PCB PARAMETERS
THE PARAMETERS STORED ON THE PCB ARE ESSENTAL FOR THE CORRECT OPERATION OF THE
STOVE.
THE PARAMETERS SHOWN BELOW ARE STORED DURING THE STOVE TESTING PHASE DIRECTLY
AT THE FACTORY.
THESE PARAMETERS STEM FROM ACCURATE TESTS WITH VARIOUS TYPES OF PELLETS AND
MUST NOT BE MODIFIED WITHOUT PRIOR AUTHORISATION FROM KLOVER srl, IN ORER TO AVOID
JEOPARDISING THE STOVE'S OPERATION.
THE COMPANY SHALL NOT BE HELD LIABLE FOR ANY DAMAGES CAUSED BY INCORRECT
PARAMETER ENTRY.
“Factory calibrations” (Menu M8 – 1) (Firmware H01_050515)
Parameter
Description
Display text
Unit of
measurement
Value field
Database o0
Pr01
Ignition cycle maximum time
IGNITION MINUTES
Minutes
5 – 25
20
Pr02
Start time
START MINUTES
Minutes
2 – 20
4
Pr03
Time interval between the two brazier
cleaning operations
CLEANING
FREQUENCY
Minutes
10 – 255
60
Pr04
Screw feed gearmotor ON time in ignition
phase
SCREW FEED ON
Seconds
0.1 – 4.0
1.0
Pr05
Screw feed gearmotor ON time in start
phase
SCREW FEED START
Seconds
0.1 – 4.0
0.8
Pr06
Screw feed gearmotor ON time in power 1
work phase
P1 SCREW FEED
Seconds
0.1 – 4.0
1.0
Pr07
Screw feed gearmotor ON time in power 5
work phase
P5 SCREW FEED
Seconds
0.1 – 4.0
2.8
Pr08
Flue gas extraction speed in brazier
cleaning phase
EXTRACTOR
CLEANING
RPM
700 – 2800
2800
Pr09
Screw feed gearmotor ON time in
cleaning phase
CLEANING SCREW
FEED
Seconds
0.0 – 4.0
0.8
Pr10
Flue gas extractor switch-off threshold (in
switch-off phase)
THRESHOLD OFF
°C
50 – 180
70
Pr11
Alarm delay
ALARMS DELAY
Seconds
20 – 90
30
Pr12
Brazier cleaning duration
CLEANING DURATION
Seconds
0 – 120
50
Pr13
Flue gas minimum temperature for
considering the stove on
MINIMUM THRESHOLD
°C
35 – 180
43
Pr14
Flue gas maximum temperature
MAXIMUM
THRESHOLD
°C
60 – 280
250
Pr15
Flue gas temperature threshold for
starting the heat exchangers
FAN THRESHOLD
°C
50 – 210
60
Pr16
Flue gas extraction speed in ignition
phase
EXTRACTOR ON
RPM
500 – 2800
2200
Pr17
Flue gas extraction speed in start phase
EXTRACTOR START
RPM
500 – 2800
1900
Pr18
Flue gas extraction speed in power 1 work
phase
EXTRACTOR P1
RPM
500 – 2800
1400
Pr19
Flue gas intake speed in power 5 work
phase
EXTRACTOR P5
RPM
500 – 2800
1900
Pr20
Heat exchanger 1 motor speed in power 1
work phase
AIR P1
Volt
65 – 225
180
Pr21
Heat exchanger 1 motor speed in power 5
work phase
AIR P5
Volt
65 – 225
225