9
9. Technical Data
Input data
Voltage input
± 0 ... 200 V
Overload
Voltage input
limited by 256 V suppressor diode,
max. permissible continuous current ≤ 3 mA
Output data
Output
0 ... ± 10 V, 0 ... ± 20 mA
calibrated selection
Load
for output current
for output voltage
≤12 V
1)
(600 Ω at 20 mA)
≤10 mA (1 kΩ at 10 V)
Offset error
20 µA / 10 mV
Residual ripple
approx. 20 mV
rms
General data
Gain error
< 0.08 % meas. value
typical additional error for AC (45 ... 65 Hz sinus)
0.05 % meas. value
Temperature
coefficient
2)
< 50 ppm/K of final value
Cutoff frequency
approx. 20 kHz
Test voltage
5 kV~ input against output
4 kV~ output against power supply
Working voltage
3)
(basic insulation)
1 kV~for overvoltage category II and
pollution degree 2 to EN 61010-1
For applications with high working voltages, take precautions
to prevent accidental contact and make sure that there is
sufficient distance to adjacent devices or sufficient insulation
between them.