Swing Piston Pumps NPK 04 

 

Installation and connection 

Translation of original Operating and Installation Instructions, english, KNF 121571-121574 06/14 

5.  Installation and connection 

Only install and operate the pump under the operating parameters 
and conditions described in Chapter 4, Technical data. 

 

Observe the safety precautions (see Chapter 3). 

 

5.1.  Installation 

  Before installation, store the pump at the installation location to 

bring it up to room temperature. 

  See the data sheet for the mounting dimensions.  

  Make sure that the installation location is dry and the pump is 

protected against rain, splash, hose and drip water. 

  Install the pump at the highest point in the system to prevent 

condensate from collecting in the pump head. 

  Protect the pump from dust. 

  Protect the pump from vibrations and jolts. 

 

 

5.2.  Electrical connection 

 

DANGER 

 Extreme danger from electrical shock 

  Only have the pump connected by an authorized 

specialist. 

  Only have the pump connected when the power 

supply is disconnected. 

 

  In the electrical installation, arrangements (complying with EN 

60335-1) must be made for disconnecting the pump motor 
from the electrical supply. 

 

Connecting pump 

1.   Compare the supply data with the data on the motor-plate. For 

operating current see type plate. 

 

The voltage must not vary by more than + 10% and - 10% from 
that shown on the type-plate. 

 

2.   Connect the plus and minus pole. 

 

With DC motors, note the proper polarity:  
red motor cable: + 
black motor cable: - 

 

 

EMC-compatible Installation (brushless DC motor) 

In order to remove the electrical interference according to EN 
55014-1:1993 + A1:1997 all pumps with brushless DC motor (DC 
B) must be equipped with an additional electronic circuit. This 
electronic circuit has to be installed as close to the motor as possi-
ble. 

The additional circuitry is not necessary if a voltage supply has a 
suppression of > 20 dB at 150 kHz and 0 dB at 1 MHz. 

Mounting dimensions 

Installation location 

Содержание NPK 04 DC

Страница 1: ...n Instructions Read and observe these Oper ating and Installation Instruc tions Contents Page 1 About this document 2 2 Use 3 3 Safety 4 4 Technical Data 6 5 Installation and connection 7 6 Operation...

Страница 2: ...ere Possible consequences of a failure to observe the warning are specified here The signal word e g Warning indicates the danger level Measures for avoiding the danger and its conse quences are speci...

Страница 3: ...ether the medium can be transferred danger free in the specific application case Before using a medium check the compatibility of the materials of the pump head swing piston and piston seal with the m...

Страница 4: ...all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental protection regulations Observe the respective national and inter national regul...

Страница 5: ...5 The pumps conform to the EC Directive 2004 108 EC concerning Electromagnetic Compatibility The following harmonized standards have been used NPK 04 DC NPK 04 DCB DIN EN 55014 1 2 DIN EN 55014 1 DIN...

Страница 6: ...Delivery rate at atm pressure l min 3 3 Tab 4 Liters in standard state 1 013 mbar NPK 04 DC Pressure NPK 04 DCB Pressure Parameter Value Max permissible operating pressure bar g 1 0 Ultimate vacuum mb...

Страница 7: ...electrical shock Only have the pump connected by an authorized specialist Only have the pump connected when the power supply is disconnected In the electrical installation arrangements complying with...

Страница 8: ...al circuit 5 3 Pneumatic connection Only connect components to the pump which are designed for the pneumatic data of the pump see Chapter4 Technical da ta If the pump is used as a vacuum pump safely d...

Страница 9: ...n the pres sure line is throttled or regulated make sure that the maximum permissible operating pressure is not exceeded Watch pressure during operation If the pressure reaches the maximum permissi bl...

Страница 10: ...ure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet Cause Fault remedy Condensate has collected in pump head Install pump at highest point in s...

Страница 11: ...to KNF Customer Service see last page for the ad dress In order for KNF to repair the pump the customer must provide a statement on the media which were pumped and on pump clean ing Please fill out t...

Страница 12: ...safety clearance and decontamination form For optimal processing of a return a copy of this declaration should be sent in advance via e mail regular mail or fax to KNF Customer Service refer to final...

Страница 13: ...s NPK 04 Health and safety clearance and decontamination form Translation of original Operating and Installation Instructions english KNF 121571 121574 06 14 13 10 Health and safety clearance and deco...

Страница 14: ......

Страница 15: ......

Страница 16: ...oss Shinkawa Bldg Annex 3F 1 16 14 Shinkawa Chuo ku Tokyo Japan 104 0033 Tel 0081 0 3 3551 7931 Fax 0081 0 3 3551 7932 E mail info knf co jp www knf co jp Korea KNF Neuberger Ltd Woosan Bldg RM 202 33...

Отзывы: