5 Maintenance
This product contains no parts that can be replaced and it cannot
be maintained.
6 Rectifying transfer problems
Symptom
Cause
Remedy
Pump does not work,
no movement or
sounds detectable
No or incorrect control
Check that voltage and signal form comply
with the specification
Pump does not work,
drive is very hot
The coil is controlled with
DC voltage or another,
incorrect signal form
Check that voltage and signal form comply
with the specification
The pump does not
suck or vacuum is
insufficient
External valve is closed
Check external valve
Counter pressure on
pressure side is too high
Change the pressure conditions on the
pressure side
Particles in the pump head Rinse the pump head
Use a preventive preliminary filter
Pump does not trans-
fer
External valve is closed or
filter is clogged or too
small
Check external valves and filter
Connections or hoses are
blocked
Check connections and hoses
Remove blockage.
Flow rate is insuffi-
cient or unstable
Incorrect control
Check that voltage and signal form comply
with the specification
Cross-section of hydraulic
hoses or connectors too
narrow or restricted
Disconnect the pump from the system and
determine output values
Remove restriction (e.g. valve) if neces-
sary.
If applicable, use larger-diameter hoses or
connectors
Higher counter pressure in
the system than assumed
for the design
Contact KNF representative
Particles in the pump head Rinse the pump head
Use a preventive preliminary filter
Pump has reached the
end of its service life
Replace the pump
Leak of pump head
Diaphragm or oscillating
diaphragm defective
Replace the pump
If the malfunction cannot be rectified, contact your local KNF
representative (