background image

ENGLISH      

 

 

 

 

 

AURA 80, 
CLASS 90, 
AURA 120, 
REA 100 

pellet-burning 
stove 

INSTALLATION, USE, 
MAINTENANCE AND HELPFUL 
TIPS 

 

Содержание AURA 120

Страница 1: ...ENGLISH AURA 80 CLASS 90 AURA 120 REA 100 pellet burning stove INSTALLATION USE MAINTENANCE AND HELPFUL TIPS...

Страница 2: ......

Страница 3: ...85 PERFORMANCE FEATURES PERFORMANCE Fire resistance A1 Distance from combustible material 200 mm Fuel spillage risk Compliant Emission of combustion products Nominal power Reduced power CO at 13 of O2...

Страница 4: ...RES PERFORMANCE Fire resistance A1 Distance from combustible material 200 mm Fuel spillage risk Compliant Emission of combustion products Nominal power Reduced power CO at 13 of O2 0 008 CO at 13 of O...

Страница 5: ...PERFORMANCE Fire resistance A1 Distance from combustible material 200 mm Fuel spillage risk Compliant Emission of combustion products Nominal power Reduced power CO at 13 of O2 0 010 CO at 13 of O2 0...

Страница 6: ...LLATION 17 POSITIONING 17 SPACES AROUND AND ABOVE THE APPLIANCE 18 EXTERNAL AIR INTAKE 18 THE FLUE AND CONNECTION TO THE SAME 19 CHIMNEY 20 ELECTRICAL CONNECTION 21 CONNECTION TO THE ROOM THERMOSTAT O...

Страница 7: ...sfied with this product Please carefully read the warranty certificate on the last page of this User guide The manual contains a detailed description of the appliance and its operation instructions fo...

Страница 8: ...he use of poor quality pellets or any other material can damage the appliance operation voiding the warranty and exempting the manufacturer from all liability Do not use the appliance as an incinerato...

Страница 9: ...NS SET OUT IN THE SPECIFIC LAWS IN FORCE IN THE COUNTRY WHERE THE MACHINE IS INSTALLED MUST BE OBSERVED NON ROUTINE MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORISED AND QUALIFIED STAFF To ensure the v...

Страница 10: ...roswitch for closing tank cover Anti interference filter Main switch connection for power supply cable with 2 built in fuses 4A 250V Flue gas outlet Intake pipe Support panel Wi Fi information Mac add...

Страница 11: ...6 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 80...

Страница 12: ...7 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions CLASS 90...

Страница 13: ...8 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions AURA 120...

Страница 14: ...9 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 Overall dimensions REA 100...

Страница 15: ...REA 100 PELLET BURNING STOVE EN Rev 1 6 Connections data sheet AURA 80 Description of connections C Ducted air outlet MULTI AIR model only 80 mm M A Intake pipe 50 mm S Flue gas outlet 80 mm M E Elec...

Страница 16: ...REA 100 PELLET BURNING STOVE EN Rev 1 6 Connections data sheet CLASS 90 Description of connections C Ducted air outlet MULTI AIR model only 80 mm M A Intake pipe 50 mm S Flue gas outlet 80 mm M E Elec...

Страница 17: ...STOVE EN Rev 1 6 Connections data sheet AURA 120 Description of connections C1 Ducted air outlet 1 MULTI AIR model only 80 mm M C2 Ducted air outlet 2 MULTI AIR model only 80 mm M A Intake pipe 50 mm...

Страница 18: ...REA 100 PELLET BURNING STOVE EN Rev 1 6 Connections data sheet REA 100 Description of connections A Intake pipe 50 mm Sb Rear Flue gas outlet 80 mm M Su Upper Flue gas outlet 80 mm F E Electricity co...

Страница 19: ...meter mm 80 Air intake pipe diameter mm 50 Minimum chimney draught at nominal thermal power Pa 10 Minimum chimney draught at reduced thermal power Pa 10 Combustion gas mass at nominal thermal power g...

Страница 20: ...nal frequency Hz 50 Flue outlet diameter mm 80 Air intake pipe diameter mm 50 Minimum chimney draught at nominal thermal power Pa 10 5 Minimum chimney draught at reduced thermal power Pa 10 Combustion...

Страница 21: ...bustion gas mass at reduced thermal power g s 3 4 Ventilated pellet tank capacity ducted kg 20 16 Average exhaust flue gas temperature at nominal thermal power C 119 7 Average exhaust flue gas tempera...

Страница 22: ...HE PLACE OF INSTALLATION Positioning The initial phase for best installation of the appliance is to determine its optimum location the following elements need to be considered The possibility of creat...

Страница 23: ...all behind the appliance is on the outside we recommend you make the hole near it at about 20 cm above the ground see example in Fig A If it is not possible to put an air vent in the wall behind the a...

Страница 24: ...free and independent internal cross section Rectangular cross sections must have a maximum ratio of 1 5 between the sides If the flue is installed externally it must be insulated in order to prevent...

Страница 25: ...duct the flue using a stainless steel pipe properly insulated with rock wool or vermiculite and sized according to the route The connection to the flue must be appropriately sealed When assembling the...

Страница 26: ...e s safety is ensured when it is properly connected to an efficient earthing system In the electric connection to the mains power supply include a 6 A Id 30 mA differential trip switch with suitable b...

Страница 27: ...thermostats are satisfied Ducted fan 1 will switch to modulation mode in any case With Room sensor Pr56 must be enabled with value S1 or S1 2 Once the SET ROOM 1 temperature setting is reached Menu 12...

Страница 28: ...of the selected menu item Decreases the room temperature setting operating power In SET DUCTING mode it modifies the value of ducting 1 3 ON OFF On the first press Activates the display Working Switc...

Страница 29: ...Ds on the support panel work LED Description Status Action 1 ON OFF Off The appliance is off Flashing The appliance is shutting down On The appliance is on 2 and 3 POWER STATUS Led 2 On Led 3 Off Powe...

Страница 30: ...ettings 1 3 or 5 With the help of LEDs 2 and 3 Power status you can check the set power setting see LED table Display The remote control display shows information concerning the operating status of th...

Страница 31: ...nce once the SET ROOM temperature setting has been reached is excluded The operating power will however be modulated the display will show the word MODULATION If enabled the appliance will enter modul...

Страница 32: ...d 2 Increase and Decrease allow you to modify the selected value Key 4 Set selects the subsequent value Key 5 Esc selects the previous value Key 3 ON OFF takes you back to the previous menu item Numbe...

Страница 33: ...the screen display for the enabling days Key 1 Increase enables the selected day Key 2 Decrease disables the selected day Key 4 Set selects the subsequent day Key 5 Esc selects the previous day Key 3...

Страница 34: ...selects the subsequent value Key 5 Esc selects the previous value Key 3 ON OFF takes you back to the previous menu item Menu 04 Language Allows you to select the dialogue language from the available...

Страница 35: ...low shows the various devices and their meanings Display Meaning L04 270218 example Firmware code loaded in the control unit ARIA 1 0 example Firmware code loaded in the remote control F GS T Indicate...

Страница 36: ...en for the WiFi card The table below shows the various items and their meanings Display Meaning Values displayed SIGNAL Indicates the value of the Wifi signal detected by the reception card 0 100 CHAN...

Страница 37: ...sonal injuries Menu 11 Relax function Menu not available Allows for reducing the front air fan speed for a pre set time 90 min Menu 12 Set Room Duc Menu displayed only on models with this function All...

Страница 38: ...chapter 1 Power the appliance using the main ON OFF switch on the rear of the appliance 2 Check that in Menu 08 WIFI STATUS on the remote control that the item WIFI STATUS shows a value of 02 Access...

Страница 39: ...to connect the appliance to the Internet from the list and enter the password for the selected network If the network is hidden click on the item Custom SSID and enter the required parameters 8 Click...

Страница 40: ...ng registration You can now enter a new device by clicking on Add stove in the main menu During this procedure you will need the ITEM CODE Model and SERIAL NUMBER for your appliance shown on the CE la...

Страница 41: ...STABILISATION Flame stabilisation allowing uniform ignition of all pellets unburnt during the previous stages Approx 8 minutes At the end of the ignition cycle the appliance switches to working mode...

Страница 42: ...s between 07 C and 40 C can be set Pressing key 3 On Off or waiting a few seconds without confirming will mean that the set value is not saved During this operation the display will appear as in the f...

Страница 43: ...e to modify the value for the ducted air fan for zone 2 and confirm by pressing key 4 Set or 5 Esc the value can be set manually from 1 to 5 or set to automatic A connected with the value set in SET P...

Страница 44: ...check the seal on the flue gas pipes and the filter of the ash vacuum device used for cleaning What happens if the pellets do not ignite If the ignition fails the display will show the alarm message I...

Страница 45: ...s occurs when the encoder tachometer in the extractor detects an extractor speed equal to 0 AL 05 IGNIT FAILED No ignition This occurs when the minimum temperature in the combustion chamber Pr13 is no...

Страница 46: ...irective 89 391 EEC The required cleaning frequency depends on the type and quality of the pellets used The schedule indicated below may therefore vary Any problem affecting the appliance caused by la...

Страница 47: ...anger cleaning hook to lift the rod and move it backwards and forwards to clean the air heat exchanger of combustion residues figure 3 Empty the ash drawer Figure 4 The ash tray on AURA 120 and REA 10...

Страница 48: ...gure 7 WARNING use suitable ash vacuum devices equipped with a fine mesh filter in order to prevent ash from being blown into the room and to prevent damaging the vacuum cleaner We do not recommend th...

Страница 49: ...8 After having removed the two inspection plates in the picture figure 9 clean the right and left flue gas conduits with a brush figure 10 Remove the front panel below To remove it unscrew both screws...

Страница 50: ...ction vent unscrewing the two screws figure 14 After having removed the vent vacuum the residues inside the compartment figure 15 To ensure correct operation it is necessary to remove the sawdust depo...

Страница 51: ...nning of winter and whenever it becomes necessary It is important to check for any obstructions in the flue before switching the appliance on following long periods of inactivity If the flue is not cl...

Страница 52: ...d ducting 1 in power 4 work phase SPE DUC 1 P 4 Volt 65 225 65 Pr61 M10 03 07 Heat exchanger 2 speed ducting 1 in power 5 work phase SPE DUC 1 P 5 Volt 65 225 65 Pr62 M10 03 08 Heat exchanger 3 speed...

Страница 53: ...hase SPE FLUE GAS P 1 RPM 500 2800 1500 Pr19 M10 05 19 Flue gas extraction speed in power 2 work phase SPE FLUE GAS P 2 RPM 500 2800 1650 Pr20 M10 05 20 Flue gas extraction speed in power 3 work phase...

Страница 54: ...Heat exchanger 3 speed ducting 2 in power 4 work phase SPE DUC 2 P 4 Volt 65 225 65 Pr66 M10 03 12 Heat exchanger 3 speed ducting 2 in power 5 work phase SPE DUC 2 P 5 Volt 65 225 65 Parameters VARIOU...

Страница 55: ...10 05 21 Flue gas extraction speed in power 4 work phase SPE FLUE GAS P 4 RPM 500 2800 1900 Pr22 M10 05 22 Flue gas extraction speed in power 5 work phase SPE FLUE GAS P 5 RPM 500 2800 2100 Pr23 M10 0...

Страница 56: ...speed ducting 2 in power 4 work phase SPE DUC 2 P 4 Volt 65 225 65 Pr66 M10 03 12 Heat exchanger 3 speed ducting 2 in power 5 work phase SPE DUC 2 P 5 Volt 65 225 65 Parameters VARIOUS CALIBRATIONS M...

Страница 57: ...1 M10 05 21 Flue gas extraction speed in power 4 work phase SPE FLUE GAS P 4 RPM 500 2800 2250 Pr22 M10 05 22 Flue gas extraction speed in power 5 work phase SPE FLUE GAS P 5 RPM 500 2800 2400 Pr23 M1...

Страница 58: ...hanger 3 speed ducting 2 in power 4 work phase SPE DUC 2 P 4 Volt 65 225 220 Pr66 M10 03 12 Heat exchanger 3 speed ducting 2 in power 5 work phase SPE DUC 2 P 5 Volt 65 225 225 Parameters VARIOUS CALI...

Страница 59: ...M10 05 21 Flue gas extraction speed in power 4 work phase SPE FLUE GAS P 4 RPM 500 2800 2250 Pr22 M10 05 22 Flue gas extraction speed in power 5 work phase SPE FLUE GAS P 5 RPM 500 2800 2400 Pr23 M10...

Страница 60: ...speed ducting 2 in power 4 work phase SPE DUC 2 P 4 Volt 65 225 65 Pr66 M10 03 12 Heat exchanger 3 speed ducting 2 in power 5 work phase SPE DUC 2 P 5 Volt 65 225 65 Parameters VARIOUS CALIBRATIONS Mo...

Страница 61: ...1 M10 05 21 Flue gas extraction speed in power 4 work phase SPE FLUE GAS P 4 RPM 500 2800 2150 Pr22 M10 05 22 Flue gas extraction speed in power 5 work phase SPE FLUE GAS P 5 RPM 500 2800 2300 Pr23 M1...

Страница 62: ...57 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6 WIRING DIAGRAM...

Страница 63: ...r it The Klover Warranty will remain in effect for a period of 2 years from the date of purchase if proven by a delivery note or other proof of purchase e g receipt stating the name of the seller the...

Страница 64: ...ated to improper functioning of the chimney flue Defects in the Product caused by negligence accidental breakage normal wear and tear tampering and or damage during transport scratches dents etc inclu...

Страница 65: ...60 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...

Страница 66: ...61 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...

Страница 67: ...62 AURA 80 CLASS 90 AURA 120 REA 100 PELLET BURNING STOVE EN Rev 1 6...