Diaphragm pump PJ25481-950.50.18
Operation
Translation of original Installation Instructions, english, KNF 125530-316634 06/18
19
Ausgangssignal Fehler U
Flt
/ Output signal fault U
Flt
Eingangspegel „high“
Fehler vorhanden
Input level „high“
error detected
[V]
5
[3.9 … 5.5]
Eingangspegel „low“
kein Fehler
Input level „low“
no error
[V]
0
[0 … 0.9]
Max. Strombelastbarkeit
Max. current carrying capacity
[mA]
10
Ausgangsimpedanz @ 1kHz
Output impedance @ 1kHz
[k
Ω]
≥ 9
Eingangssignal Remote EIN/AUS U
Rmt
/ Input signal Remote ON/OFF U
Rmt
Eingangspegel „high“
Motor EIN
Input level „high“
motor ON
[V]
5
[3.9 … 5.5]
Eingangspegel „low”
Motor AUS
Input level „low”
motor OFF
[V]
0
[0 … 0.9]
Eingangsimpedanz @ 1 kHz
Input impedance @ 1 kHz
[k
Ω]
≥ 1.8
Versorgung Gasballastventil U
+GB
/ Supply gas ballast valve U
+GB
Steuerspannung DC
Control voltage DC
[V]
24 ± 10%
Max. Stromaufnahme
Max. current consumption
[mA]
≤ 50
Tab. 9 (part 3): Connection plan motor electronics
The flow rate can be varied by an external actuation (Sub-D-plug,
The speed of the pump is controlled by a control voltage.
Please contact our KNF customer service for further information.
Remote ON/OFF is through an 9-pin controller connection (Pin 8,
To start the motor, Pin 5 must be bridged to the ground of the
controller connection.
Please contact our KNF customer service for further information.
Switching off the pump
The life of the diaphragm is prolonged the formation of condensate
is avoided. Therefore the following precautions should be taken:
Run the pump for a few minutes to warm it up before handling
saturated or nearly saturated vapors.
KNF recommends: When transferring aggressive media, flush
the pump prior to switch off (see Chapter 8.2.1) to increase the
service life of the diaphragm.
Switch off pump with power switch (Fig. 1 at Chapter 5).
Restore the system to normal atmospheric pressure (release
pneumatic pressure in pump).
Pull out the pump’s main plug.
Adjusting the flow rate
Remote ON/OFF
Vapors as media