KNF FL 10 Скачать руководство пользователя страница 10

Maintenance 

 

Installation Instructions FL 10  

 

KNF Flodos 173856_MA_FL10_EN_01.docx1 

10

 

 

5  Maintenance 

This product contains no parts that can be replaced and it cannot 
be maintained. 
 

6  Rectifying transfer problems 

Symptom 

Cause 

Remedy 

Pump does not work, 
no movement or 
sounds detectable 

No or incorrect control 

Check that voltage and signal form comply 
with the specification 

Pump does not work, 
drive is very hot 

The coil is controlled with 
DC voltage or another, 
incorrect signal form 

Check that voltage and signal form comply 
with the specification 

The pump does not 
suck or vacuum is 
insufficient 

External valve is closed 

Check external valve 

Counter pressure on 
pressure side is too high 

Change the pressure conditions on the 
pressure side 

Particles in the pump head  Rinse the pump head 

Use a preventive preliminary filter 

Pump does not trans-
fer 

External valve is closed or 
filter is clogged or too 
small 

Check external valves and filter 

Connections or hoses are 
blocked 

Check connections and hoses 
Remove blockage. 

Flow rate is insuffi-
cient or unstable 

Incorrect control 

Check that voltage and signal form comply 
with the specification 

Cross-section of hydraulic 
hoses or connectors too 
narrow or restricted 

Disconnect the pump from the system and 
determine output values 
Remove restriction (e.g. valve) if neces-
sary. 
If applicable, use larger-diameter hoses or 
connectors 

Higher counter pressure in 
the system than assumed 
for the design 

Contact KNF representative 

Particles in the pump head  Rinse the pump head 

Use a preventive preliminary filter 

Pump has reached the 
end of its service life 

Replace the pump 

Leak of pump head 

Diaphragm or oscillating 
diaphragm defective 

Replace the pump 

If the malfunction cannot be rectified, contact your local KNF 
representative (

www.knf.com

 

 

Содержание FL 10

Страница 1: ...FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC P FL 10 AC Before operating the pump please read the Installation Instructions and safety precautions...

Страница 2: ...1 5 Supporting documents 4 2 Safety 5 2 1 Intended use 5 2 2 Reasonably foreseeable misuse 5 2 3 Responsibility of the user 5 2 4 Product specific risks 5 3 Installation 7 3 1 Installation location 7...

Страница 3: ...or PML there may be differences from the Installation Instructions 1 2 Warnings Warnings in the Installation Instructions are marked by the hazard symbol the keywords and the color These features pro...

Страница 4: ...improper handling The manufacturer accepts no liability for damage or malfunctions that are caused by using spare parts or accessories that are not approved by the manufacturer 1 4 Manufacturer s add...

Страница 5: ...warnings in this section and in the other sections of the Installation Instructions must be observed to prevent dangerous situations DANGER Danger of injuries and damage to property due to dangerous...

Страница 6: ...mp in accordance with the technical data DANGER Danger of injuries and damage to property due to uncon trolled flow while the pump is not in operation Poisoning and chemical burns or unintended reacti...

Страница 7: ...ion 3 1 Installation location The installation location must protect the pump against immersion keep aggressive and flammable liquids and vapors away allow hoses to be connected without tensile or ben...

Страница 8: ...to the correct voltage Operate the pump in accordance with the technical data Take suitable precautions to limit maximum power con sumption 3 4 2 AC coils DANGER Danger from electric shock Connect the...

Страница 9: ...al reactions with water Residues of water in the pump that come from testing in the factory may react with the transferred medium Before starting the pump for the first time rinse it with a medium tha...

Страница 10: ...e a preventive preliminary filter Pump does not trans fer External valve is closed or filter is clogged or too small Check external valves and filter Connections or hoses are blocked Check connections...

Страница 11: ...ertakes to repair the pump only under the condition that the customer provides a certificate of the pumped medium and cleaning of the pump For this purpose please follow the instruc tions on www knf c...

Страница 12: ...www knf com...