50
AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE
EN - Rev. 1.6
Pr05
M10 – 05 – 05 Screw feed gear motor ON time in stabilisation phase
SC.F. STABILISE
Seconds
0.1 – 8.0
1,2
Pr06
M10 – 05 – 06 Screw feed gear motor ON time in power 1 work phase
SC.F. POWER 1
Seconds
0.1 – 8.0
1,8
Pr07
M10 – 05 – 07 Screw feed gear motor ON time in power 2 work phase
SC.F. POWER 2
Seconds
0.1 – 8.0
2,4
Pr08
M10 – 05 – 08 Screw feed gear motor ON time in power 3 work phase
SC.F. POWER 3
Seconds
0.1 – 8.0
3,0
Pr09
M10 – 05 – 09 Screw feed gear motor ON time in power 4 work phase
SC.F. POWER 4
Seconds
0.1 – 8.0
3,8
Pr10
M10 – 05 – 10 Screw feed gear motor ON time in power 5 work phase
SC.F. POWER 5
Seconds
0.1 – 8.0
4,5
Pr11
M10 – 05 – 11 Time after which an alarm is triggered in the event of a fault
DEL. ALARMS
Seconds
0 – 120
90
Pr12
M10 – 05 – 12 Brazier cleaning duration
CLEANING DURATION
Seconds
0 – 120
60
Pr13
M10 – 05 – 13 Combustion chamber minimum temperature in order to consider the
appliance on
MINIMUM THRESHOLD
°C
70 – 280
180
Pr14
M10 – 05 – 14 Combustion chamber maximum temperature
MAXIMUM
THRESHOLD
°C
200 – 880
800
Pr15
M10 – 05 – 15 Combustion chamber temperature threshold for starting the air
exchangers
AIR THRESH.
°C
100 – 720
180
Pr16
M10 – 05 – 16 Flue gas extraction speed in ignition phase
SPE. IGNIT. FLUE GAS
RPM
500 – 2800
1900
Pr17
M10 – 05 – 17 Flue gas extraction speed in start phase
SPE. STAB. FLUE GAS
RPM
500 – 2800
2000
Pr18
M10 – 05 – 18 Flue gas extraction speed in power 1 work phase
SPE. FLUE GAS P.1
RPM
500 – 2800
1500
Pr19
M10 – 05 – 19 Flue gas extraction speed in power 2 work phase
SPE. FLUE GAS P.2
RPM
500 – 2800
1650
Pr20
M10 – 05 – 20 Flue gas extraction speed in power 3 work phase
SPE. FLUE GAS P.3
RPM
500 – 2800
1800
Pr21
M10 – 05 – 21 Flue gas extraction speed in power 4 work phase
SPE. FLUE GAS P.4
RPM
500 – 2800
1900
Pr22
M10 – 05 – 22 Flue gas extraction speed in power 5 work phase
SPE. FLUE GAS P.5
RPM
500 – 2800
2100
Pr23
M10 – 05 – 23 Heat exchanger 1 speed (primary) in power 1 work phase
SPE. AIR P.1
Volt
65 – 225
190
Pr24
M10 – 05 – 24 Heat exchanger 1 speed (primary) in power 2 work phase
SPE. AIR P.2
Volt
65 – 225
190
Pr25
M10 – 05 – 25 Heat exchanger 1 speed (primary) in power 3 work phase
SPE. AIR P.3
Volt
65 – 225
200
Pr26
M10 – 05 – 26 Heat exchanger 1 speed (primary) in power 4 work phase
SPE. AIR P.4
Volt
65 – 225
210
Pr27
M10 – 05 – 27 Heat exchanger 1 speed (primary) in power 5 work phase
SPE. AIR P.5
Volt
65 – 225
225
Pr28
M10 – 05 – 28
Combustion chamber temperature threshold for considering the appliance
off
THRESHOLD OFF
°C
50 – 250
170
Pr29
M10 – 05 – 29 Flue gas extraction speed in brazier cleaning phase
SPE. FLUE GAS
CLEAN.
RPM
700 – 2800
2800
Pr30
M10 – 05 – 30 Screw feed gear motor ON time in cleaning phase
SC.F. CLEAN
Seconds
0.0 – 8.0
1,0
Pr31
M10 – 05 – 31 Enable a primary room temperature sensor connected to the card
CARD SENSOR
On – Off
On – Off
Off
Pr32
M10 – 05 – 32 Preheating time
PREHEAT. TIME
Seconds
0 – 250
0
Pr33
M10 – 05 – 33 PELLET CRUISE CONTROL modulation threshold
CRUISE THRESH.
°C
120 – 880
560
Pr34
M10 – 05 – 34 PELLET CRUISE CONTROL modulation threshold Temperature Delta
CRUISE DELTA
°C
20 – 60
40
Pr35
M10 – 05 – 35 PELLET CRUISE CONTROL modulation time
CRUISE TIME
Minutes
1 – 10
3
Pr36
M10 – 05 – 36 Time after which C.A.T. maintenance operation is requested.
SERVICE HOURS
Hours
Off
260 – 2800
2000
Parameters “RELAX CALIBRATIONS” – Mod. AC80 / CLC90
(L09_161018)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
o2
Pr150
M10 – 10 – 01
Heat exchanger 1 speed (primary) in work phase with
“RELAX
FUNCTION”
active
SPE. AIR RELAX
Volt
Off
65 – 225
Off
Pr151
M10 – 10 – 02
“RELAX FUNCTION”
activation time
TEMPS RELAX
Minutes
30 – 254
On
30
Содержание AURA 120
Страница 2: ......
Страница 11: ...6 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 80...
Страница 12: ...7 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions CLASS 90...
Страница 13: ...8 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 120...
Страница 14: ...9 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions REA 100...
Страница 62: ...57 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 WIRING DIAGRAM...
Страница 65: ...60 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Страница 66: ...61 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Страница 67: ...62 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...
Страница 68: ...Cod CS IST A80 EN KLOVER Srl Via A Volta 8 37047 San Bonifacio VR VAT No 02324280235 www klover it...