Unitronics Industrial Automation 

 IO-DI8-RO4, IO-DI8-RO4-L

  

 

I/O Expansion Modules   8 Inputs, 4 Outputs

The IO-DI8-RO4 and IO-DI8-RO4-L are I/O 
expansion modules that can be used in 
conjunction with specific Unitronics OPLC 
controllers. 
The modules are identical except for their 
voltage specifications: IO-DI8-RO4 runs at 
24 VDC; IO-DI8-RO4-L at 12 VDC. 
Both modules offer 8 digital inputs, type 
pnp/npn (source/sink), and 4 relay outputs. 
The interface between a module and the 
OPLC is provided by an adapter. 
These modules may either be snap-
mounted on a DIN rail, or screw-mounted 
onto a mounting plate.

 

Component identification 

1 Module-to-module 

connector 

Communication status indicator 

Outputs’ power supply  
connection points 

Output connection points 

Input/Output status indicators 

Module-to-module connector port 

Input connection points 

1

6

7

2

3

5

4

IO-DI8-RO4

„

Before using this product, it is the responsibility of the user to read and understand this document and
any accompanying documentation.

„

All examples and diagrams shown herein are intended to aid understanding, and do not guarantee
operation.  Unitronics accepts no responsibility for actual use of this product based on these examples.

„

Please dispose of this product in accordance with local and national standards and regulations.

„

Only qualified service personnel should open this device or carry out repairs.

User safety and equipment protection guidelines 

This document is intended to aid trained and competent personnel in the installation of this equipment as 
defined by the European directives for machinery, low voltage, and EMC.  Only a technician or engineer trained 
in the local and national electrical standards should perform tasks associated with the device’s electrical wiring. 

Symbol Meaning 

Description 

Danger 

The identified danger causes physical 
and property damage. 

Warning 

The identified danger can cause 
physical and property damage. 

Symbols are used to highlight 
information relating to the user’s 
personal safety and equipment 
protection throughout this document.  
When these symbols appear, the 
associated information must be read 
carefully and understood fully. 

Caution

  

Caution Use 

caution. 

„

Failure to comply with appropriate safety guidelines can result in severe personal injury or
property damage.  Always exercise proper caution when working with electrical equipment.

Содержание Unitronics IO-DI8-RO4

Страница 1: ...ing and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product in accordance with local and national standards and regulations Only qualified service personnel should open this device or carry out repairs User safety and equipment protection guidelines This document is intended to aid trained and compete...

Страница 2: ...corrosive or flammable gas moisture or rain excessive heat regular impact shocks or excessive vibration Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation Mounting the Module DIN rail mounting Snap the device onto th...

Страница 3: ...7 03 IO DI8 RO4 IO DI8 RO4 L I O Expansion Modules Unitronics Industrial Automation 3 4mm 5 8mm 0 228 85mm 3 346 80mm 3 15 68 4mm 2 693 93mm 3 66 4mm x2 0 16 0 16 ...

Страница 4: ...k all wiring before turning on the power supply Wiring Procedures Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm 2 for all wiring purposes 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire completely into the terminal to ensure that a proper connection can be made 4 Tighten enough ...

Страница 5: ...h speed Counter Reset High speed Counter Wiring the Output s Power Supply Outputs Wiring DC supply 1 Connect the positive cable to the V0 terminal and the negative to the 0V terminal A non isolated power supply can be used provided that a 0V signal is connected to the chassis Do not connect the Neutral or Line signal of the 110 220VAC to the device s 0V pin In the event of voltage fluctuations or ...

Страница 6: ...between module and OPLC Blinks when the communication link fails Inputs Number of inputs 8 in one group Input type pnp source or npn sink Galvanic isolation None Status indicators IN Green LEDs Lit when the corresponding input is active See Note 1 Nominal input voltage 24VDC for IO DI8 RO4 12VDC for IO DI8 RO4 L Input voltage IO DI8 RO4 IO DI8 RO4 L pnp source 0 5VDC for Logic 0 17 28 8VDC for Log...

Страница 7: ... L Nominal operating voltage 24VDC 12VDC Operating voltage 20 4 to 28 8VDC 10 2 to 15 6VDC Maximum current consumption 40mA 24VDC 75mA 12VDC Environmental IP20 NEMA1 Operating temperature 0 to 50 C 32 to 122 F Storage temperature 20 to 60 C 4 to 140 F Relative Humidity RH 5 to 95 non condensing Dimensions WxHxD 80mm x 93mm x 60mm 3 15 x 3 66 x 2 362 Weight 164g 5 8oz Mounting Either onto a 35mm DI...

Страница 8: ...nt nor for any use of the Unitronics products referred to herein in any manner deviating from the recommendations made in this document Unitronics assumes no responsibility for the use of any parts components or other ancillary appliances including circuitry other than as recommended hereunder or other than that embodied in the Unitronics product Unitronics retains all rights to its proprietary as...

Отзывы: