The additional derivative action compensates for measurement peaks Setpoint Controller output Yp 100 100 Deviation Xw mS cm Neutral zone Yp 0 Relay 1 Relay 2 Controller characteristic ...

Страница 92: ...0 Tolerated deviation from desired value With the setting 1 mS cm for example a deviation of 0 5 mS cm from the desired value does not activate the controller 100 50 Xw Controller output Y KC 500 KC 200 KC 100 KC 50 Proportional action Gradient KC Deviation Process variables Cond Conc SAL MR 0 2 MR 0 4 MR 0 6 MR 0 8 Measuring range MR Controller output Y I action D action dYP dt 1 TR P action YP Y...

Страница 93: ...signal relay contact of pulse length controller ON time Y 80 ON time Y 20 Pulse length 1 0 1 0 Pulse frequency controller PFC The pulse frequency controller is used to operate a frequency controlled actuator metering pump It varies the frequency with which the contacts are switched on The maximum pulse frequency pulses min can be defined It depends on the actuator The contact ON time is constant I...

Страница 94: ... keys press enter 5 All items of this menu group are indicated by the CTR code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Use of relays Select process variable Controller type Pulse length Pulse frequency Setpoint Neutral zone Controller P action Controller I action Controller D...

Страница 95: ...irm Cond TMP Controller type Pulse length controller PLC or pulse frequency controller PFC Select using keys Press enter to confirm PLC PFC Pulse length Only with PLC Pulse length Adjust using keys Press enter to confirm 0 0600 SEC 0010 SEC Pulse frequency Only with PFC Pulse frequency Adjust using keys Press enter to confirm pulses per minute Setpoint Adjust setpoint using keys Press enter to con...

Страница 96: ...sing keys press enter 5 All items of this menu group are indicated by the CTR code Press enter to select menu edit using arrow keys see next page Confirm and proceed by pressing enter 6 Exit Press meas key until the meas mode indicator is displayed 6 5 Use of relays Select process variable Controller type Pulse length Pulse frequency Setpoint Neutral zone Controller P action Controller I action Co...

Страница 97: ...eft right arrow keys Controller P action Adjust P action using keys Press enter to confirm 10 9999 0100 Controller I action Adjust I action using keys Press enter to confirm 0 9999 SEC 0000 SEC Controller D action Adjust D action using keys Press enter to confirm 0 9999 SEC 0000 SEC Behavior during HOLD Select response using keys Press enter to confirm Y LAST Y OFF 5 ...

Страница 98: ...eter set A using keys press enter 4 Select WASH menu using keys press enter 5 All items of this menu group are indicated by the WSH code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 End Press meas key until the meas mode indicator is displayed Function Cleaning interval Cleaning duration Contact type 5 6 5 ...

Страница 99: ...rameter set A open contact Parameter set B closed contact Cleaning interval Only with WASH Adjust value using keys Press enter to confirm Cleaning duration Only with WASH Adjust value using keys Press enter to confirm Contact type Only with WASH N O normally open contact N C normally closed contact Select using keys Press enter to confirm 5 Cycle interval Cleaning Relax time approx 20 s HOLD ...

Страница 100: ... press enter 4 Select CLOCK or TAG using keys press enter 5 All items of this menu group are indicated by the CLK or TAG code Press enter to select menu edit using arrow keys see next page Confirm and proceed using enter 6 Exit Press meas key until the meas mode indicator is displayed Time format Time Day and month Year Tag number 5 6 5 ...

Страница 101: ...t time There is no automatic switchover from winter to summer time Be sure to manually adjust the time Configuration Menu item Action Choices Tag number Select character using keys select next digit using keys Press enter to confirm A Z 0 9 The first 10 characters are seen in the display with out scrolling Tag Number TAG You can enter a designation for the point of measurement tag number in the lo...

Страница 102: ...102 ...

Страница 103: ...libration solution Temperature probe adjustment Note If measurements are performed in fittings with A 110 mm be sure to choose a calibration beaker with the same cross section and of the same material metal plastic Selecting a Calibration Mode Calibration adapts the device to the individual sensor characteristics Access to calibration can be protected with a passcode SERVICE menu First you open th...

Страница 104: ...g an ARF 210 215 flow through fitting you should use the inluded calibration beakers identical dimensions and materials for calibration to prevent calibration errors Display Action Remark Select Calibration Press enter to proceed Select CAL_SOL calibration method Press enter to proceed Ready for calibration Hourglass blinks Display 3 sec Now the device is in HOLD mode Immerse sensor in calibration...

Страница 105: ...t Repeat repeat calibration or Measuring Press enter to confirm With MEAS selected Exit calibration by pressing enter Display of measured variable Sensoface is active After end of calibra tion the outputs remain in HOLD mode for a short time After display of GOOD BYE the device automati cally returns to measuring mode Calibration ...

Страница 106: ...suring mode Then the calibration mode indicator blinks 2 In the second step you enter the measured sample value in the device From the difference between the stored measured value and entered sample value the device calculates the new cell factor If the sample is invalid you can take over the value stored during sampling In that case the old calibration values are stored Afterwards you can start a...

Страница 107: ... Now the device is in HOLD mode The stored value is displayed blinking and can be overwritten with the lab value Press enter to proceed Display of new cell factor and zero point based on 25 C Sensoface is active Press enter To exit calibration Select MEAS then press enter To repeat calibration Select REPEAT then press enter After calibration is ended the device will switch to measuring mode After ...

Страница 108: ...LL calibration method Press enter to proceed Ready for calibration Hourglass blinks Display 3 sec Now the device is in HOLD mode Enter cell factor Press enter to proceed The selected process variable and the temperature are displayed The device shows the calculated cell factor and zero point at 25 C Sensoface is active Use the arrow keys to select MEAS exit REPEAT Press enter to proceed Exit HOLD ...

Страница 109: ...ks Display 3 sec Now the device is in HOLD mode Calibration in air Edit digits until the lower display indicates Zero Calibration with solution Edit digits until the lower display indicates the solution value Press enter to proceed The device shows the cell factor at 25 C and the zero point Sensoface is active Use the arrow keys to select MEAS exit REPEAT Press enter to proceed Exit HOLD is deacti...

Страница 110: ... device is in HOLD mode Enter the measured temperature value Maximum difference 10 K Press enter to proceed Display of actual temperature un compensated in the lower display The corrected tempera ture value is displayed Sensoface is active To exit calibration Select MEAS then press enter To repeat calibration Select REPEAT then press enter After end of calibra tion the outputs re main in HOLD mode...

Страница 111: ... and the active parameter set A B is indicated A B is not displayed with parameter set Fix A Pressing the enter key briefly shows the output currents By pressing the meas key you can step through the following dis plays When no key has been pressed for 60 sec the device returns to the standard display 1 Selecting the parameter set if set to manual in the configuration Select the desired parameter ...

Страница 112: ...no key has been pressed for 60 sec the device returns to the standard display Upper display Controller output Y Secondary display Setpoint Depending on configuration setting conductivity or temperature Note After prolonged power outage 5 days the time display is replaced by dashes and cannot be used for processing Enter the correct time ...

Страница 113: ...113 ...

Страница 114: ...lues VERSION displaying device type software version serial number Access to diagnostics can be protected with a passcode SERVICE menu Note HOLD is not active during Diagnostics mode Action Key Remark Activate Diagnostics Press menu key to call the selection menu Display color changes to turquoise Select DIAG using keys press enter to confirm Select diagnostics option Use keys to select from CALDA...

Страница 115: ...laying the calibration data Select CALDATA using press enter to confirm Use the keys to select the desired parameter from the bottom line of the display The selected parameter is shown in the main display Press meas to return to measurement ...

Страница 116: ...s enter to proceed 2 RAM test Hourglass blinks then display of PASS or FAIL Press enter to proceed 3 EEPROM test Hourglass blinks then display of PASS or FAIL Press enter to proceed 4 FLASH test Hourglass blinks then display of PASS or FAIL Press enter to proceed 5 Module test Hourglass blinks then display of PASS or FAIL Press enter or meas to return to measuring mode ...

Страница 117: ... the date and time Press meas to return to measurement Extended logbook Audit Trail via TAN By using the keys you can scroll backwards and forwards through the extended logbook entries 000 199 000 being the last entry Display CFR Audit Trail also records function activations CAL CONFIG SERVICE some Sensoface messages and opening of the enclosure Display example Displaying the currently measured va...

Страница 118: ...e data you require for requesting a device specific Option Display of device type software hardware version and serial number for all device components Use the keys to switch between software and hardware version Press enter to proceed to next device component ...

Страница 119: ...CODES Assigning and editing passcodes DEFAULT Resetting the device to factory settings OPTION Enabling options via TAN Note HOLD is active during Service mode Action Key Display Remark Activate Service Press menu key to call the selection menu Select SERVICE using keys press enter to confirm Passcode Enter passcode 5555 for service mode using the keys Press enter to confirm Display In service mode...

Страница 120: ...to confirm Enter a valid current value for the respective output using keys Press enter to confirm For checking purposes the actual output current is shown in the bottom right corner of the display Exit by pressing enter or meas Relay test manual test of contacts Select RELAIS using press enter to confirm Now the status of the 4 relays is frozen The 4 digits of the main display represent the respe...

Страница 121: ... value for controller output Yp Enter sign and value in the main display using the keys Press enter to confirm The new value is taken into the lower display Press enter or meas to return to the service menu Return to measurement Press meas once more Controller output 100 0 Relay 2 active Controller output 0 100 Relay 1 active IrDA communication Select IRDA using press enter to confirm When IrDA co...

Страница 122: ... resets the Service passcode to 5555 Reset to factory settings In the SERVICE DEFAULT menu you can reset the device to factory settings NOTICE After a reset to factory setting the device must be reconfigured completely including the sensor parameters Option request Communicate the serial number and hardware software version of your device to the manufacturer These data can be viewed in the Diagnos...

Страница 123: ...123 ...

Страница 124: ...s CAL_SOL Cal solution No CAL_CELL Cell factor No P_CAL Product cal S1 No P_CAL Product cal S2 No CAL RTD Temp adjustm 20 min CONF ParSet A 20 min CONF ParSet B 20 min CONF Passcodes 20 min SERVICE MONITOR 20 min SERVICE OUT 1 20 min SERVICE OUT 2 20 min SERVICE RELAIS 20 min SERVICE CONTROL 20 min Operating States ...

Страница 125: ...status OUT 1 OUT 2 REL1 2 Limit REL1 2 Control ALARM contact WASH contact Time out SERVICE IRDA 22 mA 20 min Cleaning fct No HOLD input No Explanation as configured Last Fix or Last Off active manual Operating States ...

Страница 126: ...H MSOXY Memosens COND Digital MSCOND 0 Memosens COND COND Digital MSCOND MSCOND Memosens Oxy Digital MSOxy 0 Dual COND 2x2 electrode analog Module CC 0 pH ORP value ISM digital TAN Module PH 0 F G Cond 2 4 electrode Module COND 0 Conductivity electrodeless Module CONDI 0 Oxygen ISM digital Traces TAN Module OXY 0 D F TAN options HART SW A001 A Logbook SW A002 B Extended logbook Audit Trail SW A003...

Страница 127: ...ture compensation OFF Without LIN Linear characteristic 00 00 19 99 K reference temp user defined NLF Natural waters to EN 27888 reference temp 25 C 77 F NACL NaCl from 0 to 26 by wt 0 120 C 32 248 F reference temp 25 C 77 F Concentration determination 01 NaCl 0 26 wt 0 C 32 F 0 28 wt 100 C 212 F 02 HCl 0 18 wt 20 C 4 F 0 18 wt 50 C 122 F 03 NaOH 0 13 wt 0 C 32 F 0 24 wt 100 C 212 F 04 H2SO4 0 26 ...

Страница 128: ...mS Sensocheck Monitoring of primary and secondary coils and lines for open circuit and of primary coil and lines for short circuit Delay Approx 30 s Sensoface Provides information on the sensor condition zero point Sensocheck Sensor monitor Direct display of measured values from sensor for validation resistance temperature Temperature input Pt100 Pt1000 NTC 30 kΩ 3 wire connection adjustable Measu...

Страница 129: ... Control input 0 2 V AC DC 10 30 V AC DC Parameter set A Parameter set B FLOW Pulse input for flow measurement 0 100 pulses s Message via 22 mA alarm contact or limit contacts Display 00 0 99 9 l h Output 1 0 4 20 mA max 10 V floating galv connected to output 2 Process variable Conductivity resistivity concentration salinity or temperature Characteristic Linear bilinear or logarithmic Overrange 22...

Страница 130: ...ed range Minimum span LIN 5 of selected range LOG 1 decade Alarm contact Relay contact floating Contact ratings AC 250 V 3 A 750 VA DC 30 V 3 A 90 W Contact response N C fail safe type Response delay 0000 0600 s Wash contact Relay contact floating For controlling a cleaning system Contact ratings AC 250 V 3 A 750 VA DC 30 V 3 A 90 W Contact response N C or N O Interval 000 0 999 9 h 000 0 h cleani...

Страница 131: ...ve action Rate time Td 0000 9999 s 0000 s no derivative action Controller type Pulse length controller or pulse frequency controller Pulse period 0001 0600 s min ON time 0 5 s pulse length controller Max pulse frequency 0001 0180 min 1 pulse frequency controller Real time clock Different time and date formats selectable Power reserve 5 days Display LC display 7 segment with icons colored backlight...

Страница 132: ... test Display test automatic memory test RAM FLASH EEPROM module test Logbook 100 events with date and time Extended logbook TAN Audit Trail 200 events with date and time Service functions Sensor monitor Display of direct sensor signals Current source Current specifiable for output 1 and 2 00 00 22 00 mA Relay test Manual control of the four switching contacts Manual controller Controller output e...

Страница 133: ...0 10 V AC DC4 12 VA 4 W AC 45 65 Hz Overvoltage category II protection class II Nominal operating conditions Ambient temperature 20 55 C Transport Storage temperature 30 70 C Relative humidity 10 95 not condensing Power supply 24 15 230 10 V AC DC DC 80V Frequency for AC 45 65 Hz ...

Страница 134: ...x 148 mm x 117 mm Control panel cutout 138 mm x 138 mm to DIN 43 700 Weight Approx 1200 g 1600 g incl accessories and packaging Cable glands 3 knockouts for M20 x 1 5 cable glands 2 knockouts for NPT or rigid metallic conduit Connections Terminals conductor cross section max 2 5 mm2 User defined 1 Acc to EN 60746 at nominal operating conditions 2 1 count 3 Plus sensor error 4 DC 80 V Specification...

Страница 135: ...468 1 496 1 524 1 552 1 581 1 609 1 638 1 667 1 696 7 15 8 22 9 33 10 48 10 72 10 95 11 19 11 43 11 67 11 91 12 15 12 39 12 64 12 88 13 13 13 37 13 62 13 87 14 12 14 37 14 62 14 88 15 13 15 39 15 64 65 41 74 14 83 19 92 52 94 41 96 31 98 22 100 14 102 07 104 00 105 94 107 89 109 84 111 80 113 77 115 74 1 Data source K H Hellwege Editor H Landolt R Börnstein Zahlenwerte und Funktionen volume 2 part...

Страница 136: ... 5 159 9 164 3 168 8 173 4 177 9 182 6 187 2 191 9 196 7 201 5 206 3 211 2 216 1 221 0 226 0 231 0 236 1 241 1 246 2 251 3 256 5 261 6 266 9 272 1 277 4 282 7 288 0 293 3 298 7 304 1 309 5 5 786 5 965 6 145 6 327 6 510 6 695 6 881 7 068 7 257 7 447 7 638 7 831 8 025 8 221 8 418 8 617 8 816 9 018 9 221 9 425 9 631 9 838 10 047 10 258 10 469 10 683 10 898 11 114 11 332 11 552 11 773 11 995 12 220 12...

Страница 137: ...sses with rapid temperature changes a separate temperature probe with fast response should be used When measuring processes such as dilution or intensification of CIP solutions Clean In Place it is helpful to switch between the param eter sets for measuring the process medium and for measuring the CIP solution 0 18wt 20 C 0 18wt 50 C 02 Substance Concentration ranges NaCl Configuration 0 26wt 0 C ...

Страница 138: ...ntration Curves Conductivity versus substance concentration and process temperature for sodium chloride solution NaCl 01 Sodium chloride solution NaCl 01 Concentration measurement not possible in this range c wt ...

Страница 139: ...ot possible in this range Concentration Curves Conductivity versus substance concentration and process temperature for hydrochloric acid HCl Source Haase Sauermann Dücker Z phys Chem New Edition Vol 47 1965 02 Hydrochloric acid HCl 07 c wt ...

Страница 140: ...tion Curves 03 Sodium hydroxide solution NaOH 10 Conductivity versus substance concentration and process temperature for sodium hydroxide solution NaOH c wt 03 Concentration measurement not possible in this range 10 ...

Страница 141: ...SO4 06 09 Conductivity versus substance concentration and process temperature for sulfuric acid H2SO4 Source Darling Journal of Chemical and Engineering Data Vol 9 No 3 July 1964 c wt 04 09 06 Concentration measurement not possible in this range ...

Страница 142: ...ic acid HNO3 08 Conductivity versus substance concentration and process temperature for nitric acid HN03 Source Haase Sauermann Dücker Z phys Chem New Edition Vol 47 1965 05 Concentration measurement not possible in this range 08 c wt ...

Страница 143: ...143 ...

Страница 144: ...If they are out of range ERR xxx is displayed for 3 sec the display backlighting flashes red the respective maximum or minimum value is shown input must be repeated If a faulty parameter arrives through the interface IrDA HART an error message will be displayed ERR 100 199 the faulty parameter can be localized by pressing the info key Calibration errors If errors occur during calibration an error ...

Страница 145: ...rogram Configuration or calibration data defective completely reconfig ure and recalibrate the device ERR 97 NO MODULE INSTALLED No module Please have the module replaced in the factory ERR 96 WRONG MODULE Wrong module Please have the module replaced in the factory ERR 95 SYSTEM ERROR System error Restart required If error still persists send in the device for repair ERR 100 INVALID SPAN OUT1 Span...

Страница 146: ...ALINITY RANGE SAL 45 0 ERR 13 TEMPERATURE RANGE Temperature range violation ERR 15 SENSOCHECK Sensocheck ERR 60 OUTPUT LOAD Load error ERR 61 OUTPUT 1 TOO LOW Output current 1 0 3 8 mA ERR 62 OUTPUT 1 TOO HIGH Output current 1 20 5 mA ERR 63 OUTPUT 2 TOO LOW Output current 2 0 3 8 mA ERR 64 OUTPUT 2 TOO HIGH Output current 2 20 5 mA ERR 72 FLOW TOO LOW Flow too low ERR 73 FLOW TOO HIGH Flow too hi...

Страница 147: ...Critical values make the Sensoface sad and the correspond ing icon blinks The Sensocheck message is also output as error message Err 15 The alarm contact is active the display backlighting turns red output current 1 is set to 22 mA when configured correspondingly Sensocheck can be switched off during configuration then Sensoface is also disabled Exception After a calibration a smiley is always dis...

Страница 148: ...148 Sensoface Display Problem Status Sensor defect Wrong or defective sensor or excessive cable capacitance see also error message Err 15 Temperature Temperature outside range for TC conc sal ...

Страница 149: ...re Passcodes Access to the device functions is regulated and limited by individually adjustable codes Passcodes see SERVICE This prevents unauthor ized modification of device settings or manipulation of the measure ment results Appropriate use of these passcodes makes them suitable as electronic signature Audit Trail Every manual change of device settings can be automatically docu mented Each chan...

Страница 150: ...13 Approval plates 20 Approvals for application in hazardous locations 133 Assembly 15 Audit Trail explanation 149 Autorange 63 B Backlighting 33 Block diagram 14 C Cable preparation SE 655 SE 656 23 Calibration 103 Calibration by entry of cell factor 108 Calibration with calibration solution 104 Product calibration 106 Calibration data 115 Calibration mode 103 Calibration solutions 135 CIP cleani...

Страница 151: ...tion Alarm 80 CIP SIP cycles 60 CONTROL input 78 Controller 94 Current output 1 62 Current output 2 72 Individual configuration data 52 Limit function 84 Menu groups 45 Output current during Error and HOLD 70 Overview 47 Sensocheck 80 Sensor 56 Tag number 100 Temperature compensation 74 Time and date 100 WASH contact 98 Connection Power supply 21 Sensor 22 Contacts protective wiring 30 CONTROL 78 ...

Страница 152: ... characteristic 91 Current output 2 72 Current start end 63 D Data logger Description 8 View entries 117 Date and time 101 Display 111 Device self test 116 Device type display 118 Diagnostic functions 38 Diagnostics 114 Calibration data 115 Device self test 116 Logbook 117 Sensor monitor 117 Version 118 Dimensions 16 Display 33 Backlighting 33 Display data in Diagnostics mode 114 Display test 116 ...

Страница 153: ...xplosion protection 133 Extended logbook 117 F FDA 21 CFR Part 11 149 FIX output signal in HOLD mode 40 FLASH test 116 FLOW 79 Flow measurement Alarm 82 Configuration 78 H HOLD 38 Exit 40 External activation of HOLD 41 Manual activation of HOLD 41 Output signal during HOLD 40 71 Output signal response 40 Hysteresis 87 89 I Info text 145 Installation instructions 19 Intended use 7 IrDA communicatio...

Страница 154: ...onfiguration 44 Message via CONTROL input 43 Module test 116 Mounting plan 16 Mounting possibilities enclosure 7 O Operating modes 38 Operating mode selection 35 Operating states 124 Option request Conditions 118 Options 122 Enabling 122 Overview 126 Order code 126 Output current curve bilinear 64 Output current fixed value 120 Output current range Output 1 62 Output 2 72 Output filter 68 Output s...

Страница 155: ...idual configuration data 53 Manual selection 46 Selection via external signal 78 Signaling via WASH contact 46 PARSET 46 Passcodes 160 Setting 122 PFC 93 Pipe mounting 17 PLC 93 Point of measurement TAG 101 Power supply 9 Connection 21 Pre assembled special cable 23 Product calibration 106 Product line 126 Protective hood 17 Protective wiring 30 Pulse frequency controller PFC 93 Configuration 95 P...

Страница 156: ...eset to factory settings 122 Return of products under warranty 2 S Safety information 12 Safety instructions 3 SE 655 SE 656 sensor Cable preparation 23 Wiring 24 SE 670 sensor Connection via RS 485 29 Selection menu 35 Sensocheck 147 Configuration 80 Sensoface 147 Sensor compatibility 7 Sensor connection 22 Wiring examples 24 Sensor monitor Diagnostics 117 Service 120 Sensor type selection 56 Ser...

Страница 157: ... Signal lines 21 SIP sterilization cycles configuration 60 Software version display 118 Specifications 127 Specific test report 3 Standard display 36 Start up 12 T TAG 101 TAN options 122 Entering a TAN 122 Overview 126 Technical data 127 Temperature compensation Configuration 74 Temperature probe Adjustment 110 Selection 56 Temperature unit 58 Terminal assignments 20 Overview 14 Terminal plates 2...

Страница 158: ...wer supply 9 User interface 32 W WASH contact Configuration 98 Signaling parameter set 46 Weather protector 17 Wiring Terminal assignments 21 Wiring examples SE 655 SE 656 24 SE 660 25 SE 670 via RS 485 28 Yokogawa IC 40S 27 Yokogawa ISC 40 26 Z Zero calibration 109 ...

Страница 159: ...l reasons they are shown without trademark symbol in this manual Stratos Sensocheck Sensoface Memosens is a registered trademark of Endress Hauser Conducta GmbH and Knick Elektronische Messgeräte GmbH Co KG HART is a registered trademark of the HART Communication Foundation ...

Страница 160: ...s Mode of operation Passcode Service SERVICE 5555 Diagnostics DIAG HOLD mode Calibration CAL Configuration CONF Knick Elektronische Messgeräte GmbH Co KG Beuckestraße 22 14163 Berlin Germany Phone 49 30 80191 0 Fax 49 30 80191 200 info knick de www knick de TA 212 035 KNE03 20181119 Software version 2 x ...